共 27 条
Ionography of Submicron Foils and Nanostructures Using Ion Flow Generated in FS-Laser Cluster Plasma
被引:4
作者:
Faenov, A. Ya.
[1
,2
]
Pikuz, T. A.
[1
,2
]
Pikuz, S. A., Jr.
[1
]
Fukuda, Y.
[2
]
Kando, M.
[2
]
Kotaki, H.
[2
]
Homma, T.
[2
]
Kawase, K.
[2
]
Kameshima, T.
[2
]
Pirozhkov, A.
[2
]
Yogo, A.
[2
]
Tampo, M.
[2
]
Kartashev, V.
[1
]
Skobelev, I. Yu.
[1
]
Gasilov, S. V.
[1
]
Boldarev, A. S.
[4
]
Gasilov, V. A.
[4
]
Magunov, A.
[5
]
Kar, S.
[6
]
Borghesi, M.
[6
]
Giulietti, A.
[3
]
Cecchetti, C. A.
[3
]
Mori, M.
[2
]
Sakaki, H.
[2
]
Hayashi, Y.
[2
]
Bolton, P.
[2
]
Nakamura, T.
[2
]
Daido, H.
[2
]
Tajima, T.
[2
]
Kato, Y.
[7
]
Bulanov, S. V.
[2
,5
]
机构:
[1] Joint Inst High Temp RAS, Moscow 125412, Russia
[2] Kansai Photon Sci Inst JAEA, Kyoto 6190215, Japan
[3] ILIL Ist Proc Chim Fis CNR, I-56124 Pisa, Italy
[4] Inst Math Modeling RAS, Moscow, Russia
[5] AM Prokhorov Inst Gen Phys RAS, Moscow, Russia
[6] Queens Univ Belfast, Belfast BT7 1NN, Antrim, North Ireland
[7] Grad Sch Creat New Photon Ind, Hamamatsu, Shizuoka, Japan
基金:
英国工程与自然科学研究理事会;
俄罗斯基础研究基金会;
关键词:
Ultra-intense;
ultra-short laser interaction with clusters;
fast ion acceleration;
imaging techniques;
ultrathin foils diagnostics;
PROTON;
DRIVEN;
IRRADIATION;
TARGETS;
PULSE;
D O I:
10.1002/ctpp.200910050
中图分类号:
O35 [流体力学];
O53 [等离子体物理学];
学科分类号:
070204 ;
080103 ;
080704 ;
摘要:
A novel type of submicron ion radiography designed to image low-contrast objects, including nanofoils, membranes and biological structures, is proposed. It is based on femtosecond-laser-driven-cluster- plasma source of multicharged ions and polymer dosimeter film CR-39. The intense isotropic ion flow was produced by femtosecond Ti:Sa laser pulses with intensity similar to 4x10(17) W/cm(2) absorbed in the supersonic jet of the mixed He and CO2 gases. Two Focusing Spectrometers with Spatial Resolution (FSSR) were used to measure X-ray spectra of H-and He-like multicharged oxygen ions. The spectra testify that ions with energy more than 300 keV were radiated in different directions from the plasma source. High contrast ion radiography images were obtained for 2000 dpi metal mesh, 1 mu m polypropylene and 100 nm Zr foils as well as for the different biological objects. Images were recorded on a 1 mm thick CR-39 detector, placed in contact with back surface of the imaged samples at the distances 140 -160 mm from the ion source. The spatial resolution of the image no worse than 600 nm was provided. A difference in object thickness of 100 nm was very well resolved for both Zr and polymer foils. The ion radiography images recorded at different angles from the source, demonstrated almost uniform spatial distribution of ion with total number of 10(8) per shot. (C) 2009 WILEY-VCH Vertag GmbH & Co. KGaA, Weinheim
引用
收藏
页码:507 / 516
页数:10
相关论文