A Multi-contingency Preventive Control Method for Static Voltage Stability

被引:0
|
作者
Hao, Chen [1 ]
Shi, Yanqiang [1 ]
Shi, Yishan [2 ]
Zhang, Yijing [1 ]
Yi, Zhou [1 ]
Lu, Jianyu [1 ]
Guo, Ruipeng [2 ]
机构
[1] East Branch State Grid Corp China, Shanghai, Peoples R China
[2] Zhejiang Univ, Hangzhou, Peoples R China
关键词
preventive control; multi-contingency; static voltage stability; stability margin; SYSTEMS;
D O I
10.1109/SPIES55999.2022.10082295
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The preventive control for static voltage stability is one of the important contents of the power system's security and stability. A multi-contingency preventive control model for static voltage stability and its corresponding optimal solving algorithm are proposed to enhance the grid's voltage stability when potentially complex contingencies occur. This model aims to minimize the control cost while maintaining the feasibility of normal operating state and keeping proper static voltage stability margin for each contingency considered. The selecting method of the key contingencies set is provided based on the requirement of static voltage stability margin. Meanwhile, the model is optimally solved according to the key contingencies set and then the corresponding preventive control strategies are obtained and implemented. The solving algorithm is further cycled until the voltage stability margins under all contingencies are satisfied the requirements. The validity of the proposed model and algorithm is verified through simulation tests in Eastern China Grid.
引用
收藏
页码:32 / 36
页数:5
相关论文
共 50 条
  • [41] Multi-Contingency Transient Stability-Constrained Optimal Power Flow using Multilayer Feedforward Neural Networks
    King, Robert T. F. Ah
    Tu, Xiaoping
    Dessaint, Louis-A.
    Kamwa, Innocent
    2016 IEEE CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2016,
  • [42] Voltage stability preventive and emergency preventive control using VIPIt sensitivities
    Esaka, T
    Kataoka, Y
    Ohtaka, T
    Iwamoto, S
    2004 IEEE PES POWER SYSTEMS CONFERENCE & EXPOSITION, VOLS 1 - 3, 2004, : 509 - 516
  • [43] Line Stability Indices and Contingency Screening by Sensitivity Factors Based Static Voltage Stability Study
    Jain, Rinkesh A.
    Rathod, Darshan B.
    INNOVATIONS IN INFRASTRUCTURE, 2019, 757 : 129 - 138
  • [44] A preventive control model for static voltage stability considering the active power transfer capabilities of weak branches
    Hu, Xiuqiong, 1600, World Scientific and Engineering Academy and Society, Ag. Ioannou Theologou 17-23, Zographou, Athens, 15773, Greece (09):
  • [45] A preventive control strategy for static voltage stability based on an efficient power plant model of electric vehicles
    Wang, Mingshen
    Mu, Yunfei
    Jia, Hongjie
    Wu, Jianzhong
    Yao, Xiuping
    Yu, Xiaodan
    Ekanayake, Janaka
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2015, 3 (01) : 103 - 113
  • [46] Corrective rescheduling for static voltage stability control
    Arya, LD
    Sakravdia, DK
    Kothari, DP
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2005, 27 (01) : 3 - 12
  • [47] Look-Ahead Based Method for Selection of Preventive Control for Voltage Stability Analysis
    Mansour, M. R.
    Alberto, L. F. C.
    Ramos, R. A.
    2012 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2012, : 469 - 473
  • [48] The Fast Estimation Method of Contingency Voltage Stability with Sensitivity Compensation
    Su, Su
    Tanaka, Kazuyuki
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 347 - +
  • [49] On the role of LTCs in emergency and preventive voltage stability control
    Vournas, CD
    2002 IEEE POWER ENGINEERING SOCIETY WINTER MEETING, VOLS 1 AND 2, CONFERENCE PROCEEDINGS, 2002, : 854 - 859
  • [50] Voltage Stability Preventive Control Using VMPI Sensitivities
    Kataoka, Yoshifumi
    Watanabe, Masato
    Sakaeda, Shingo
    Iwamoto, Shinichi
    ELECTRICAL ENGINEERING IN JAPAN, 2010, 173 (04) : 28 - 37