共 22 条
Hydrocephalus: Ventricular Volume Quantification Using Three-Dimensional Brain CT Data and Semiautomatic Three-Dimensional Threshold-Based Segmentation Approach
被引:8
作者:
Goo, Hyun Woo
[1
,2
]
机构:
[1] Univ Ulsan, Asan Med Ctr, Dept Radiol, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Univ Ulsan, Asan Med Ctr, Res Inst Radiol, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
关键词:
Brain ventricular system;
Computed tomography;
Children;
Hydrocephalus;
Image segmentation;
Volume measurement;
COMPUTED-TOMOGRAPHY;
PEDIATRIC HYDROCEPHALUS;
DOSE REDUCTION;
LINEAR INDEXES;
TUBE CURRENT;
CHILDREN;
HEAD;
D O I:
10.3348/kjr.2020.0671
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Objective: To evaluate the usefulness of the ventricular volume percentage quantified using three-dimensional (3D) brain computed tomography (CT) data for interpreting serial changes in hydrocephalus. Materials and Methods: Intracranial and ventricular volumes were quantified using the semiautomatic 3D threshold-based segmentation approach for 113 brain CT examinations (age at brain CT examination <= 18 years) in 38 patients with hydrocephalus. Changes in ventricular volume percentage were calculated using 75 serial brain CT pairs (time interval 173.6 +/- 234.9 days) and compared with the conventional assessment of changes in hydrocephalus (increased, unchanged, or decreased). A cut-off value for the diagnosis of no change in hydrocephalus was calculated using receiver operating characteristic curve analysis. The reproducibility of the volumetric measurements was assessed using the intraclass correlation coefficient on a subset of 20 brain CT examinations. Results: Mean intracranial volume, ventricular volume, and ventricular volume percentage were 1284.6 +/- 297.1 cm(3), 249.0 +/- 150.8 cm(3), and 19.9 +/- 12.8%, respectively. The volumetric measurements were highly reproducible (intraclass correlation coefficient = 1.0). Serial changes (0.8 +/- 0.6%) in ventricular volume percentage in the unchanged group (n = 28) were significantly smaller than those in the increased and decreased groups (6.8 +/- 4.3% and 5.6 +/- 4.2%, respectively; p = 0.001 and p < 0.001, respectively; n = 11 and n = 36, respectively). The ventricular volume percentage was an excellent parameter for evaluating the degree of hydrocephalus (area under the receiver operating characteristic curve = 0.975; 95% confidence interval, 0.948-1.000; p < 0.001). With a cut-off value of 2.4%, the diagnosis of unchanged hydrocephalus could be made with 83.0% sensitivity and 100.0% specificity. Conclusion: The ventricular volume percentage quantified using 3D brain CT data is useful for interpreting serial changes in hydrocephalus.
引用
收藏
页码:435 / 441
页数:7
相关论文