Study of the lightning damage produced in a full-locked wire rope of an aerial cableway

被引:5
作者
Fontanari, Vigilio [1 ]
Menapace, Cinzia [1 ]
Pedrotti, Ettore [2 ]
机构
[1] Univ Trento, Dept Ind Engn, Via Sommarive 9, I-38123 Trento, Italy
[2] Lab Tecnol Impianti Fune Latif, Via Provina 24, I-38123 Trento, Italy
关键词
Lightning damage; Full locked wire rope; Electric arc; Graded microstructure; Hyper-quenching; STEEL; MECHANISMS;
D O I
10.1016/j.engfailanal.2019.05.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The ropes of aerial cableways are directly exposed to atmospheric agents that can detrimentally influence their 'in service' behaviour with dangerous consequences on the whole installation. The lightning strike represents one of the most feared events, since during electric discharge transient a large amount of energy is transferred to the structural parts of the rope in very short time intervals, thus determining a localized thermal shock for the material invested by the electric arc. The local damage effects are clearly identifiable by visual inspection and usually require the substitution of the wire rope. In this paper we investigate the effects of a lightning strike occurred to the carrying rope of a high altitude aerial cableway (Pejo 3000), installed on the Italian side of the Alps. During a periodic visual inspection, an important localized damage in the rope produced by lightning was observed. After an initial attempt to repair it, the rope was dismantled. The damaged section was cut and the wires were subjected to microstructural analysis, static mechanical characterization and finally fractographic observation. The aim was to shed light on the entity of the damage produced by the lightning flashover in order to evaluate the potential danger of this event since, generally, the cableway is not immediately inspected if the atmospheric event does not assume the character of exceptionality. The detailed study of the metallurgical modifications and the measurement of the mechanical deterioration of single wires highlight the microstructural nature of the damage, the strong directionality of the thermal shock effects and the localization of the damage in the external layer of the full locked rope.
引用
收藏
页码:530 / 539
页数:10
相关论文
共 22 条
[1]  
[Anonymous], 2012, 10218 UNI EN
[2]  
[Anonymous], 2012, 1026412012 UNI EN
[3]   Ruptures in overhead ground wire - Transmission line 220 kV [J].
Arias Velasquez, Ricardo Manuel ;
Mejia Lara, Jennifer Vanessa .
ENGINEERING FAILURE ANALYSIS, 2018, 87 :1-14
[4]  
Atkins M., 1980, ATLAS CONTINUOUS COO
[5]  
Batti P., 1982, METALL ITAL, V1, P32
[6]   Fatigue strength and surface quality of eutectoid steel wires [J].
Beretta, S ;
Boniardi, M .
INTERNATIONAL JOURNAL OF FATIGUE, 1999, 21 (04) :329-335
[7]   Cold-drawn pearlitic steel wires [J].
Borchers, Christine ;
Kirchheim, Reiner .
PROGRESS IN MATERIALS SCIENCE, 2016, 82 :405-444
[8]   FAILURE MECHANISMS IN WIRE ROPES [J].
CHAPLIN, CR .
ENGINEERING FAILURE ANALYSIS, 1995, 2 (01) :45-57
[9]  
Cicolini L., 2004, 3 ISR INT SEILBAHN R, P8
[10]   Fire behavior of steel wire ropes: Experimental investigation and numerical analysis [J].
Fontanari, V. ;
Benedetti, M. ;
Monelli, B. D. ;
Degasperi, F. .
ENGINEERING STRUCTURES, 2015, 84 :340-349