New developments in CdTe and CdZnTe detectors for x and gamma-ray applications

被引:68
|
作者
Veger, L
Bonnefoy, JP
Glasser, F
OuvrierBuffet, P
机构
[1] LETI, DSYS/CEA Grenoble, 38054 - Grenoble Cedex, 17, rue des Martyrs
关键词
CdTe detectors; CdZnTe detectors; pulse height correction method; x- and gamma-ray applications; x-ray imager;
D O I
10.1007/s11664-997-0225-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
There has been considerable resent progress in II-VI semiconductor material and in methods for improving performance of the associated radiation detectors. New high resistivity CdZnTe material, new contact technologies, new detector structures, new electronic correction methods have opened the field of nuclear and x-ray imaging for industrial and medical applications. The purpose of this paper is to review new developments in several of these fields. In addition, we will present some recent results at LETI concerning first the CdTe 2-D imaging system (20 x 30 mm(2) with 400 x 600 pixels) for dental radiology and second the CdZnTe fast pulse correction method applied to a 5 x 5 x 5 mm(3) CdZnTe detector (energy resolution = 5% for detection efficiency of 85% at 122 keV) for medical imaging.
引用
收藏
页码:738 / 744
页数:7
相关论文
共 50 条
  • [1] New trends in CdTe and CdZnTe detectors for X- and gamma-ray applications
    Limousin, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3): : 24 - 37
  • [2] New developments in CdTe and CdZnTe detectors for X and γ-ray applications
    L. Verger
    J. P. Bonnefoy
    F. Glasser
    P. Ouvrier-Buffet
    Journal of Electronic Materials, 1997, 26 : 738 - 744
  • [3] Characterization of CdTe and CdZnTe detectors for gamma-ray imaging applications
    Verger, L
    Boitel, M
    Gentet, MC
    Hamelin, R
    Mestais, C
    Mongellaz, F
    Rustique, J
    Sanchez, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 297 - 309
  • [4] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 1191 - 1198
  • [5] CdTe and CdZnTe X-ray and gamma-ray detectors for imaging systems
    Eisen, Y
    Shor, A
    Mardor, I
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3311 - 3319
  • [6] New trends in CdTe and CdZnTe detectors for X- and gamma-ray applications (vol 504, pg 24, 2003)
    Limousin, O
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (03): : 651 - 651
  • [7] CdTe and CdZnTe crystals for room temperature gamma-ray detectors
    Franc, J
    Höschl, P
    Belas, E
    Grill, R
    Hlídek, P
    Moravec, P
    Bok, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 434 (01): : 146 - 151
  • [8] Dynamics of native oxide growth on CdTe and CdZnTe X-ray and gamma-ray detectors
    Zazvorka, Jakub
    Franc, Jan
    Beran, Lukas
    Moravec, Pavel
    Pekarek, Jakub
    Veis, Martin
    SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS, 2016, 17 (01) : 792 - 798
  • [9] New developments in clinical applications of CdTe and CdZnTe detectors
    Scheiber, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2): : 385 - 391
  • [10] A System for the Characterization and Testing of CdZnTe/CdTe Pixel Detectors for X-ray and Gamma-ray Imaging
    Arodzero, Anatoli
    Barber, William C.
    Damron, Matthew Q.
    Hartsough, Neal E.
    Iwanczyk, Jan S.
    Malakhov, Nail
    Nygard, Einar
    Moraes, Danielle
    Weilhammer, Peter
    Jarron, Pierre
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3638 - 3642