Cataract surgery following phakic intraocular lens implantation

被引:20
作者
Moshirfar, Majid [1 ]
Mifflin, Mark [1 ]
Wong, Gilbert [1 ]
Chang, JoAnn C. [1 ]
机构
[1] Univ Utah, John A Moran Eye Ctr, Dept Ophthalmol, Cornea & Refract Surg Program, Salt Lake City, UT 84112 USA
关键词
Artiflex lens; Artisan lens; cataract surgery; myopia; phakic intraocular lens; refractive surgery; STAAR implantable Collamer lens; Verisyse lens; AXIAL LENGTH MEASUREMENT; COLLAMER LENS; HIGH MYOPIA; CONTACT-LENS; IOL ICL; MODERATE; DIAMETER; ANGLE;
D O I
10.1097/ICU.0b013e328333ea2f
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of review To review the most recent literature regarding the incidence and pathophysiology of phakic intraocular lens (pIOL) associated cataracts, surgical issues and outcomes of combined pIOL explantation/cataract surgery, and the prevention of cataract formation secondary to pIOLs. Recent findings The overall rate of cataracts secondary to pIOLs is low, but a disproportionate number is associated with posterior chamber pIOLs. All combination pIOL explantation/cataract surgeries resulted in the successful implantation of a posterior chamber intraocular lens in the capsular bag. We present several theories regarding the pathophysiology of anterior subcapsular cataracts secondary to posterior chamber pIOLs. In addition, we present general strategies in performing combination pIOL explantation/cataract surgery. Several methods of preoperative assessment show promise in helping prevent cataracts secondary to pIOLs, including new ultrasound methods for sulcus imaging and preoperative simulations. Summary Although the incidence of cataracts secondary to pIOLs is low, more studies regarding the pathophysiology of this phenomenon and improvement of preoperative assessment are needed, especially for posterior chamber pIOLs.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 22 条
[1]   Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation [J].
Alfonso, Jose F. ;
Lisa, Carlos ;
Palacios, Ana ;
Fernandes, Paulo ;
Gonzalez-Meijome, Jose M. ;
Montes-Mico, Robert .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) :978-983
[2]  
BURATTO L, 2006, P 2006 JOINT M AM AC
[3]   Metaanalysis of cataract development after phakic intraocular lens surgery [J].
Chen, Li-Ju ;
Chang, Yun-Jau ;
Kuo, Jonathan C. ;
Rajagopal, Rama ;
Azar, Dimitri T. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (07) :1181-1200
[4]   Results of cataract surgery after implantation of an iris-fixated phakic intraocular lens [J].
de Vries, Niels E. ;
Tahzib, Nayyirih G. ;
Budo, Camille J. ;
Webers, Carroll A. B. ;
de Boer, Ruben ;
Hendrikse, Fred ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) :121-126
[5]   Foldable Artiflex Phakic Intraocular Lens for the Correction of Myopia Two-Year Follow-up Results of a Prospective European Multicenter Study [J].
Dick, H. Burkhard ;
Budo, Camille ;
Malecaze, Francois ;
Gueell, Josep L. ;
Marinho, Antonio A. P. ;
Nuijts, Rudy M. M. A. ;
Luyten, Gregorius P. M. ;
Menezo, Jose L. ;
Kohnen, Thomas .
OPHTHALMOLOGY, 2009, 116 (04) :671-677
[6]   Vague of preoperative phakic intraocular lens simulation using optical coherence tomography [J].
Doors, Muriel ;
Berendschot, Tos T. J. M. ;
Hendrikse, Fred ;
Webers, Carroll A. B. ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (03) :438-443
[7]   Phakic intraocular lenses [J].
Espandar, Ladan ;
Meyer, Jay J. ;
Moshirfar, Majid .
CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (04) :349-356
[8]   Changes in the crystalline lens resulting from insertion of a phakic IOL (ICL) into the porcine eye [J].
Fujisawa, Kunitoshi ;
Shimizu, Kimiya ;
Uga, Shigekazu ;
Suzuki, Masanobu ;
Nagano, Koichi ;
Murakami, Yuuki ;
Goseki, Hiroko .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (01) :114-122
[9]   Implantable contact lens for moderate to high myopia - Relationship of vaulting to cataract formation [J].
Gonvers, M ;
Bornet, C ;
Othenin-Girard, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :918-924
[10]   Ultrasound axial length measurement in biphakic eyes [J].
Hoffer, KJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :961-965