New developments in CdTe and CdZnTe detectors for x and gamma-ray applications

被引:68
|
作者
Veger, L
Bonnefoy, JP
Glasser, F
OuvrierBuffet, P
机构
[1] LETI, DSYS/CEA Grenoble, 38054 - Grenoble Cedex, 17, rue des Martyrs
关键词
CdTe detectors; CdZnTe detectors; pulse height correction method; x- and gamma-ray applications; x-ray imager;
D O I
10.1007/s11664-997-0225-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There has been considerable resent progress in II-VI semiconductor material and in methods for improving performance of the associated radiation detectors. New high resistivity CdZnTe material, new contact technologies, new detector structures, new electronic correction methods have opened the field of nuclear and x-ray imaging for industrial and medical applications. The purpose of this paper is to review new developments in several of these fields. In addition, we will present some recent results at LETI concerning first the CdTe 2-D imaging system (20 x 30 mm(2) with 400 x 600 pixels) for dental radiology and second the CdZnTe fast pulse correction method applied to a 5 x 5 x 5 mm(3) CdZnTe detector (energy resolution = 5% for detection efficiency of 85% at 122 keV) for medical imaging.
引用
收藏
页码:738 / 744
页数:7
相关论文
共 50 条
  • [31] CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 428 (01): : 158 - 170
  • [32] CdTe and CdZnTe gamma ray detectors for medical and industrial imaging systems
    Soreq NRC, 81800 Yavne, Israel
    Nucl Instrum Methods Phys Res Sect A, 1 (158-170):
  • [33] Assessment of a new ZnO:Al contact to CdZnTe for X- and gamma-ray detector applications
    Roy, U. N.
    Camarda, G. S.
    Cui, Y.
    Gul, R.
    Hossain, A.
    Yang, G.
    Mundle, R. M.
    Pradhan, A. K.
    James, R. B.
    AIP ADVANCES, 2017, 7 (09):
  • [34] X ray and gamma ray spectroscopy with segmented CdZnTe detectors
    Shor, A
    Eisen, Y
    Mardor, I
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS, 1999, 3769 : 59 - 70
  • [35] The energy dependence of the sensitivity for planar CdZnTe gamma-ray detectors
    Zakharchenko, Alexandr A.
    Skrypnyk, Anna I.
    Khazhmuradov, Manap A.
    Rybka, Alexandr V.
    Kutny, Vladimir E.
    Fochuk, Petro M.
    Sklyarchuk, Valery M.
    Bolotnikov, A. E.
    James, R. B.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XV, 2013, 8852
  • [36] Transport properties and spectrometric performances of CdZnTe gamma-ray detectors
    Zakharchenko, Alexandr A.
    Rybka, Alexandr V.
    Kutny, Vladimir E.
    Skrypnyk, Anna I.
    Khazhmuradov, Manap A.
    Fochuk, Petro M.
    Bolotnikov, Aleksey E.
    James, Ralph B.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIV, 2012, 8507
  • [37] Recent developments in semiconductor gamma-ray detectors
    P. N. Luke
    M. Amman
    C. Tindall
    J. S. Lee
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 145 - 153
  • [38] Simulation and experimental results on monolithic CdZnTe gamma-ray detectors
    d'Aillon, EG
    Gentet, MC
    Montémont, G
    Rustique, J
    Verger, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4451 - 4455
  • [39] Performance of CdZnTe coplanar-grid gamma-ray detectors
    Luke, PN
    Eissler, EE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1481 - 1486
  • [40] Simulation and experimental results on monolithic CdZnTe gamma-ray detectors
    d'Aillon, EG
    Gentet, MC
    Montémont, G
    Rustique, J
    Verger, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 3096 - 3102