Discussion on Water Condensation in Membrane Pores during CO2 Absorption at High Temperature

被引:6
|
作者
Chan, Zhe Phak [1 ,2 ]
Li, Lin [1 ]
Kang, Guodong [3 ]
Ab Manan, Norfaizah [2 ]
Cao, Yiming [3 ]
Wang, Tonghua [1 ]
机构
[1] Dalian Univ Technol, Sch Chem Engn, Dalian 116023, Peoples R China
[2] PETRONAS Res Sdn Bhd, Bangi 43000, Malaysia
[3] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian Natl Lab Clean Energy, Dalian 116023, Peoples R China
基金
中国国家自然科学基金;
关键词
capillary condensation; membrane contactor; CO2; absorption; membrane wetting; high temperature; NATURAL-GAS; WETTING PHENOMENA; CONTACTORS; REMOVAL; PARAMETERS; CAPTURE; DISTILLATION; PERFORMANCE; NUCLEATION;
D O I
10.3390/membranes10120407
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Water condensation is a possible cause of membrane wetting in the operation of membrane contactors, especially under high-temperature conditions. In this study, water condensation in pores of polytetrafluoroethylene (PTFE) hollow fiber membranes was investigated during high-pressure CO2 absorption around 70 degrees C. It was found that the liquid accumulation rate in the treated gas knock-out drum was constant during continuous operation for 24 h when all experimental conditions were fixed, indicating a stable degree of membrane wetting. However, as the operating parameters were changed, the equilibrium vapor pressure of water within membrane pores could change, which may result in a condensation-conducive environment. Water condensation in membrane pores was detected and proven indirectly through the increase in liquid accumulation rate in the treated gas knock-out drum. The Hagen-Poiseuille equation was used to correlate the liquid accumulation rate with the degree of membrane wetting. The degree of membrane wetting increased significantly from 1.8 x 10(-15) m(3) to 3.9 x 10(-15) m(3) when the feed gas flow rate was reduced from 1.45 kg/h to 0.40 kg/h in this study due to water condensation in membrane pores. The results of this study provide insights into potential operational limitations of membrane contactor for CO2 absorption under high-temperature conditions.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [1] Modeling of CO2 absorption in a membrane contactor considering solvent evaporation
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Rahim, Nihmiya Abdul
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 110 : 1 - 10
  • [2] A developed asymmetric PVDF hollow fiber membrane structure for CO2 absorption
    Mansourizadeh, Amir
    Ismail, Ahmad Fauzi
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (02) : 374 - 380
  • [3] Modelling the effect of CO2 loading of aqueous potassium glycinate on CO2 absorption in a membrane contactor
    Nieminen, Harri
    Maksimov, Pavel
    Laari, Arto
    Koiranen, Tuomas
    FRONTIERS IN CHEMICAL ENGINEERING, 2022, 4
  • [4] Effects of water condensation on hollow fiber membrane contactor performance for CO2 capture by absorption into a chemical solvent
    Villeneuve, Kevin
    Hernandez, Alicia Andrea Torres
    Zaidiza, David Albarracin
    Roizard, Denis
    Rode, Sabine
    JOURNAL OF MEMBRANE SCIENCE, 2018, 556 : 365 - 373
  • [5] Membrane absorption using ionic liquid for pre-combustion CO2 capture at elevated pressure and temperature
    Dai, Zhongde
    Deng, Liyuan
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2016, 54 : 59 - 69
  • [6] CO2 Absorption Using Hollow Fiber Membrane Contactors: Introducing pH Swing Absorption (pHSA) to Overcome Purity Limitation
    Chavan, Sayali Ramdas
    Perre, Patrick
    Pozzobon, Victor
    Lemaire, Julien
    MEMBRANES, 2021, 11 (07)
  • [7] Fabrication of hydrophobic ZIFs based composite membrane with high CO2 absorption performance
    Xu, Li
    Qin, Yu
    Liu, Liying
    Xiao, Juntian
    Ding, Zhongwei
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2021, 38 (05) : 1032 - 1042
  • [8] Removal of high concentration CO2 from natural gas using high pressure membrane contactors
    Kang, Guodong
    Chan, Zhe Phak
    Saleh, Syafiqa Bt M.
    Cao, Yiming
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2017, 60 : 1 - 9
  • [9] Improvement of mass transfer by renewing the stagnant liquid within membrane pores during membrane absorption process
    Zhang, Lifang
    Sun, Qing
    Ming, Fengjun
    Guo, Qingwen
    Zhang, Weidong
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 368
  • [10] Modeling and simulation of the hollow fiber bore size on the CO2 absorption in membrane contactor
    Ghasem, Nayef
    CHEMICAL PRODUCT AND PROCESS MODELING, 2020, 15 (04):