Experimental and computational evaluation of a flow-through UV-LED reactor for MS2 and adenovirus inactivation

被引:21
作者
Keshavarzfathy, Majid [1 ]
Hosoi, Yamato [2 ]
Oguma, Kumiko [2 ]
Taghipour, Fariborz [1 ]
机构
[1] Univ British Columbia, Dept Chem & Biol Engn, 2360 East Mall, Vancouver, BC V6T 1Z3, Canada
[2] Univ Tokyo, Grad Sch Engn, Dept Urban Engn, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
关键词
Irradiation method; Fluence rate-velocity conformity; Adenovirus; MS2; Computational Fluid Dynamics; UV-LED reactor design; LIGHT-EMITTING-DIODES; FLUENCE RATE; WATER; DISINFECTION; RADIATION;
D O I
10.1016/j.cej.2020.127058
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The design of efficient ultraviolet light emitting diode (UV-LED) reactors is of paramount importance for delivering a high UV dose (fluence). This is particularly critical to the disinfection of UV-resistant organisms, such as adenovirus, in continuous UV systems, given the low wall plug efficiency of UV-LEDs. The UV-LED offers reactor design flexibility, allowing to conform the reactor fluence rate to its hydrodynamics to a high degree, leading to improved design efficiency. In this study, we designed and fabricated a flow-through multi-baffle UV-LED reactor containing 18 UV-LEDs for delivering high UV fluence to a flow of water. Further, we developed a computational model for simulating the reactor performance, to fine-tune the fluence rate and hydrodynamics conformity through exploring several design concepts. The model was evaluated by experimental studies using male-specific-2 (MS2) bacteriophage and adenovirus as the model UV resistance microorganisms. The radiant field was adjusted through the LED arrangement and radiation profile modification. The reactor performance was studied under six different LED arrangements, three irradiation modes, and flow rates of 0.75, 1, and 2 L min(-1). Adenovirus inactivation at 1 L min(-1) from 1.6 logs increased to 4.1 logs through radiant field modification and enhancing the design efficiency. It was observed that the flexibility offered by UV-LEDs in adjusting the radiation pattern and hydrodynamics could lead to the design of highly-efficient reactors through positively correlating the UV fluence rate profile with the velocity filed. This study presents a detailed discussion concerning irradiation methods and provides insights applicable to UV-LED reactor design.
引用
收藏
页数:10
相关论文
共 33 条
  • [1] The disinfection efficacy of a point-of-use water treatment system against bacterial, viral and protozoan waterborne pathogens
    Abbaszadegan, M
    Hasan, MN
    Gerba, CP
    Roessler, PF
    Wilson, ER
    Kuennen, R
    VanDellen, E
    [J]. WATER RESEARCH, 1997, 31 (03) : 574 - 582
  • [2] Inactivation of adenovirus types 2, 5, and 41 in drinking water by UV light, free chlorine, and mlonochlorarnine
    Baxter, Carole S.
    Hofmann, Ron
    Templeton, Michael R.
    Brown, Martha
    Andrews, Robert C.
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 2007, 133 (01) : 95 - 103
  • [3] Evaluating UV-C LED disinfection performance and investigating potential dual-wavelength synergy
    Beck, Sara E.
    Ryu, Hodon
    Boczek, Laura A.
    Cashdollar, Jennifer L.
    Jeanis, Kaitlyn M.
    Rosenblum, James S.
    Lawal, Oliver R.
    Linden, Karl G.
    [J]. WATER RESEARCH, 2017, 109 : 207 - 216
  • [4] Bolton J.R., 2017, IUVA News, V19, P10
  • [5] Bolton J.R., 2008, ULTRAVIOLET DISINFEC
  • [6] Rethinking the Concepts of Fluence (UV Dose) and Fluence Rate: The Importance of Photon-based Units - A Systemic Review
    Bolton, James R.
    Mayor-Smith, Ian
    Linden, Karl G.
    [J]. PHOTOCHEMISTRY AND PHOTOBIOLOGY, 2015, 91 (06) : 1252 - 1262
  • [7] Calculation of ultraviolet fluence rate distributions in an annular reactor: Significance of refraction and reflection
    Bolton, JR
    [J]. WATER RESEARCH, 2000, 34 (13) : 3315 - 3324
  • [8] Inactivation of adenovirus using low-dose UV/H2O2 advanced oxidation
    Bounty, Sarah
    Rodriguez, Roberto A.
    Linden, Karl G.
    [J]. WATER RESEARCH, 2012, 46 (19) : 6273 - 6278
  • [9] Collins D.A., 2017, Ultraviolet Disinfection System, Patent No. [US 2017/0290933 A1, 20170290933]
  • [10] Devia-orjuela J.S., 2018, ENV SCI POLLUT RES