Fast blood flow monitoring in deep tissues with real-time software correlators

被引:90
|
作者
Wang, Detian [1 ,2 ]
Parthasarathy, Ashwin B. [1 ]
Baker, Wesley B. [1 ]
Gannon, Kimberly [3 ]
Kavuri, Venki [1 ]
Ko, Tiffany [1 ]
Schenkel, Steven [1 ]
Li, Zhe [1 ,4 ]
Li, Zeren [2 ]
Mullen, Michael T. [3 ]
Detre, John A. [3 ]
Yodh, Arjun G. [1 ]
机构
[1] Univ Penn, Dept Phys & Astron, Philadelphia, PA 19104 USA
[2] China Acad Engn Phys, Inst Fluid Phys, Interdisciplinary Lab Phys & Biomed, Mianyang 621900, Peoples R China
[3] Hosp Univ Penn, Div Stroke & Neurocrit Care, 3400 Spruce St, Philadelphia, PA 19104 USA
[4] Tianjin Univ, State Key Lab Precis Measurement Technol & Instru, Tianjin 300072, Peoples R China
来源
BIOMEDICAL OPTICS EXPRESS | 2016年 / 7卷 / 03期
基金
美国国家卫生研究院;
关键词
DIFFUSE CORRELATION SPECTROSCOPY; COHERENT HEMODYNAMICS SPECTROSCOPY; DYNAMIC CEREBRAL AUTOREGULATION; CEREBROVASCULAR AUTOREGULATION; OPTICAL MEASUREMENT; HUMAN BRAIN; METABOLISM; OXYGENATION; SCATTERING; SURGERY;
D O I
10.1364/BOE.7.000776
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We introduce, validate and demonstrate a new software correlator for high-speed measurement of blood flow in deep tissues based on diffuse correlation spectroscopy (DCS). The software correlator scheme employs standard PC-based data acquisition boards to measure temporal intensity autocorrelation functions continuously at 50 - 100 Hz, the fastest blood flow measurements reported with DCS to date. The data streams, obtained in vivo for typical source-detector separations of 2.5 cm, easily resolve pulsatile heart-beat fluctuations in blood flow which were previously considered to be noise. We employ the device to separate tissue blood flow from tissue absorption/scattering dynamics and thereby show that the origin of the pulsatile DCS signal is primarily flow, and we monitor cerebral autoregulation dynamics in healthy volunteers more accurately than with traditional instrumentation as a result of increased data acquisition rates. Finally, we characterize measurement signal-to-noise ratio and identify count rate and averaging parameters needed for optimal performance. (C) 2016 Optical Society of America
引用
收藏
页码:776 / 797
页数:22
相关论文
共 50 条
  • [1] Real-time catalyst monitoring software
    不详
    HYDROCARBON PROCESSING, 2002, 81 (12): : 27 - 27
  • [2] Real-time optoacoustic monitoring of temperature in tissues
    Larina, IV
    Larin, KV
    Esenaliev, RO
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (15) : 2633 - 2639
  • [3] Real-time optoacoustic monitoring of temperature in tissues
    Esenaliev, RO
    Oraevsky, AA
    Larin, KV
    Larina, IV
    Motamedi, M
    LASER-TISSUE INTERACTION X: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, PROCEEDINGS OF, 1999, 3601 : 268 - 275
  • [4] Real-Time Monitoring of Blood Flow and Intravesical Pressure in the Rat Bladder
    Saito, Motoaki
    Ohmasa, Fumiya
    Tsounapi, Panagiota
    Inoue, Seiya
    Kinoshita, Yukako
    Dimitriadis, Fotios
    Satoh, Keisuke
    LUTS-LOWER URINARY TRACT SYMPTOMS, 2011, 3 (02) : 76 - 78
  • [5] Real-Time Monitoring of Mitochondrial NADH and Microcirculatory Blood Flow in the Spinal Cord
    Simonovich, Maryana
    Barbiro-Michaely, Efrat
    Mayevsky, Avraham
    SPINE, 2008, 33 (23) : 2495 - 2502
  • [6] A software architecture for real-time, embedded monitoring systems
    Caflisch, L
    Savigni, A
    Schettini, R
    Tisato, F
    AVSS 2005: Advanced Video and Signal Based Surveillance, Proceedings, 2005, : 540 - 545
  • [7] Real-Time Monitoring and Visualization Software for OpenFlow Network
    Wassapon, Watanakeesuntorn
    Uthayopas, Putchong
    Chantrapornchai, Chantana
    Ichikawa, Kohei
    2017 15TH INTERNATIONAL CONFERENCE ON ICT AND KNOWLEDGE ENGINEERING (ICT&KE), 2017, : 54 - 58
  • [8] REAL-TIME MONITORING OF BLOOD COAGULATION AND FIBRINOLYSIS
    Ivlev, D.
    Guria, K.
    Uzlova, S.
    Dzhumaeva, S.
    Th, G. Guria
    THROMBOSIS RESEARCH, 2014, 133 : S76 - S76
  • [9] Real-time monitoring for bioaerosols - flow cytometry
    Chen, Pei-Shih
    Li, Chih-Shan
    ANALYST, 2007, 132 (01) : 14 - 16
  • [10] Smart catheter flow sensor for real-time continuous regional cerebral blood flow monitoring
    Li, Chunyan
    Wu, Pei-Ming
    Hartings, Jed A.
    Wu, Zhizhen
    Ahn, Chong H.
    LeDoux, David
    Shutter, Lori A.
    Narayan, Raj K.
    APPLIED PHYSICS LETTERS, 2011, 99 (23)