Seating accuracy of implant immediate provisional prostheses fabricated by digital workflow prior to implant placement by fully guided static computer-assisted implant surgery: An in vitro study

被引:5
|
作者
Abduo, Jaafar [1 ]
Lau, Douglas [2 ]
机构
[1] Univ Melbourne, Melbourne Dent Sch, Restorat Sect, Melbourne, Vic, Australia
[2] Univ Melbourne, Melbourne Dent Sch, Melbourne, Vic, Australia
关键词
bridge; crown; milling; proximal contact; surgical guide; AESTHETIC OUTCOMES; TEMPLATES;
D O I
10.1111/clr.13731
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives Evaluation of seating accuracy of implant immediate provisional prostheses fabricated prior to fully guided static computer-assisted implant surgery (sCAIS). Materials and Methods Two maxillary training models were used to plan for single anterior (S-Ant) and single posterior (S-Post) implant prostheses, and a bridge (B) spanning from an anterior implant (B-Ant) to a posterior implant (B-Post). A commercial software was used to plan the implant location, design the surgical guides and design the provisional prostheses. The master models with the provisional prostheses were scanned to generate virtual master models. For each maxillary model, a total of 10 guides and 10 surgical models were produced. Following implant placements in each surgical model, the provisional prostheses were attached to the implants and were scanned to produce virtual surgical models. The virtual master and surgical models were superimposed to measure the vertical error, the proximal contact error and the proximal contact quality. Results The vertical error was greatest for the S-Post (0.41 mm), followed by B-Post (0.29 mm), B-Ant (0.26 mm) and S-Ant (0.21 mm). There was no significant difference in vertical errors among the prostheses. For the proximal contact, the S-Ant had significantly greater error (0.45 mm - 0.46 mm) than S-Post (0.15 mm) and B (0.09 mm - 0.15 mm). A similar pattern was observed for proximal contact quality. Conclusions All prostheses were associated with errors vertically and at the proximal contacts. Therefore, the clinicians who plan to use this workflow should be prepared to adjust the prosthesis after implant insertion.
引用
收藏
页码:608 / 618
页数:11
相关论文
共 50 条
  • [1] Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study
    Otaghsara, Seyedeh Sahar Taheri
    Joda, Tim
    Thieringer, Florian Markus
    JOURNAL OF DENTISTRY, 2023, 132
  • [2] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Anna Takács
    Gyula Marada
    Kinga Turzó
    Ákos Nagy
    Orsolya Németh
    Eitan Mijiritsky
    Márton Kivovics
    Attila Mühl
    BMC Oral Health, 23
  • [3] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Takacs, Anna
    Marada, Gyula
    Turzo, Kinga
    Nagy, Akos
    Nemeth, Orsolya
    Mijiritsky, Eitan
    Kivovics, Marton
    Muhl, Attila
    BMC ORAL HEALTH, 2023, 23 (01)
  • [4] Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study
    Li, Ping
    Zhao, Chunhui
    Chen, Jiahao
    Xu, Shulan
    Yang, Shuo
    Li, An
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1279 - 1288
  • [5] Fully Digital Workflow for Planning Static Guided Implant Surgery: A Prospective Accuracy Study
    Lin, Chia-Cheng
    Wu, Ching-Zong
    Huang, Mao-Suan
    Huang, Chiung-Fang
    Cheng, Hsin-Chung
    Wang, Dayen Peter
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (04)
  • [6] Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow
    Pascual, D.
    Vaysse, J.
    REVUE DE STOMATOLOGIE DE CHIRURGIE MAXILLO-FACIALE ET DE CHIRURGIE ORALE, 2016, 117 (01) : 28 - 35
  • [7] In vitro and in vivo accuracy of autonomous robotic vs. fully guided static computer-assisted implant surgery
    He, Jin
    Zhang, Qinmeng
    Wang, Xueting
    Fu, Mengdie
    Zhang, Hui
    Song, Luyao
    Pu, Rui
    Jiang, Zhiwei
    Yang, Guoli
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 385 - 401
  • [8] Accuracy of computer-assisted, template-guided implant placement compared with conventional implant placement by hand-An in vitro study
    Schneider, David
    Sax, Caroline
    Sancho-Puchades, Manuel
    Hammerle, Christoph H. F.
    Jung, Ronald Ernst
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (09) : 1052 - 1060
  • [9] The accuracy of implant placement using a combination of static and dynamic computer-assisted implant surgery in fully edentulous arches: A prospective controlled clinical study
    Lorwicheanrung, Jarungvit
    Mahardawi, Basel
    Arunjaroensuk, Sirida
    Kaboosaya, Boosana
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (08) : 841 - 853
  • [10] Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study
    Ruiz-Romero, Victor
    Jorba-Garcia, Adria
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    JOURNAL OF DENTISTRY, 2024, 149