High-pressure balloon catheter for real-time pressure monitoring in the Esophagus

被引:0
作者
Kwan, KY [1 ]
Kaler, KVIS [1 ]
Mintchev, M [1 ]
机构
[1] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
来源
ICES 2002: 9TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS I-111, CONFERENCE PROCEEDINGS | 2002年
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper reports the development of a new catheter for esophageal manometry, implemented by connecting a miniature high-pressure sensing balloon to an external pressure sensor. The integration of the catheter into a signal conditioning and data acquisition system for real-time pressure monitoring is also described. In order to characterize the sensitivity of the novel self-contained air balloon design, experimental setup for simulating the esophageal motility was utilized. The results show that the self-contained air balloon catheter is suitable for measuring various waveforms typical to the ones generated in esophageal motility pathologies.
引用
收藏
页码:1211 / 1214
页数:4
相关论文
共 50 条
[21]   Real-Time Downhole Monitoring and Logging Reduced Mud Loss Drastically for High-Pressure Gas Wells in Tarim Basin, China [J].
Wang ShunChang ;
Jiang YiMing ;
Zheng ChunJiang ;
Wu BaiLin ;
Zheng XinQuan ;
Tang JiPing ;
Yu JinHai ;
Fan HongHai .
SPE DRILLING & COMPLETION, 2010, 25 (02) :187-192
[22]   Real-time downhole monitoring and logging reduced mud loss drastically for high-pressure gas wells in Tarim basin, China [J].
ShunChang W. ;
YiMing J. ;
ChunJiang Z. ;
BaiLin W. ;
XinQuan Z. ;
JiPing T. ;
JinHai Y. ;
HongHai F. .
SPE Drilling and Completion, 2010, 25 (02) :187-192
[23]   A REAL-TIME PRESSURE ALGORITHM [J].
KINIAS, P ;
FOZZARD, HA ;
NORUSIS, MJ .
COMPUTERS IN BIOLOGY AND MEDICINE, 1981, 11 (04) :211-220
[24]   A Wireless Power-Free Pressure Sensor for Real-Time In Vivo Gastrointestinal Pressure Monitoring [J].
Shi, Qiang ;
Chen, Deyong ;
Wang, Junbo ;
Bao, Kaikai ;
Liu, Lijuan .
MICRO-NANO TECHNOLOGY XV, 2014, 609-610 :993-996
[25]   Flexible Seven-in-One Microsensor Embedded in High-Pressure Proton Exchange Membrane Water Electrolyzer for Real-Time Microscopic Monitoring [J].
Lee, Chi-Yuan ;
Chen, Chia-Hung ;
Chuang, Hsian-Chun ;
Chen, Shan-Yu ;
Chiang, Yu-Chen .
SENSORS, 2023, 23 (12)
[26]   THE HYPOGANGLIONIC AND AGANGLIONIC HIGH-PRESSURE ZONE AT THE MOUTH OF THE ESOPHAGUS [J].
STELZNER, F ;
LIERSE, W ;
MANNFRAHS, F .
LANGENBECKS ARCHIV FUR CHIRURGIE, 1986, 367 (03) :187-196
[27]   Testbed for Real-time Monitoring of Leak in Low Pressure Gas Pipeline [J].
Mishra, Himanshu ;
Karkulali, Pugalenthi ;
Ukil, Abhisek ;
Dauwels, Justin .
PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, :459-462
[28]   Real-Time Monitoring of Blood Flow and Intravesical Pressure in the Rat Bladder [J].
Saito, Motoaki ;
Ohmasa, Fumiya ;
Tsounapi, Panagiota ;
Inoue, Seiya ;
Kinoshita, Yukako ;
Dimitriadis, Fotios ;
Satoh, Keisuke .
LUTS-LOWER URINARY TRACT SYMPTOMS, 2011, 3 (02) :76-78
[29]   Real-time sitting posture monitoring system using pressure sensor [J].
Jung, Hwa-Young ;
Ji, Jun-Keun ;
Min, Se Dong .
Transactions of the Korean Institute of Electrical Engineers, 2015, 64 (06) :940-947
[30]   Sound pressure level real-time monitoring of outdoor directional noise [J].
Chen, Yong ;
Wu, Ming ;
Lu, Ling ;
Fang, Xing ;
Yang, Jun .
APPLIED ACOUSTICS, 2023, 202