Powder Flow Measurement Comparison between two ring shear testers

被引:0
|
作者
Jaeda, Hind [1 ]
Knop, Kjaus [1 ]
Kleinebudde, Peter [1 ]
机构
[1] Univ Dusseldorf, Inst Pharmaceut & Biopharmaceut, D-40225 Dusseldorf, Germany
来源
PHARMAZEUTISCHE INDUSTRIE | 2009年 / 71卷 / 07期
关键词
Binary mixtures; Consolidation stress; Flowability; Glidants; Ring shear testers; Unconfined yield strength; BULK SOLIDS;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Shear testers are the internationally recognized means to measure the flow properties of cohesive bulk solids. They were used lately for assessment of the flow behaviour of different pharmaceutical excipients and active ingredients in many pharmaceutical research groups. In this work two automated Schulze ring shear testers were compared. The Schulze testers are direct shear testers with rotational displacement and unlimited strain. The Schulze shear tester RST-01.pc (larger tester) and the Schulze shear tester RST-XS (smaller tester) were compared. In this study a 200 ml shear cell was used for the measurements carried out on the RST-01.pc tester while a 30 ml shear cell was used for the measurements on the RST-XS tester. A set of binary mixtures of different active ingredients and excipients were prepared and a total of 189 measurements were carried out on each tester. Both testers led to low ffc values with cohesive mixtures and high ffc values with easy flowing mixtures. However, ffc values more than 10 were not used because these values were highly fluctuating; besides they still refer to a free flowing mixture. The easy flowing mixtures showed a broader ffc scatter while the more cohesive powders showed a narrower scatter on both testers. Comparing the ffc values of both testers showed that the results were well correlated with a correlation coefficient r = 0.97. However, the smaller (RST-XS) tester showed slightly lower ffc values compared to the larger (RST-01.pc) tester. For comparative tests this effect does not play a role as long as the same ring shear tester with the same shear cell size is used throughout the measurements. However, an advantage of the smaller (RST-XS) tester is that a smaller amount of bulk solid is required for the test.
引用
收藏
页码:1221 / +
页数:7
相关论文
共 50 条
  • [1] A comparison between powder flow property testers
    Salehi, Hamid
    Barletta, Diego
    Poletto, Massimo
    PARTICUOLOGY, 2017, 32 : 10 - 20
  • [2] Measurements on cohesive powder with two biaxial shear testers
    Janssen, RJM
    Zetzener, H
    CHEMICAL ENGINEERING & TECHNOLOGY, 2003, 26 (02) : 147 - 151
  • [3] A comparison between powder flow property testers? (vol 32, pg 10, 2017)
    Salehi, Hamid
    Barletta, Diego
    Poletto, Massimo
    PARTICUOLOGY, 2023, 76 : 140 - 140
  • [4] A comparison between powder flow property testers (vol 32, pg 10, 2017)
    Salehi, Hamid
    Barletta, Diego
    Poletto, Massimo
    PARTICUOLOGY, 2023, 76 : 140 - 140
  • [5] Comparison of three rotational shear cell testers: Powder flowability and bulk density
    Koynov, Sara
    Glasser, Benjamin
    Muzzio, Fernando
    POWDER TECHNOLOGY, 2015, 283 : 103 - 112
  • [6] Round robin test on ring shear testers
    Schulze, Dietmar
    ADVANCED POWDER TECHNOLOGY, 2011, 22 (02) : 197 - 202
  • [7] FLOW PROPERTIES OF POWDERS USING 4 TESTERS - MEASUREMENT, COMPARISON AND ASSESSMENT
    KAMATH, S
    PURI, VM
    MANBECK, HB
    HOGG, R
    POWDER TECHNOLOGY, 1993, 76 (03) : 277 - 289
  • [8] Impact of Shear History on Powder Flow Characterization Using a Ring Shear Tester
    Swize, Tatum
    Osei-Yeboah, Frederick
    Peterson, Matthew L.
    Boulas, Pierre
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 108 (01) : 750 - 754
  • [9] MEASUREMENT OF FLOW PROPERTIES OF TABLET GRANULES WITH RING SHEAR CELL
    NYQVIST, H
    BRODIN, A
    CEDERVALL, B
    NICKLASSON, M
    ACTA PHARMACEUTICA SUECICA, 1981, 18 (02): : 100 - 100
  • [10] Precision of pharmaceutical powder flow measurement using ring shear tester: High variability is inherent to powders with low cohesion
    Leung, Lap Yin
    Mao, Chen
    Chen, Li Ping
    Yang, Chia-Yi
    POWDER TECHNOLOGY, 2016, 301 : 920 - 926