Leadless Permanent Pacing: A Single Centre Australian Experience

被引:3
作者
Denman, Russell A. [1 ]
Lee, Adam C. [1 ,2 ]
Mengel, Caleb [1 ,2 ]
Townsend, Simon [1 ]
Betts, John [1 ]
Bovey, Nicole [1 ]
Wright, Daniel [1 ]
Davison, Oscar [1 ]
Haqqani, Haris M. [1 ,2 ]
机构
[1] Prince Charles Hosp, Dept Cardiol, Brisbane, Qld, Australia
[2] Univ Queensland, Fac Med, Brisbane, Qld, Australia
关键词
Bradycardia; Heart block; Leadless pacemaker; Atrial fibrillation; PACEMAKER THERAPY; COMPLICATIONS; PERFORMANCE;
D O I
10.1016/j.hlc.2018.09.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background To describe the performance and clinical outcomes of consecutive patients having a leadless pacemaker (LP) implanted at a single institution. Methods Clinical data and device parameters were prospectively collected on all patients undergoing LP implantation from November 2015 to April 2018. Results A total of 79 patients (52 male), median age of 78 years, was included. Leadless pacemaker implantation was successful in 76 patients (96%). Implantation failed in two patients due to excessive venous tortuosity and due to inadequate sensing in another. Seventy-three (73) patients (96%) had chronic atrial fibrillation and all had a Class I or II indication for pacing. Procedure time was 29 minutes (IQR 21-43) and fluoroscopy time was 8 minutes (IQR 5-13). The median R wave at implant was 11.2 mV (IQR 6.9-15.0). The median capture threshold at 0.24 ms was 0.5 V (IQR 0.4-0.9) and impedance was 754 SZ (IQR 680-880). Intraprocedural acute dislodgement occurred in one patient following cutting of the tether but successful snaring and reimplantation was performed. During a median follow-up of 355 days (range 9-905), overall electrical performance has been excellent. No patients have been readmitted for device revision or complications. Five (5) patients (7%) died during follow-up from unrelated causes. Conclusions Leadless pacemakers can be implanted safely and effectively in the majority of patients. Device electrical performance was excellent over a median follow-up of 12 months.
引用
收藏
页码:1677 / 1682
页数:6
相关论文
共 16 条
  • [1] Techniques for successful early retrieval of the Micra transcatheter pacing system: A worldwide experience
    Afzal, Muhammad R.
    Daoud, Emile G.
    Cunnane, Ryan
    Mulpuru, Shiva K.
    Koay, Alan
    Hussain, Azlan
    Omar, Razali
    Wei, Koh Kok
    Amin, Anish
    Kidwell, Gregory
    Patel, Nirav
    Love, Charles
    Lloyd, Michael
    Sterlinski, Maciej
    Goldbarg, Seth
    Leal, Miguel A.
    Gabriels, James
    Patel, Apoor
    Jadonath, Ram
    Grubman, Eric
    Crossley, George
    Pepper, Chris
    Lakkireddy, Dhanunjaya
    Okabe, Toshimasa
    Hummel, John D.
    Augostini, Ralph S.
    [J]. HEART RHYTHM, 2018, 15 (06) : 841 - 846
  • [2] Accelerometer-based atrioventricular synchronous pacing with a ventricular leadless pacemaker: Results from the Micra atrioventricular feasibility studies
    Chinitz, Larry
    Ritter, Philippe
    Khelae, Surinder Kaur
    Iacopino, Saverio
    Garweg, Christophe
    Grazia-Bongiorni, Maria
    Neuzil, Petr
    Johansen, Jens Brock
    Mont, Lluis
    Gonzalez, Efrain
    Sagi, Venkata
    Duray, Gabor Z.
    Clementy, Nicolas
    Sheldon, Todd
    Splett, Vincent
    Stromberg, Kurt
    Wood, Nicole
    Steinwender, Clemens
    [J]. HEART RHYTHM, 2018, 15 (09) : 1363 - 1371
  • [3] Long-term performance of a transcatheter pacing system: 12-Month results from the Micra Transcatheter Pacing Study
    Duray, Gabor Z.
    Ritter, Philippe
    El-Chami, Mikhael
    Narasimhan, Calambur
    Omar, Razali
    Tolosana, Jose M.
    Zhang, Shu
    Soejima, Kyoko
    Steinwender, Clemens
    Rapallini, Leonardo
    Cicic, Aida
    Fagan, Dedra H.
    Liu, Shufeng
    Reynolds, Dwight
    [J]. HEART RHYTHM, 2017, 14 (05) : 702 - 709
  • [4] Issa Z, 2015, HEART RHYTHM, V12, pS176
  • [5] Complications related to permanent pacemaker therapy
    Kiviniemi, MS
    Pirnes, MA
    Eränen, HJK
    Kettunen, RVJ
    Hartikainen, JEK
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (05): : 711 - 720
  • [6] The 11th World Survey of Cardiac Pacing and Implantable Cardioverter-Defibrillators: Calendar Year 2009-A World Society of Arrhythmia's Project
    Mond, Harry G.
    Proclemer, Alessandro
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (08): : 1013 - 1027
  • [7] Right Ventricular Anatomy Can Accommodate Multiple Micra Transcatheter Pacemakers
    Omdahl, Pamela
    Eggen, Michael D.
    Bonner, Matthew D.
    Iaizzo, Paul A.
    Wika, Kent
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (04): : 393 - 397
  • [8] Complications of pacemaker therapy in adults with congenital heart disease: A multicenter study
    Opic, Petra
    van Kranenburg, Matthijs
    Yap, Sing-Chien
    van Dijk, Arie P.
    Budts, Werner
    Vliegen, Hubert W.
    van Erven, Lieselot
    Can, Anil
    Sahin, Gulhan
    Theuns, Dominic A. M. J.
    Witsenburg, Maarten
    Roos-Hesselink, Jolien W.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 3212 - 3216
  • [9] Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker
    Reddy, Vivek Y.
    Exner, Derek V.
    Cantillon, Daniel J.
    Doshi, Rahul
    Bunch, T. Jared
    Tomassoni, Gery F.
    Friedman, Paul A.
    Estes, N. A. Mark, III
    Ip, John
    Niazi, Imran
    Plunkitt, Kenneth
    Banker, Rajesh
    Porterfield, James
    Ip, James E.
    Dukkipati, Srinivas R.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2015, 373 (12) : 1125 - 1135
  • [10] Permanent Leadless Cardiac Pacing Results of the LEADLESS Trial
    Reddy, Vivek Y.
    Knops, Reinoud E.
    Sperzel, Johannes
    Miller, Marc A.
    Petru, Jan
    Simon, Jaroslav
    Sediva, Lucie
    de Groot, Joris R.
    Tjong, Fleur V. Y.
    Jacobson, Peter
    Ostrosff, Alan
    Dukkipati, Srinivas R.
    Koruth, Jacob S.
    Wilde, Arthur A. M.
    Kautzner, Josef
    Neuzil, Petr
    [J]. CIRCULATION, 2014, 129 (14) : 1466 - 1471