Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats

被引:27
|
作者
Woderer, Stefanie
Henninger, Nadja
Garthe, Claus-Dieter
Kloetzer, Hans Martin
Hajnsek, Martin
Kamecke, Ulrike
Gretz, Norbert
Kraenzlin, Bettina
Pill, Johannes
机构
[1] Roche Diagnost GmbH, D-68305 Mannheim, Germany
[2] Heidelberg Univ, Univ Hosp Mannheim, Med Res Ctr, D-68167 Mannheim, Germany
[3] Roche Diagnost GmbH, A-8020 Graz, Austria
[4] Metecon GmbH, D-68165 Mannheim, Germany
关键词
glucose biosensor; continuous glucose monitoring; glucose oxidase; glucose in interstitial fluid; blood glucose; rat;
D O I
10.1016/j.aca.2006.08.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Glucose monitoring is of importance for success of complex therapeutic interventions in diabetic patients. Its impact on treatment and glycemic control is demonstrated in large clinical trials. Up to eight blood glucose measurements per day are recommended. Notwithstanding, a substantial number of diabetic patients cannot or will not monitor their blood glucose appropriately. Considerable progress in control of disturbed metabolism in diabetic patients can be expected by continuous glucose monitoring. The aim of the study was to evaluate the performance of a new amperometric glucose oxidase-based glucose sensor in vitro and in vivo after subcutaneous implantation into rats. For in vitro testing current output of sensors was measured by exposure to increasing and decreasing glucose concentrations up to 472 mg dL(-1) over a time period of 7 days. After subcutaneous implantation of sensors into interscapular region of male rats glucose in interstitial fluid was evaluated and compared to glucose in arterial blood up to 7 days. Hyper- and hypoglycaemia were induced by intravenous application of glucose and insulin, respectively. Current of each implanted sensor was converted into glucose concentration using the first blood glucose measurement only. A change of current with glucose of 0.35 nA mg(-1) dL(-1) indicates high sensitivity of the sensor in vitro. The response time (90% of steady state) was calculated by approximately 60 s. Test strips for blood glucose measurement as reference for sensor readings was found as an appropriate and rapidly available method in rats by comparison with established hexokinase method in an automated lab analyzer with limits of agreement of +32.8 and -25.7 mg dL(-1) in Bland-Altman analysis. In normo- and hypoglycaemic range sensor readings in interstitial fluid correlated well with blood glucose measurements whereas hyperglycaemia was not reflected by the sensor completely when blood glucose was changing rapidly. The data given characterize a sensor with high sensitivity, long term stability and short response time. A single calibration of the sensor is required only in measurement periods up to 7 days. The findings demonstrate that the sensor is a highly promising candidate for assessment in humans. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [21] Long-Term Continuous Glucose Monitoring Using a Fluorescence-Based Biocompatible Hydrogel Glucose Sensor
    Sawayama, Jun
    Takeuchi, Shoji
    ADVANCED HEALTHCARE MATERIALS, 2021, 10 (03)
  • [22] Acid phosphatase/glucose oxidase-based biosensors for the determination of pesticides
    Mazzei, F
    Botre, F
    Botre, C
    ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) : 67 - 75
  • [23] Optical Sensor Based Continuous Blood Glucose Estimation Using Lightweight Distributed Architecture
    Ketan Lad
    Maulin Joshi
    Amit Joshi
    SN Computer Science, 5 (8)
  • [24] Glucose oxidase-based enzyme immobilised on tapered optical fibre for reliability improvement in selective glucose sensing
    Aziz, M. S.
    Shamsudin, M. S.
    Fahri, M. A. S. A.
    Syuhada, A.
    Ibrahim, R. K. Raja
    Bakhtiar, H.
    Harun, S. W.
    OPTIK, 2022, 259
  • [25] Skin Patchable Sensor Surveillance for Continuous Glucose Monitoring
    Manasa, G.
    Mascarenhas, Ronald J.
    Shetti, Nagaraj P.
    Malode, Shweta J.
    Mishra, Amit
    Basu, Soumen
    Aminabhavi, Tejraj M.
    ACS APPLIED BIO MATERIALS, 2022, 5 (03) : 945 - 970
  • [26] Continuous Interstitial Glucose Measurement for Flap Venous Occlusion Monitoring in a Diabetic Model
    Zhang, Chang
    Wang, Qianwen
    Wu, Lehao
    Wang, Jue
    Zhao, Sichun
    Wang, Jiaqi
    JOURNAL OF CRANIOFACIAL SURGERY, 2022, 33 (08) : 2698 - 2703
  • [27] Continuous Monitoring of Interstitial Fluid Glucose Responses to Endurance Exercise with Different Levels of Carbohydrate Intake
    Hiromatsu, Chiyori
    Kasahara, Naoto
    Lin, Chao-An
    Wang, Feifei
    Goto, Kazushige
    NUTRIENTS, 2023, 15 (22)
  • [28] In vivo continuous glucose monitoring using a chip based near infrared sensor
    Ben Mohammadi, L.
    Sigloch, S.
    Frese, I.
    Welzel, K.
    Goeddel, M.
    Klotzbuecher, T.
    BIOPHOTONICS: PHOTONIC SOLUTIONS FOR BETTER HEALTH CARE IV, 2014, 9129
  • [29] Glucose sensor based on organic thin film transistor using glucose oxidase and conducting polymer
    Liu, J.
    Agarwal, M.
    Varahramyan, K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) : 195 - 199
  • [30] Recent advances in glucose oxidase-based nanocarriers for tumor targeting therapy
    Li, Su
    Wang, Qinghua
    Jia, Zhen
    Da, Mengting
    Zhao, Jiuda
    Yang, Rui
    Chen, Daozhen
    HELIYON, 2023, 9 (10)