New developments in CdTe and CdZnTe detectors for x and gamma-ray applications

被引:68
|
作者
Veger, L
Bonnefoy, JP
Glasser, F
OuvrierBuffet, P
机构
[1] LETI, DSYS/CEA Grenoble, 38054 - Grenoble Cedex, 17, rue des Martyrs
关键词
CdTe detectors; CdZnTe detectors; pulse height correction method; x- and gamma-ray applications; x-ray imager;
D O I
10.1007/s11664-997-0225-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There has been considerable resent progress in II-VI semiconductor material and in methods for improving performance of the associated radiation detectors. New high resistivity CdZnTe material, new contact technologies, new detector structures, new electronic correction methods have opened the field of nuclear and x-ray imaging for industrial and medical applications. The purpose of this paper is to review new developments in several of these fields. In addition, we will present some recent results at LETI concerning first the CdTe 2-D imaging system (20 x 30 mm(2) with 400 x 600 pixels) for dental radiology and second the CdZnTe fast pulse correction method applied to a 5 x 5 x 5 mm(3) CdZnTe detector (energy resolution = 5% for detection efficiency of 85% at 122 keV) for medical imaging.
引用
收藏
页码:738 / 744
页数:7
相关论文
共 50 条
  • [41] Recent developments in semiconductor gamma-ray detectors
    Luke, PN
    Amman, M
    Tindall, C
    Lee, JS
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 264 (01) : 145 - 153
  • [42] Multielement CdTe stack detectors for gamma-ray spectroscopy
    Redus, R
    Huber, A
    Pantazis, J
    Pantazis, T
    Takahashi, T
    Woolf, S
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3361 - 3365
  • [43] CRYSTAL-GROWTH OF CDTE FOR GAMMA-RAY DETECTORS
    WALD, FV
    ENTINE, G
    NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (01): : 13 - 23
  • [44] Multielement CdTe stack detectors for gamma-ray spectroscopy
    Redus, R
    Huber, A
    Pantazis, J
    Pantazis, T
    Takahashi, T
    Woolf, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2386 - 2394
  • [45] Multielement CdTe stack detectors for gamma-ray spectroscopy
    Redus, R.
    Huber, A.
    Pantazis, J.
    Pantazis, T.
    Takahashi, T.
    Woolf, S.
    IEEE Transactions on Nuclear Science, 2004, 51 (5 I) : 2386 - 2394
  • [46] CONTACTS ON CHEMICALLY ETCHED CDTE GAMMA-RAY DETECTORS
    MUSA, A
    PONPON, JP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 216 (1-2): : 259 - 263
  • [47] Study of Surface Passivation and Contact Deposition Techniques in CdZnTe X-Ray and Gamma-Ray Detectors
    Jones, Dominique E.
    Egarievwe, Stephen U.
    Hossain, Anwar
    Okwechime, Ifechukwude O.
    Drabo, Mebougna L.
    Hall, JaQueeta
    Adams, Aaron L.
    Babalola, Stephen O.
    Camarda, Giuseppe S.
    Bolotnikov, Aleksey E.
    Chan, Wing
    James, Ralph B.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4124 - 4127
  • [48] Characterization of CdZnTe and CdTe:Cl materials and their relationship to X- and gamma-ray detector performance
    Verger, L
    Baffert, N
    Rosaz, M
    Rustique, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 121 - 126
  • [49] CHARACTERIZATION OF HIGH RESISTIVITY CDTE FOR GAMMA-RAY DETECTORS
    CANALI, C
    MARTINI, M
    OTTAVIANI, G
    ALBERIGI.A
    ZANIO, KR
    NUCLEAR INSTRUMENTS & METHODS, 1971, 96 (04): : 561 - +
  • [50] Medical applications of CdTe and CdZnTe detectors
    Scheiber, C
    Giakos, GC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 12 - 25