Modeling granular phosphor screens by Monte Carlo methods

被引:77
|
作者
Liaparinos, Panagiotis F. [1 ]
Kandarakis, Ioannis S.
Cavouras, Dionisis A.
Delis, Harry B.
Panayiotakis, George S.
机构
[1] Univ Patras, Fac Med, Dept Phys Med, Patras 26500, Greece
[2] Inst Educ Technol, Dept Med Instruments Technol, Athens 12210, Greece
关键词
x-ray imaging; phosphor screens; Monte Carlo; modeling; MTF;
D O I
10.1118/1.2372217
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The intrinsic phosphor properties are of significant importance for the performance of phosphor screens used in medical imaging systems. In previous analytical-theoretical and Monte Carlo studies on granular phosphor materials, values of optical properties, and light interaction cross sections were found by fitting to experimental data. These values were then employed for the assessment of phosphor screen imaging performance. However, it was found that, depending on the experimental technique and fitting methodology, the optical parameters of a specific phosphor material varied within a wide range of values, i.e., variations of light scattering with respect to light absorption coefficients were often observed for the same phosphor material. In this study, x-ray and light transport within granular phosphor materials was studied by developing a computational model using Monte Carlo methods. The model was based on the intrinsic physical characteristics of the phosphor. Input values required to feed the model can be easily obtained from tabulated data. The complex refractive index was introduced and microscopic probabilities for light interactions were produced, using Mie scattering theory. Model validation was carried out by comparing model results on x-ray and light parameters (x-ray absorption, statistical fluctuations in the x-ray to light conversion process, number of emitted light photons, output light spatial distribution) with previous published experimental data on Gd2O2S : Tb phosphor material (Kodak Min-R screen). Results showed the dependence of the modulation transfer function (MTF) on phosphor grain size and material packing density. It was predicted that granular Gd2O2S : Tb screens of high packing density and small grain size may exhibit considerably better resolution and light emission properties than the conventional Gd2O2S : Tb screens, under similar conditions (x-ray incident energy, screen thickness). (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4502 / 4514
页数:13
相关论文
共 50 条
  • [1] MONTE-CARLO OPTIMIZATION OF METAL PHOSPHOR SCREENS AT MEGAVOLTAGE ENERGIES
    RADCLIFFE, T
    BARNEA, G
    WOWK, B
    RAJAPAKSHE, R
    SHALEV, S
    MEDICAL PHYSICS, 1993, 20 (04) : 1161 - 1169
  • [2] Evaluation of high packing density powder X-ray screens by Monte Carlo methods
    Liaparinos, P.
    Kandarakis, I.
    Cavouras, D.
    Kalivas, N.
    Delis, H.
    Panayiotakis, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) : 427 - 429
  • [3] Monte Carlo modeling of storage phosphor plate readouts
    Fasbender, R
    Li, H
    Winnacker, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 512 (03) : 610 - 618
  • [4] Measurement and Monte Carlo modeling of the spatial response of scintillation screens
    Pistrui-Maximean, S. A.
    Letang, J. M.
    Freud, N.
    Koch, A.
    Walenta, A. H.
    Montarou, G.
    Babot, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (03) : 719 - 727
  • [5] Monte Carlo methods
    Kroese, Dirk P.
    Rubinstein, Reuven Y.
    WILEY INTERDISCIPLINARY REVIEWS-COMPUTATIONAL STATISTICS, 2012, 4 (01) : 48 - 58
  • [6] HYBRID MONTE CARLO/DETERMINISTIC METHODS FOR ACCELERATING ACTIVE INTERROGATION MODELING
    Peplow, Douglas E.
    Miller, Thomas M.
    Patton, Bruce W.
    Wagner, John C.
    NUCLEAR TECHNOLOGY, 2013, 182 (01) : 63 - 74
  • [7] Reliability and Accuracy of Bootstrap and Monte Carlo Methods for Demand Distribution Modeling
    Razu, Swithin S.
    Takai, Shun
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2011, VOL 9, 2012, : 781 - 787
  • [8] Quasi-Monte Carlo methods - Applications to modeling of light transport in tissue
    Schafer, SA
    LASER-TISSUE INTERACTION VII, PROCEEDINGS OF, 1996, 2681 : 317 - 324
  • [9] Monte Carlo study on the imaging performance of powder Lu2SiO5:: Ce phosphor screens under x-ray excitation:: Comparison with Gd2O2S:Tb screens
    Liaparinos, Panagiotis F.
    Kandarakis, Ioannis S.
    Cavouras, Dionisis A.
    Delis, Harry B.
    Panayiotakis, George S.
    MEDICAL PHYSICS, 2007, 34 (05) : 1724 - 1733
  • [10] Monte Carlo Modeling of Asphaltene Aggregation Coupled with Sedimentation
    Safaie, Kian
    Nazar, Ali Reza Solaimany
    JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2013, 34 (08) : 1173 - 1182