Effect of finishing technique on the microleakage and surface texture of resin-modified glass ionomer restorative materials

被引:46
|
作者
Wilder, AD
Swift, EJ
May, KN
Thompson, JY
McDougal, RA
机构
[1] Univ N Carolina, Sch Dent, Dept Operat Dent, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Sch Dent, Dept Endodont, Chapel Hill, NC 27599 USA
关键词
resin-modified glass ionomer cement; microleakage; polishing;
D O I
10.1016/S0300-5712(99)00075-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to evaluate the effects of wet and dry finishing/polishing procedures on the microleakage and surface texture of resin-modified glass ionomer (RMGI) restorative materials, Materials and methods: Class V cavity preparations were made at the cemento-enamel junction (CES) on the buccal and lingual surface of 30 extracted human molars. The teeth were restored in three groups of 10 (20 preparations in each group) using Fuji II LC and Vitremer, both RMGIs, and Fuji II a capsulated conventional glass ionomer cement (control). One restoration per tooth was finished/polished with copious applications of water and the other was finished/polished without water. All restorations were finished/polished using a sequence of four abrasive disks. Finishing/polishing was initiated according to manufacturers' instructions-immediately after light-curing Fuji II LC and Vitremer, and 15 min after placement for Fuji II. The specimens were thermocycled and subjected to a silver nitrate leakage test. Each tooth was sectioned buccolingually and examined with an optical microscope at 40 x to determine the extent of microleakage at enamel and dentin margins. The data were subjected to a non-parametric statistical analysis. To evaluate surface roughness after polishing, three disks each of Vitremer and Fuji II LC were fabricated in Teflon molds. One disk of each material was not finished/polished (control). The others were finished/polished using Sof-Lex abrasive disks. One specimen of each material was kept wet during all finishing/polishing procedures, while the other was kept dry. Atomic force microscopy was used to determine the average roughness (R-a) of the specimens. Results: For each material, microleakage at the enamel margin was very slight. Leakage of the conventional glass ionomer Fuji II was severe at dentin margins. Statistical analysis indicated that both Vitremer and Fuji II LC had significantly less leakage than Fuji II, and that Vitremer had significantly less leakage than Fuji II LC (p < 0.05). Leakage at enamel margins was significantly less than at dentin margins. Differences related to wet and dry polishing were not statistically significant. Profilometry data indicated that polished specimens were rougher than those cured against a Mylar ship. Wet polishing created greater surface roughness than dry polishing. Conclusions: RMGIs rather than conventional glass ionomers should be used in Class V cavity sites to allow immediate finishing and to reduce the incidence of microleakage. Dry finishing of RMGIs with abrasive disks is recommended because it produces a smoother surface and does not contribute to microleakage. However, wet finishing of conventional glass ionomers is still recommended to avoid desiccation. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:367 / 373
页数:7
相关论文
共 50 条
  • [1] Evaluating Dentin Surface Treatments for Resin-Modified Glass Ionomer Restorative Materials
    Imbery, T. A.
    Namboodiri, A.
    Duncan, A.
    Amos, R.
    Best, A. M.
    Moon, P. C.
    OPERATIVE DENTISTRY, 2013, 38 (04) : 429 - 438
  • [2] Surface texture of resin-modified glass ionomer cements: Effects of finishing/polishing time
    Yap, AUJ
    Ong, SB
    Yap, WY
    Tan, WS
    Yeo, JC
    OPERATIVE DENTISTRY, 2002, 27 (05) : 462 - 467
  • [3] Surface texture of resin-modified glass ionomer cements: Effects of finishing/polishing systems
    Yap, AUJ
    Tan, WS
    Yeo, JC
    Yap, WY
    Ong, SB
    OPERATIVE DENTISTRY, 2002, 27 (04) : 381 - 386
  • [4] Effect of various surface protections on the margin microleakage of resin-modified glass ionomer cements
    Chuang, SF
    Jin, YT
    Tsai, PF
    Wong, TY
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 86 (03): : 309 - 314
  • [5] Physical property investigation of contemporary glass ionomer and resin-modified glass ionomer restorative materials
    Moberg, Matthew
    Brewster, John
    Nicholson, John
    Roberts, Howard
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (03) : 1295 - 1308
  • [6] Physical property investigation of contemporary glass ionomer and resin-modified glass ionomer restorative materials
    Matthew Moberg
    John Brewster
    John Nicholson
    Howard Roberts
    Clinical Oral Investigations, 2019, 23 : 1295 - 1308
  • [7] Effects of finishing/polishing techniques on microleakage of resin-modified glass ionomer cement restorations
    Yap, AUJ
    Yap, WY
    Yeo, EJC
    Tan, JWS
    Ong, DSB
    OPERATIVE DENTISTRY, 2003, 28 (01) : 36 - 41
  • [8] Effect of cavity design on microleakage of resin-modified glass ionomer restorations
    Uno, S
    Finger, WJ
    Fritz, UB
    AMERICAN JOURNAL OF DENTISTRY, 1997, 10 (01): : 32 - 35
  • [9] Repairability of three resin-modified glass-ionomer restorative materials
    Shaffer, RA
    Charlton, DG
    Hermesch, CB
    OPERATIVE DENTISTRY, 1998, 23 (04) : 168 - 172
  • [10] Influence of lactic acid on surface microhardness of resin-modified glass ionomer restorative materials.
    Noor, M
    Toh, CG
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1352 - 1352