Operation of photon diagnostic imagers for beam commissioning at the European XFEL

被引:11
作者
Koch, Andreas [1 ]
Risch, Johannes [1 ]
Freund, Wolfgang [1 ]
Maltezopoulos, Theophilos [1 ]
Planas, Marc [1 ]
Gruenert, Jan [1 ]
机构
[1] European XFEL, D-22869 Schenefeld, Germany
关键词
X-ray imaging; beam diagnostics; X-ray free-electron lasers; beam transport systems; scintillators;
D O I
10.1107/S1600577519008737
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray photon beam diagnostic imagers are located at 24 positions in the European XFEL beam transport system to characterize the X-ray beam properties, and to give feedback for tuning and optimization of the electron acceleration and orbit, the undulators, and the X-ray optics. One year of commissioning allowed experience to be gained with these imagers, which will be reported here. The sensitive Spontaneous Radiation imager is useful for various investigations in spontaneous radiation mode: for undulator adjustments and for low-signal imaging applications. Thehigh-resolution Free-Electron Laser imager, 10 mu m spatial resolution, is extensively used for the monitoring of beam position, spot size and shape, gain curve measurements, and also for beam-intensity monitoring. The wide field-of-view pop-in monitors (up to 200mm) are regularly used for alignment and tuning of the various X-ray optical components like mirrors, slits and monochromators, and also for on-line beam control of a stable beam position at the instruments. The Exit Slit imager after the soft X-ray monochromator provides spectral information of the beam together with multi-channel plate based single-pulse gating. For particular use cases, these special features of the imagers are described. Some radiation-induced degradation of scintillators took place in this initial commissioning phase, providing useful information for better understanding of damage thresholds. Visible-light radiation in the beam pipe generated by upstream bending magnets caused spurious reflections in the optical system of some of the imagers which can be suppressed by aluminium-coated scintillating screens.
引用
收藏
页码:1489 / 1495
页数:7
相关论文
共 9 条
  • [1] Soft x-ray free-electron laser induced damage to inorganic scintillators
    Burian, Tomas
    Hajkova, Vera
    Chalupsky, Jaromr
    Vysin, Ludek
    Bohacek, Pavel
    Precek, Martin
    Wild, Jan
    Ozkan, Cigdem
    Coppola, Nicola
    Farahani, Shafagh Dastjani
    Schulz, Joachim
    Sinn, Harald
    Tschentscher, Thomas
    Gaudin, Jerome
    Bajt, Sasa
    Tiedtke, Kai
    Toleikis, Sven
    Chapman, Henry N.
    Loch, Rolf A.
    Jurek, Marek
    Sobierajski, Ryszard
    Krzywinski, Jacek
    Moeller, Stefan
    Harmand, Marion
    Galasso, Germano
    Nagasono, Mitsuru
    Saskl, Karel
    Sovak, Pavol
    Juha, Libor
    [J]. OPTICAL MATERIALS EXPRESS, 2015, 5 (02): : 254 - 264
  • [2] First measurements with the K-monochromator at the European XFEL
    Freund, Wolfgang
    Froehlich, Lars
    Karabekyan, Suren
    Koch, Andreas
    Liu, Jia
    Noelle, Dirk
    Wilgen, Josef
    Gruenert, Jan
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1037 - 1044
  • [3] X-ray photon diagnostics at the European XFEL
    Gruenert, Jan
    Carbonell, Marc Planas
    Dietrich, Florian
    Falk, Torben
    Freund, Wolfgang
    Koch, Andreas
    Kujala, Naresh
    Laksman, Joakim
    Liu, Jia
    Maltezopoulos, Theophilos
    Tiedtke, Kai
    Jastrow, Ulf Fini
    Sorokin, Andrey
    Syresin, Evgeny
    Grebentsov, Alexander
    Brovko, Oleg
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1422 - 1431
  • [4] Design and initial characterisation of x-ray beam diagnostic imagers for the European XFEL
    Koch, Andreas
    Freund, Wolfgang
    Gruenert, Jan
    Planas, Marc
    Roth, Thomas
    Samoylova, Liubov
    Lyamayev, Viktor
    [J]. ADVANCES IN X-RAY FREE-ELECTRON LASERS INSTRUMENTATION III, 2015, 9512
  • [5] SASE3-Soft X-Ray Beamline at European XFEL
    La Civita, Daniele
    Gerasimova, Natalia
    Sinn, Harald
    Vannoni, Maurizio
    [J]. X-RAY FREE-ELECTRON LASERS: BEAM DIAGNOSTICS, BEAMLINE INSTRUMENTATION, AND APPLICATIONS II, 2014, 9210
  • [6] Operation of X-ray gas monitors at the European XFEL
    Maltezopoulos, Theophilos
    Dietrich, Florian
    Freund, Wolfgang
    Jastrow, Ulf Fini
    Koch, Andreas
    Laksman, Joakim
    Liu, Jia
    Planas, Marc
    Sorokin, Andrey A.
    Tiedtke, Kai
    Gruenert, Jan
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1045 - 1051
  • [7] An X-ray gas monitor for free-electron lasers
    Sorokin, Andrey A.
    Bican, Yilmaz
    Bonfigt, Susanne
    Brachmanski, Maciej
    Braune, Markus
    Jastrow, Ulf Fini
    Gottwald, Alexander
    Kaser, Hendrik
    Richter, Mathias
    Tiedtke, Kai
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1092 - 1100
  • [8] Gas detectors for x-ray lasers
    Tiedtke, K.
    Feldhaus, J.
    Hahn, U.
    Jastrow, U.
    Nunez, T.
    Tschentscher, T.
    Bobashev, S. V.
    Sorokin, A. A.
    Hastings, J. B.
    Moeller, S.
    Cibik, L.
    Gottwald, A.
    Hoehl, A.
    Kroth, U.
    Krumrey, M.
    Schoeppe, H.
    Ulm, G.
    Richter, M.
    [J]. JOURNAL OF APPLIED PHYSICS, 2008, 103 (09)
  • [9] Photon Beam Transport and Scientific Instruments at the European XFEL
    Tschentscher, Thomas
    Bressler, Christian
    Gruenert, Jan
    Madsen, Anders
    Mancuso, Adrian P.
    Meyer, Michael
    Scherz, Andreas
    Sinn, Harald
    Zastrau, Ulf
    [J]. APPLIED SCIENCES-BASEL, 2017, 7 (06):