Optimization of solid-phase microextraction of volatile phenols in water by a polyaniline-coated Pt-fiber using experimental design

被引:82
作者
Mousavi, M.
Noroozian, E.
Jalali-Heravi, A.
Mollahosseini, A.
机构
[1] Shahid Bahonar Univ Kerman, Dept Chem, Kerman, Iran
[2] Sharif Univ Technol, Dept Chem, Tehran, Iran
关键词
experimental design; chemometrics; solid-phase microextraction; polyaniline; gas chromatography; phenols;
D O I
10.1016/j.aca.2006.08.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-phase microextraction (SPME) coupled to gas chromatography (GC) was applied to the extraction of phenol and some of its volatile derivatives in water samples. The SPME fiber consisted of a thin layer of polyaniline, which was electrochemically coated on a fine Pt wire. The stability of the coating was such that it could be used at temperatures as high as 325 degrees C, without any deterioration. The effects of various parameters affecting the extraction efficiency were studied, simultaneously. From these, optimization of the extraction temperature, extraction time, coating thickness, sample pH, salt concentration and desorption time was carried out by means of a (2(6-2)) fractional factorial design. It was found that the effects and interactions of five out of six factors were significant. However, the coating thickness showed a large main effect but an insignificant interaction effect, so it was kept constant. Also, the effect of desorption time was insignificant if sufficient time was allowed for desorption to take place. Therefore, a central composite design (CCD) with four remaining factors, i.e., sample pH, salt concentration, extraction time and sample temperature was performed and a response surface equation was derived. The statistical parameters of the derived model were r=0.97 and F=25.3. The optimum conditions were obtained using a grid method. Using the optimum conditions, the method was analytically evaluated. The detection limit, relative standard deviation, linear range and recovery were 1.3-12.8 ng mL(-1), 2.2-5.3%, 0.01-5.0 mu g mL(-1), and 88-103%, respectively. The results showed the suitability of polyaniline-coated fiber in analyzing volatile phenolic compounds in water samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 77
页数:7
相关论文
共 36 条
[1]  
[Anonymous], 1995, 8041 EPA US EPA, P1
[2]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[3]   An electropolymerized aniline-based fiber coating for solid phase microextraction of phenols from water [J].
Bagheri, H ;
Mir, A ;
Babanezhad, E .
ANALYTICA CHIMICA ACTA, 2005, 532 (01) :89-95
[4]  
Belardi R.P., 1989, WATER POLLUT RES J C, V24, P179, DOI [10.2166/wqrj.1989.010, DOI 10.2166/WQRJ.1989.010]
[5]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[6]   THE ORIGIN OF ETHYLPHENOLS IN WINES [J].
CHATONNET, P ;
DUBOURDIEU, D ;
BOIDRON, JN ;
PONS, M .
JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1992, 60 (02) :165-178
[7]  
COHEN JD, 1992, Patent No. 5135682
[8]  
De Santis D, 1999, ITAL J FOOD SCI, V11, P371
[9]   Solid-phase microextraction of aliphatic alcohols based on polyaniline coated fibers [J].
Djozan, D ;
Bahar, S .
CHROMATOGRAPHIA, 2004, 59 (1-2) :95-99
[10]   Monitoring of phenol and 4-chlorophenol in petrochemical sewage using solid-phase microextraction and capillary gas chromatography [J].
Djozan, D ;
Bahar, S .
CHROMATOGRAPHIA, 2003, 58 (9-10) :637-642