Effect of position of temperature sensors on the resulting volumetric accuracy of the machine tool

被引:15
作者
Holub, Michal [1 ]
Andrs, Ondrej [1 ]
Kovar, Jiri [1 ]
Vetiska, Jan [1 ]
机构
[1] Brno Univ Technol, Fac Mech Engn, Inst Prod Machines Syst & Robot, Brno, Czech Republic
关键词
Volumetric accuracy; Machine tool; LaserTRACER; Temperature; Compensation; ERROR COMPENSATION;
D O I
10.1016/j.measurement.2019.107074
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work focuses on the evaluation of the volumetric accuracy of a machine tool depending on temperature measurement errors to improve manufacturing quality. The measurement of the volumetric accuracy of the machine tool and its results is, as with each measurement, subjected to a respective measurement uncertainty. In particular, this article describes the effect of measuring the temperatures necessary to correctly evaluate the volumetric error on machine tools. From the methodical procedure of measuring the volumetric accuracy of machine tools, the most suitable requirements for positions of the temperature sensors are as close as possible to the axes of motion of the machine tool and their linear encoders. This article describes the effect of measurement errors caused by inappropriate positioning of temperature sensors on the resulting volumetric accuracy by means of a case study on a three-axis machining centre. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:8
相关论文
共 18 条
[1]   Machine Tool Rotary Axis Compensation Trough Volumetric Verification Using Laser Tracker [J].
Aguado, Sergio ;
Samper, David ;
Santolaria, Jorge ;
Jose Aguilar, Juan .
MANUFACTURING ENGINEERING SOCIETY INTERNATIONAL CONFERENCE, (MESIC 2013), 2013, 63 :582-590
[2]   Identification strategy of error parameter in volumetric error compensation of machine tool based on laser tracker measurements [J].
Aguado, Sergio ;
Samper, David ;
Santolaria, Jorge ;
Jose Aguilar, Juan .
INTERNATIONAL JOURNAL OF MACHINE TOOLS & MANUFACTURE, 2012, 53 (01) :160-169
[3]  
Brecher C., 2012, 9 INT C MACH TOOLS A, P6
[4]  
Holub Michal, 2014, Proceedings of the 16th International Conference on Mechatronics - Mechatronika (ME) 2014, P260, DOI 10.1109/MECHATRONIKA.2014.7018268
[5]  
Holub M., MM Science Journal, V2017, P2085, DOI [10.17973/MMSJ.201712201791, DOI 10.17973/MMSJ.201712201791]
[6]  
Holub M., 2015, MM Sci. J, DOI [10.17973/MMSJ.201510201534, DOI 10.17973/MMSJ.201510201534]
[7]  
Holub M., 2017, MM SCI J, V2017, P1769, DOI [10.17973/MMSJ.2017022016210, DOI 10.17973/MMSJ.2017_02_2016210]
[8]   Capability assessment of CNC machining centres as measuring devices [J].
Holub, Michal ;
Jankovych, Robert ;
Andrs, Ondrej ;
Kolibal, Zdenek .
MEASUREMENT, 2018, 118 :52-60
[9]   Impact of measurement procedure when error mapping and compensating a small CNC machine using a multilateration laser interferometer [J].
Linares, Jean-Marc ;
Chaves-Jacob, Julien ;
Schwenke, Heinrich ;
Longstaff, Andrew ;
Fletcher, Simon ;
Flore, Jakob ;
Uhlmann, Eckart ;
Wintering, Jens .
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2014, 38 (03) :578-588
[10]  
Marek J, 2009, RECENT ADVANCES IN MECHATRONICS: 2008-2009, P371