Outcomes and satisfaction rates for the redesigned 2-piece penile prosthesis

被引:65
作者
Lux, Matthew
Reyes-Vallejo, Luis
Morgentaler, Abraham
Levine, Laurence A.
机构
[1] Harvard Univ, Beth Israel Deaconess Med Ctr, Sch Med, Boston, MA 02215 USA
[2] Rush Univ, Chicago, IL 60612 USA
关键词
penis; impotence; prostheses and implants; questionnaires; patient satisfaction;
D O I
10.1016/j.juro.2006.08.094
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We evaluated long-term viability, quality of life and satisfaction with the redesigned 2 piece Ambicor (R) inflatable penile prosthesis. This device underwent revision of the rear tip extender and reinforcement of the pump tubing connection to decrease fluid leak failure in 1998. Materials and Methods: In this retrospective analysis we evaluated 146 men with erectile dysfunction at 2 centers who underwent device implantation between June 1999 and October 2004 with the redesigned prosthesis. Patient information forms were completed, including patient history, surgical information and revision data. Patients were mailed a modified Erectile Dysfunction Inventory of Treatment Satisfaction questionnaire, a modified Erectile Dysfunction Inventory of Treatment Satisfaction Partner survey and a questionnaire regarding pertinent inflatable penile prosthesis questions. Results: A total of 146 men with a mean age of 58.7 years (range 25 to 78) were evaluated after inflatable penile prosthesis placement. Time from implant to followup was 3 to 73 months (mean 38). Only 1 device (0.7%) was removed due to infection. One implant (0.7%) was replaced due to fluid loss and 1 (0.7%) was revised due to improper sizing. Kaplan-Meier life table analysis indicated that the percent of patients free from reoperation was 99.2% at 12 months, 99.2% at 36 months and 91% at 48 months or greater. Of the 101 subjects completing the survey the average patient used the prosthesis 5 times monthly and 88.9% reported continued use. Of the patients 91% said that it was easy to use and 95% had little to no trouble learning to use it, while 84% stated that the inflatable penile prosthesis provided good to excellent rigidity for coitus. Overall patient and partner satisfaction was 85% and 76%, respectively. Of the patients 86% said that they would recommend the prosthesis to friends or if need be undergo the procedure again. Conclusions: The redesigned Ambicor 2-piece penile prosthesis appears to be safe and effective. It is associated with a low rate of revision as well as high patient and partner satisfaction.
引用
收藏
页码:262 / 266
页数:5
相关论文
共 18 条
[1]   EDITS: Development of questionnaires for evaluating satisfaction with treatments for erectile dysfunction [J].
Althof, SE ;
Corty, EW ;
Levine, SB ;
Levine, F ;
Burnett, AL ;
McVary, K ;
Stecher, V ;
Seftel, AD .
UROLOGY, 1999, 53 (04) :793-799
[2]   Efficacy, safety and patient satisfaction outcomes of the AMS 700CX inflatable penile prosthesis: Results of a long-term multicenter study [J].
Carson, CC ;
Mulcahy, JJ ;
Govier, FE .
JOURNAL OF UROLOGY, 2000, 164 (02) :376-380
[3]   Efficacy of antibiotic impregnation of inflatable penile prostheses in decreasing infection in original implants [J].
Carson, CC .
JOURNAL OF UROLOGY, 2004, 171 (04) :1611-1614
[4]   Long-term mechanical reliability of AMS 700 series inflatable penile prostheses: Comparison of CX/CXM and Ultrex cylinders [J].
Daitch, JA ;
Angermeier, KW ;
Lakin, MM ;
Ingleright, BJ ;
Montague, DK .
JOURNAL OF UROLOGY, 1997, 158 (04) :1400-1402
[5]   Efficacy of anti microbial-impregnated silicone sections from penile implants in preventing device colonization in an animal model [J].
Darouiche, RO ;
Mansouri, MD ;
Raad, II .
UROLOGY, 2002, 59 (02) :303-307
[6]   Long-term mechanical reliability of multicomponent inflatable penile prosthesis: Comparison of device survival [J].
Dubocq, F ;
Tefilli, MV ;
Gheiler, EL ;
Li, HK ;
Dhabuwala, CB .
UROLOGY, 1998, 52 (02) :277-281
[7]   Safety and efficacy outcome of mentor alpha-1 inflatable penile prosthesis implantation for impotence treatment [J].
Goldstein, I ;
Newman, L ;
Baum, N ;
Brooks, M ;
Chaikin, L ;
Goldberg, K ;
McBride, A ;
Krane, RJ .
JOURNAL OF UROLOGY, 1997, 157 (03) :833-839
[8]   Mechanical reliability, surgical complications, and patient and partner satisfaction of the modern three-piece inflatable penile prosthesis [J].
Govier, FE ;
Gibbons, RP ;
Correa, RJ ;
Pritchett, TR ;
Kramer-Levien, D .
UROLOGY, 1998, 52 (02) :282-286
[9]   Antimicrobial activity of antibiotic-soaked, Resist™-coated Bioflex® [J].
Hellstrom, WJG ;
Hyun, JS ;
Human, L ;
Sanabria, J ;
Bivalacqua, T ;
Leungwattanakij, S .
INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2003, 15 (01) :18-21
[10]  
Khoudary KP, 1997, J LONG-TERM EFF MED, V7, P55