Total Endovascular Repair With Parallel Stent-Grafts for Postdissection Thoracoabdominal Aneurysm After Prior Proximal Repair

被引:19
作者
Liu, Junjun [1 ,2 ]
Li, Zhenjiang [1 ,3 ]
Feng, Jiaxuan [1 ]
Zhou, Jian [1 ]
Zhao, Zhiqing [1 ]
Bao, Xianhao [1 ]
Zhao, Yuxi [1 ]
Xu, Ziyi [1 ]
Wu, Jianlie [2 ]
Wang, Haofu [2 ]
Feng, Rui [1 ]
Jing, Zaiping [1 ]
机构
[1] Second Mil Med Univ, Changhai Hosp, Dept Vasc Surg, Shanghai, Peoples R China
[2] Qingdao Univ, Affiliated Hosp, Dept Vasc Surg, Qingdao, Shandong, Peoples R China
[3] Zhejiang Univ, Affiliated Hosp 1, Med Sch, Dept Vasc Surg, Hangzhou, Zhejiang, Peoples R China
关键词
aneurysm; aortic dissection; chimney stent-graft; endovascular repair; parallel stent-grafts; postdissection aneurysm; renovisceral arteries; residual aortic dissection; thoracoabdominal aortic aneurysm; B AORTIC DISSECTION; FALSE LUMEN; OUTCOMES; GUIDELINES; MANAGEMENT; THERAPY; TEVAR;
D O I
10.1177/1526602819863779
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To evaluate the safety and efficacy of total endovascular repair with parallel stent-grafts for postoperative residual dissection thoracoabdominal aortic aneurysm (TAAA). Materials and Methods: A retrospective study was undertaken of 21 patients (mean age 64.0 +/- 12.5 years; 17 men) undergoing total endovascular therapy with parallel stent-grafts for postdissection TAAA after prior proximal repair between 2014 and 2016. The preoperative minimum true lumen diameter was 12.3 +/- 4.8 mm and the mean extent of dissection was 248.1 +/- 48.2 mm. Pre-, intra-, and postoperative medical records were reviewed to assess technical success, spinal cord ischemia, patency of target branch arteries, endoleak, and short-term outcomes of this approach. Results: Technical success was achieved in 17 of 21 patients owing to 4 type I endoleaks at the end of the procedures. A total of 70 branch arteries were revascularized and 14 celiac trunks were covered intentionally without reconstruction. Of 7 intraoperative endoleaks, 2 were managed intraoperatively and 5 (4 type I and 1 type II) disappeared spontaneously within 1 month. No spinal cord or abdominal organ or limb ischemia was observed. Mean follow-up was 16.2 +/- 6.1 months. No death or types I or III endoleak occurred during the follow-up; 2 type II endoleaks were observed. Nineteen of the 21 false lumens thrombosed, and the total aortic diameter decreased (57.3 +/- 8.4 to 55.3 +/- 7.4 mm, p<0.01). Three (4.3%) of 70 target branch arteries occluded during follow-up. The cumulative patency of retrogradely and antegradely revascularized branch arteries was 97.3% vs 100% at 12 months and 91.2% vs 100% at 18 months. Conclusion: Total endovascular therapy with parallel stent-grafts could be an effective alternative in treating postdissection TAAA. Further studies with long-term follow-up and larger sample size are recommended to evaluate the technique.
引用
收藏
页码:668 / 675
页数:8
相关论文
共 50 条
  • [21] Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-grafts
    Chang, Catherine K.
    Chuter, Timothy A. M.
    Reilly, Linda M.
    Ota, Maile K.
    Furtado, Andre
    Bucci, Monica
    Wintermark, Max
    Hiramoto, Jade S.
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (03) : 356 - 362
  • [22] Branched Stent-Grafts for Endovascular Repair of Aortic and Iliac Aneurysms
    Chuter, Timothy A. M.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 8 (01) : 56 - 60
  • [23] Comparison of the fixation strength of standard and fenestrated Stent-Grafts for endovascular abdominal aortic aneurysm repair
    Zhou, Samuel S. N.
    How, Thien V.
    Vallabhaneni, S. Rao
    Gilling-Smith, Geoffrey L.
    Brennan, John A.
    Harris, Peter L.
    McWilliams, Richard
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (02) : 168 - 175
  • [24] Performance of BeGraft and BeGraft plus Stent-Grafts as Bridging Devices for Fenestrated Endovascular Aneurysm Repair: An In Vitro Study
    Torsello, Giovanni Federico
    Herten, Monika
    Frank, Andre
    Mueller, Markus
    Jung, Susanne
    Torsello, Giovanni B.
    Austermann, Martin
    JOURNAL OF ENDOVASCULAR THERAPY, 2019, 26 (06) : 787 - 794
  • [25] Use of Fenestrated Stent-Grafts for Preservation of Spinal Artery Flow During Endovascular Repair of Thoracoabdominal Aortic Disease
    D'Oria, Mario
    Wanhainen, Anders
    Mani, Kevin
    ANNALS OF VASCULAR SURGERY, 2021, 70 : 566.e15 - 566.e20
  • [26] Mycotic aneurysms of the thoracic aorta: Repair with use of endovascular stent-grafts
    Semba, CP
    Sakai, T
    Slonim, SM
    Razavi, MK
    Kee, ST
    Jorgensen, MJ
    Hagberg, RC
    Lee, GK
    Mitchell, RS
    Miller, DC
    Dake, MD
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (01) : 33 - 40
  • [27] Late Complications after Endovascular Thoracoabdominal Aneurysm Repair
    Eagleton, Matthew J.
    Greenberg, Roy K.
    SEMINARS IN VASCULAR SURGERY, 2009, 22 (02) : 87 - 92
  • [28] Results of Endovascular Repair of Abdominal Aortic Aneurysms with an Unfavorable Proximal Neck Using Large Stent-Grafts
    Zayed, Hany A.
    Bell, Rachel E.
    Clough, Rachel E.
    Thomas, Stephen
    Sabharwal, Tarun
    Reidy, John F.
    Carrell, Tom W.
    Taylor, Peter R.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (06) : 1161 - 1164
  • [29] BIFURCATED STENT-GRAFTS FOR ENDOVASCULAR REPAIR OF ABDOMINAL AORTIC-ANEURYSM - PRELIMINARY CASE-REPORTS
    CHUTER, TAM
    DONAYRE, C
    WENDT, G
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1994, 8 (07): : 800 - 802
  • [30] Comparison of Physician-Modified Fenestrated/Branched Stent-Grafts and Hybrid Visceral Debranching Plus Stent-Graft Placement for Complex Thoracoabdominal Aortic Aneurysm Repair
    Yang, Guangmin
    Zhang, Ming
    Muzepper, Mehmutjan
    Du, Xiaolong
    Wang, Wei
    Liu, Cheng
    Qiao, Tong
    Zhou, Min
    Li, Xiaoqiang
    JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (05) : 749 - 756