Solochrome cyanine: A histological stain for cobalt-chromium wear particles in metal-on-metal periprosthetic tissuesAntonio Merolli, Nicholas Ziats, Floyd Karp

被引:0
作者
Papadimitriou-Olivgeri, I. [1 ]
Brown, J. M. [1 ]
Kilpatrick, A. F. R. [2 ]
Gill, H. S. [3 ]
Athanasou, N. A. [1 ]
机构
[1] Univ Oxford, NDORMS, Dept Histopathol, Nuffield Orthopaed Ctr, Oxford OX3 7HE, England
[2] Chem Res Lab, Mansfield Rd, Oxford OX1 3TA, England
[3] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
关键词
TOTAL HIP-ARTHROPLASTY; HYPERSENSITIVITY; NANOPARTICLES; REPLACEMENTS; CORROSION; PRODUCTS; TISSUE; DYE;
D O I
10.1007/s10856-019-6304-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Metal-on-metal (MoM) hip arthroplasties produce abundant implant-derived wear debris composed mainly of cobalt (Co) and chromium (Cr). Cobalt-chromium (Co-Cr) wear particles are difficult to identify histologically and need to be distinguished from other wear particle types and endogenous components (e.g., haemosiderin, fibrin) which may be present in MoM periprosthetic tissues. In this study we sought to determine whether histological stains that have an affinity for metals are useful in identifying Co-Cr wear debris in MoM periprosthetic tissues. Histological sections of periprosthetic tissue from 30 failed MoM hip arthroplasties were stained with haematoxylin-eosin (HE), Solochrome Cyanine (SC), Solochrome Azurine (SA) and Perls' Prussian Blue (PB). Sections of periprosthetic tissue from 10 cases of non-MoM arthroplasties using other implant biomaterials, including titanium, ceramic, polymethylmethacrylate (PMMA) and ultra-high molecular weight polyethylene (UHMWP) were similarly analysed. Sections of 10 cases of haemosiderin-containing knee tenosynovial giant cell tumour (TSGCT) were also stained with HE, SC, SA and PB. In MoM periprosthetic tissues, SC stained metal debris in phagocytic macrophages and in the superficial necrotic zone which exhibited little or no trichrome staining for fibrin. In non-MoM periprosthetic tissues, UHMWP, PMMA, ceramic and titanium particles were not stained by SC. Prussian Blue, but not SC or SA, stained haemosiderin deposits in MoM periprosthetic tissues and TSGT. Our findings show that SC staining (most likely Cr-associated) is useful in distinguishing Co-Cr wear particles from other metal/non-metal wear particles types in histological preparations of periprosthetic tissue and that SC reliably distinguishes haemosiderin from Co-Cr wear debris.
引用
收藏
页数:8
相关论文
共 37 条
[1]   Metal in Total Hip Arthroplasty: Wear Particles, Biology, and Diagnosis [J].
Amanatullah, Derek F. ;
Sucher, Mark G. ;
Bonadurer, George F., III ;
Pereira, Gavin C. ;
Taunton, Michael J. .
ORTHOPEDICS, 2016, 39 (06) :371-379
[2]  
[Anonymous], 1994, MANUAL HISTOLOGICAL
[3]   The pathobiology and pathology of aseptic implant failure [J].
Athanasou, N. A. .
BONE & JOINT RESEARCH, 2016, 5 (05) :162-168
[4]   Biological response to prosthetic debris [J].
Bitar, Diana ;
Parvizi, Javad .
WORLD JOURNAL OF ORTHOPEDICS, 2015, 6 (02) :172-189
[5]   Histological Features of Pseudotumor-like Tissues From Metal-on-Metal Hips [J].
Campbell, Pat ;
Ebramzadeh, Edward ;
Nelson, Scott ;
Takamura, Karren ;
De Smet, Koen ;
Amstutz, Harlan C. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (09) :2321-2327
[6]   New Insights into Wear and Biological Effects of Metal-on-Metal Bearings [J].
Catelas, Isabelle ;
Wimmer, Markus A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A :76-83
[7]  
De Saint A, WHO CLASSIFICATION T, P102
[8]  
Doorn PF, 1998, J BIOMED MATER RES, V42, P103, DOI 10.1002/(SICI)1097-4636(199810)42:1<103::AID-JBM13>3.3.CO
[9]  
2-D
[10]   Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management [J].
Drummond, James ;
Phong Tran ;
Fary, Camdon .
JOURNAL OF FUNCTIONAL BIOMATERIALS, 2015, 6 (03) :486-499