Partial least squares modeling of combined infrared, 1H NMR and 13C NMR spectra to predict long residue properties of crude oils

被引:33
作者
de Peinder, Peter [1 ,3 ]
Visser, Tom [3 ]
Petrauskas, Derek D. [2 ]
Salvatori, Fabien [2 ]
Soulimani, Fouad [3 ]
Weckhuysen, Bert M. [3 ]
机构
[1] VibSpec, NL-4006 XL Tiel, Netherlands
[2] Shell Global Solut Int BV, The Hague, Netherlands
[3] Univ Utrecht, Dept Chem, Inorgan Chem & Catalysis Grp, NL-3584 CA Utrecht, Netherlands
关键词
Bitumen; PLS; Property prediction; Chemometrics; SYNCRUDE SWEET BLEND; STRUCTURAL GROUP-ANALYSIS; RAMAN-SPECTROSCOPY; DISTILLATION FRACTIONS; CHEMOMETRIC ANALYSIS; IR SPECTROSCOPY; BITUMEN; PETROLEUM; CALIBRATION; ORIGIN;
D O I
10.1016/j.vibspec.2009.04.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Research has been carried out to determine the potential of partial least squares (PLS) modeling of mid-infrared (IR) spectra of crude oils combined with the corresponding H-1 and C-13 nuclear magnetic resonance (NMR) data, to predict the long residue (LR) properties of these substances. The study elaborates further on a recently developed and patented method to predict this type of information from only IR spectra. In the present study, PLS modeling was carried out for 7 different LR properties, i.e., yield long-on-crude (YLC), density (D-LR), Viscosity (V-LR), sulfur content (S), pour point (PP), asphaltenes (Asph) and carbon residue (CR). Research was based on the spectra of 48 crude oil samples of which 28 were used to build the PLS models and the remaining 20 for validation. For each property, PUS modeling was carried out on single type IR, C-13 NMR and H-1 NMR spectra and on 3 sets of merged spectra, i.e., IR + H-1 NMR, IR + C-13 NMR and IR + H-1 NMR + C-13 NMR. The merged spectra were created by considering the NMR data as a scaled extension of the IR spectral region. In addition, PLS modeling of coupled spectra was performed after a Principal Component Analysis (PCA) of the IR, C-13 NMR and H-1 NMR calibration sets. For these models, the 10 most relevant PCA scores of each set were concatenated and scaled prior to PLS modeling. The validation results of the individual IR models, expressed as root-mean-square-error-of-prediction (RMSEP) values, turned out to be slightly better than those obtained for the models using single input C-13 NMR or H-1 NMR data. For the models based on IR spectra combined with NMR data, a significant improvement of the RMSEP values was not observed neither for the models based on merged spectra nor for those based on the PCA scores. It implies, that the commonly accepted complementary character of NMR and IR is, at least for the crude oil and bitumen samples under study, not reflected in the results of PLS modeling. Regarding these results, the absence of sample preparation and the straightforward way of data acquisition, IR spectroscopy is preferred over NMR for the prediction of LR properties of crude oils at site. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 56 条
[1]   Prediction of source rock origin by chemometric analysis of Fourier transform infrared-attenuated total reflectance spectra of oil petroleum: Evaluation of aliphatic and aromatic fractions by self-modeling mixture analysis [J].
Abbas, O ;
Dupuy, N ;
Rebufa, C ;
Vrielynck, L ;
Kister, J ;
Permanyer, A .
APPLIED SPECTROSCOPY, 2006, 60 (03) :304-314
[2]  
Adedosu T.A., 2005, J. Appl. Sci., V5, P906, DOI [10.3923/jas.2005.906.909, DOI 10.3923/JAS.2005.906.909]
[3]  
BAGES S, 1996, Patent No. 9611399
[4]   Geographical origin classification of petroleum crudes from near-infrared spectra of bitumens [J].
Blanco, M ;
Maspoch, S ;
Villarroya, I ;
Peralta, X ;
González, JM ;
Torres, J .
APPLIED SPECTROSCOPY, 2001, 55 (07) :834-839
[5]   Multiblock PLS as an approach to compare and combine NIR and MIR spectra in calibrations of soybean flour [J].
Brás, LP ;
Bernardino, SA ;
Lopes, JA ;
Menezes, JC .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2005, 75 (01) :91-99
[6]  
BROWN JM, 2006, Patent No. 2006023800
[7]   Moment combined partial least squares (MC-PLS) as an improved quantitative calibration method: application to the analyses of petroleum and petrochemical products [J].
Chung, H ;
Cho, SW ;
Toyoda, Y ;
Nakano, K ;
Maeda, M .
ANALYST, 2006, 131 (05) :684-691
[8]   Comparison of near-infrared and mid-infrared spectroscopy for the determination of distillation property of kerosene [J].
Chung, H ;
Ku, MS ;
Lee, JS .
VIBRATIONAL SPECTROSCOPY, 1999, 20 (02) :155-163
[9]   Applications of near-infrared spectroscopy in refineries and important issues to address [J].
Chung, Hoeil .
APPLIED SPECTROSCOPY REVIEWS, 2007, 42 (03) :251-285
[10]  
Cloutis E.A., 1990, AOSTRA Journal of Research, V6, P17