Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats

被引:27
|
作者
Woderer, Stefanie
Henninger, Nadja
Garthe, Claus-Dieter
Kloetzer, Hans Martin
Hajnsek, Martin
Kamecke, Ulrike
Gretz, Norbert
Kraenzlin, Bettina
Pill, Johannes
机构
[1] Roche Diagnost GmbH, D-68305 Mannheim, Germany
[2] Heidelberg Univ, Univ Hosp Mannheim, Med Res Ctr, D-68167 Mannheim, Germany
[3] Roche Diagnost GmbH, A-8020 Graz, Austria
[4] Metecon GmbH, D-68165 Mannheim, Germany
关键词
glucose biosensor; continuous glucose monitoring; glucose oxidase; glucose in interstitial fluid; blood glucose; rat;
D O I
10.1016/j.aca.2006.08.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose monitoring is of importance for success of complex therapeutic interventions in diabetic patients. Its impact on treatment and glycemic control is demonstrated in large clinical trials. Up to eight blood glucose measurements per day are recommended. Notwithstanding, a substantial number of diabetic patients cannot or will not monitor their blood glucose appropriately. Considerable progress in control of disturbed metabolism in diabetic patients can be expected by continuous glucose monitoring. The aim of the study was to evaluate the performance of a new amperometric glucose oxidase-based glucose sensor in vitro and in vivo after subcutaneous implantation into rats. For in vitro testing current output of sensors was measured by exposure to increasing and decreasing glucose concentrations up to 472 mg dL(-1) over a time period of 7 days. After subcutaneous implantation of sensors into interscapular region of male rats glucose in interstitial fluid was evaluated and compared to glucose in arterial blood up to 7 days. Hyper- and hypoglycaemia were induced by intravenous application of glucose and insulin, respectively. Current of each implanted sensor was converted into glucose concentration using the first blood glucose measurement only. A change of current with glucose of 0.35 nA mg(-1) dL(-1) indicates high sensitivity of the sensor in vitro. The response time (90% of steady state) was calculated by approximately 60 s. Test strips for blood glucose measurement as reference for sensor readings was found as an appropriate and rapidly available method in rats by comparison with established hexokinase method in an automated lab analyzer with limits of agreement of +32.8 and -25.7 mg dL(-1) in Bland-Altman analysis. In normo- and hypoglycaemic range sensor readings in interstitial fluid correlated well with blood glucose measurements whereas hyperglycaemia was not reflected by the sensor completely when blood glucose was changing rapidly. The data given characterize a sensor with high sensitivity, long term stability and short response time. A single calibration of the sensor is required only in measurement periods up to 7 days. The findings demonstrate that the sensor is a highly promising candidate for assessment in humans. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [31] Highly sensitive glucose biosensor using new glucose oxidase based biocatalyst
    Christwardana, Marcelinus
    Ji, Jungyeon
    Chung, Yongjin
    Kwon, Yongchai
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2017, 34 (11) : 2916 - 2921
  • [32] Highly sensitive glucose biosensor using new glucose oxidase based biocatalyst
    Marcelinus Christwardana
    Jungyeon Ji
    Yongjin Chung
    Yongchai Kwon
    Korean Journal of Chemical Engineering, 2017, 34 : 2916 - 2921
  • [33] Prediction of blood glucose using interstitial fluid extracted by ultrasound and vacuum
    Li Dachao
    Yu Haixia
    Huang Xian
    Huang Fuxiang
    Hu Xiaotang
    Xu Kexin
    OPTICAL DIAGNOSTICS AND SENSING VII, 2007, 6445
  • [34] Development of a fluorescent method for simultaneous measurement of glucose concentrations in interstitial fluid and blood
    Shi, Ting
    Li, Dachao
    Li, Guoqing
    Chen, Limin
    Lin, Yuan
    Xu, Kexin
    Lu, Luo
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (12)
  • [35] Evaluation of MOSFET type glucose sensor using platinum electrode with glucose oxidase
    Ooe, K
    Hamamoto, Y
    Hirano, Y
    BIOMEDICAL APPLICATIONS OF MICRO- AND NANOENGINEERING II, 2005, 5651 : 310 - 320
  • [36] Blood Glucose Alterations and Continuous Glucose Monitoring in Centrifuge-Simulated Spaceflight
    Ong, Karen M.
    Rossitto, Josie J.
    Ray, Kristi
    Dufurrena, Quinn A.
    Blue, Rebecca S.
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2022, 93 (09) : 688 - 695
  • [37] Continuous Blood Glucose Monitoring Reveals Enormous Circadian Variations in Pregnant Diabetic Rats
    Golic, Michaels
    Kraker, Kristin
    Fischer, Caroline
    Alenina, Natalia
    Haase, Nadine
    Herse, Florian
    Schuette, Till
    Henrich, Wolfgang
    Mueller, Dominik N.
    Busjahn, Andreas
    Bader, Michael
    Dechend, Ralf
    FRONTIERS IN ENDOCRINOLOGY, 2018, 9
  • [38] Glucose oxidase immobilized macro porous silicon based conductive glucose sensor
    Tanusree Sarkar
    Nandini Mukherjee
    Jayoti Das
    Applied Physics A, 2022, 128
  • [39] Application of Dissolving Microneedles to Glucose Monitoring through Dermal Interstitial Fluid
    Ito, Yukako
    Taniguchi, Mayu
    Hayashi, Asuka
    Anai, Miku
    Morita, Shinya
    Ko, Emi
    Yoshimoto, Naoko
    Yoshii, Yasuhiro
    Kobuchi, Shinji
    Sakaeda, Toshiyuki
    Takade, Kanji
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2014, 37 (11) : 1776 - 1781
  • [40] A systematic review: Cost-effectiveness of continuous glucose monitoring compared to self-monitoring of blood glucose in type 1 diabetes
    Jiao, Yuxin
    Lin, Rose
    Hua, Xinyang
    Churilov, Leonid
    Gaca, Michele J.
    James, Steven
    Clarke, Philip M.
    O'Neal, David
    Ekinci, Elif, I
    ENDOCRINOLOGY DIABETES & METABOLISM, 2022, 5 (06)