Evaluation of 4D-CT Lung Registration

被引:0
|
作者
Kabus, Sven [1 ]
Klinder, Tobias [1 ,2 ]
Murphy, Keelin [3 ]
van Ginneken, Bram [3 ]
Lorenz, Cristian [1 ]
Pluim, Josien P. W. [3 ]
机构
[1] Philips Res Europe, Hamburg, Germany
[2] Leiden Univ Hannover, Inst Informationsverarbeitung, Hamburg, Germany
[3] China Med Ctr, Utrecht, Netherlands
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS | 2009年 / 5761卷
关键词
IMAGE REGISTRATION; DEFORMABLE REGISTRATION;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Non-rigid registration accuracy assessment is typically performed by evaluating the target registration error at manually placed landmarks. For 4D-CT lung data, we compare two sets of landmark distributions: a smaller set primarily defined on vessel bifurcations as commonly, described in the literature and a larger set being well-distributed throughout the lung volume. For six different, registration schemes (three in-house schemes and three schemes frequently used by the community) the landmark error is evaluated and found to depend significantly oil the distribution of the landmarks. In particular, lung regions near to the pleura, show a target registration error three times larger lung near-mediastinal regions. While the inter-method variability oil the landmark positions is rather small, the methods show discriminating differences with respect to consistency and local volume Change. In conclusion, both a. well-distributed set of landmarks and a deformation vector field analysis are necessary For reliable non-rigid registration accuracy assessment.
引用
收藏
页码:747 / +
页数:2
相关论文
共 50 条
  • [1] A Fully Automated 4D-CT Registration Algorithm for Lung Studies
    Carnes, G.
    Gaede, S.
    Van Dyk, J.
    Battista, J.
    Lee, T.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [2] Registration Based Super-Resolution Reconstruction for Lung 4D-CT
    Wu, Xiuxiu
    Xiao, Shan
    Zhang, Yu
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2444 - 2447
  • [3] A Study of Interdependence between Vessel Enhancement and Registration for Lung 4D-CT
    Lunawat, Tejas
    Gupta, Suramya
    Bhavsar, Arnav
    2017 TWENTY-THIRD NATIONAL CONFERENCE ON COMMUNICATIONS (NCC), 2017,
  • [4] LungRegNet: An unsupervised deformable image registration method for 4D-CT lung
    Fu, Yabo
    Lei, Yang
    Wang, Tonghe
    Higgins, Kristin
    Bradley, Jeffrey D.
    Curran, Walter J.
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL PHYSICS, 2020, 47 (04) : 1763 - 1774
  • [5] Deformable registration of 4D-CT lung image using landmark tracking
    Wu, Junha
    Hu, Bingfeng
    Yang, Xuan
    BIOMEDICAL RESEARCH-INDIA, 2016, 27 (03): : 801 - 811
  • [6] Evaluation of the Effects of Dose on Lung Ventilation Calculated from 4D-CT using Deformable Image Registration An Application of a Ventilation Calculation Algorithm based on 4D-CT
    Latifi, Kujtim
    Dilling, Thomas J.
    Stevens, Craig W.
    Feygelman, Vladimir
    Moros, Eduardo G.
    Zhang, Geoffrey G.
    BIOIMAGING: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOIMAGING, 2014, : 5 - 11
  • [7] 4D-CT Lung Ventilation Images Vary with 4D-CT Sorting Techniques
    Yamamoto, T.
    Kabus, S.
    Lorenz, C.
    Johnston, E.
    Maxim, P.
    Loo, B.
    Keall, P.
    MEDICAL PHYSICS, 2012, 39 (06) : 3614 - 3614
  • [8] Boundary-aware registration network for 4D-CT lung image with sliding motion
    Duan, Luwen
    Cao, Yuzhu
    Wang, Ziyu
    Liu, Desen
    Fu, Tianxiao
    Yuan, Gang
    Zheng, Jian
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 86
  • [9] 4D-CT lung motion estimation with deformable registration: Quantification of motion nonlinearity and hysteresis
    Boldea, Vlad
    Sharp, Gregory C.
    Jiang, Steve B.
    Sarrut, David
    MEDICAL PHYSICS, 2008, 35 (03) : 1008 - 1018
  • [10] Study of motion in a 4D-CT using deformable registration
    Boldea, V
    Sarrut, D
    Sharp, G
    Jiang, S
    Choi, N
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S499 - S500