A simple processing method allowing comparison of renal enhancing volumes derived from standard portal venous phase contrast-enhanced multicletector CT images to derive a CT estimate of differential renal function with equivalent results to nuclear medicine quantification

被引:16
作者
Fowler, J. C.
Beadsmoore, C.
Gaskarth, M. T. G.
Cheow, H. K.
Bernal, R.
Hegarty, P.
Bullock, K. N.
Taylor, H.
Dixon, A. K.
Peters, A. M.
机构
[1] Addenbrookes Hosp, Dept Radiol, Cambridge CB2 2QQ, England
[2] Addenbrookes Hosp, Dept Nucl Med, Cambridge CB2 2QQ, England
[3] Addenbrookes Hosp, Dept Urol, Cambridge CB2 2QQ, England
[4] Univ Cambridge, Cambridge, England
关键词
D O I
10.1259/bjr/53140218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As iodinated contrast medium is cleared by glomerular filtration, it should be possible to apply the same principles utilized in radionuclide studies to derive differential renal function by comparison of enhancing renal volumes derived from contrast enhanced multidetector CT (CEMDCT). Having established a technique iteratively which appeared successful, a retrospective study was performed using 25 consecutive patients with a wide range of urological conditions who had undergone both CEMDCT, including the renal area in the portal venous phase, and nuclear medicine (NM) assessment of renal function with no urological intervention between the studies. Proprietary volume software was used to quantify the volume and attenuation of each kidney, the products of which (after subtraction of soft tissue attenuation derived from a region of interest over psoas) gave right and left enhancing renal volumes. The contribution by each kidney as a percentage of total renal enhancing tissue was derived. Comparison with NM studies resulted in excellent correlation of relative renal function by CEMDCT and NM assessments having a regression of near unity and a Pearson's correlation coefficient of 0.96. Bland Altman and Passing Bablock tests confirmed good agreement between the two methods with no bias. This is a simple, practicable processing technique using standard portal venous phase CEMDCT images to quantify differential function. This technique may allow a one-stop CT assessment of both anatomy and function.
引用
收藏
页码:935 / 942
页数:8
相关论文
共 10 条
[1]   Split renal function in patients with suspected renal artery stenosis:: A comparison between gamma camera renography and two methods of measurement with computed tomography [J].
Björkman, H ;
Eklöf, H ;
Wadström, J ;
Andersson, LG ;
Nyman, R ;
Magnusson, A .
ACTA RADIOLOGICA, 2006, 47 (01) :107-113
[2]  
DAWSON P, 1993, INVEST RADIOL, V28, pS79
[3]   Contrast enhanced spiral computerized tomography in live kidney donors: A single session for anatomical and functional assessment [J].
El-Diasty, TA ;
Shokeir, AA ;
El-Ghar, MEA ;
Gad, HM ;
Refaie, AF ;
El-Din, ABS .
JOURNAL OF UROLOGY, 2004, 171 (01) :31-34
[4]   Contrast enhanced spiral computerized tomography in patients with chronic obstructive uropathy and normal serum creatinine: A single session for anatomical and functional assessment [J].
El-Ghar, MEA ;
Shokeir, AA ;
El-Diasty, T ;
Refaie, HF ;
Gad, HM ;
El-Dein, ABS .
JOURNAL OF UROLOGY, 2004, 172 (03) :985-988
[5]   Use of spiral CT and the contrast medium iohexol to determine in one session aortorenal morphology and the relative glomerular filtration rate of each kidney [J].
Frennby, B ;
Almén, T .
EUROPEAN RADIOLOGY, 2001, 11 (11) :2270-2277
[6]   CT derived Patlak images of the human kidney [J].
Miles, KA ;
Leggett, DAC ;
Bennett, GAJ .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (854) :153-158
[7]   Measuring split renal function in renal donors:: Can computed tomography replace renography? [J].
Nilsson, H ;
Wadström, J ;
Andersson, LG ;
Raland, H ;
Magnusson, A .
ACTA RADIOLOGICA, 2004, 45 (04) :474-480
[8]   Functional CT of the kidney [J].
Tsushima, Y .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 30 (03) :191-197
[9]   Use of contrast-enhanced computed tomography to measure clearance per unit renal volume: A novel measurement of renal function and fractional vascular volume [J].
Tsushima, Y ;
Blomley, MJK ;
Kusano, S ;
Endo, K .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1999, 33 (04) :754-760
[10]   Ultrasound measured renal length versus low dose CT volume in predicting single kidney glomerular filtration rate [J].
Widjaja, E ;
Oxtoby, JW ;
Hale, TL ;
Jones, PW ;
Harden, PN ;
McCall, IW .
BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (921) :759-764