Push-out tests on demountable shear connectors of steel-concrete composite structures

被引:63
|
作者
Kozma, A. [1 ]
Odenbreit, C. [1 ]
Braun, M., V [1 ]
Veljkovic, M. [2 ]
Nijgh, M. P. [2 ]
机构
[1] Univ Luxembourg, Res Unit Engn Sci, Luxembourg, Luxembourg
[2] Delft Univ Technol, Fac Civil Engn & Geosci, Delft, Netherlands
关键词
Demountable shear connectors; Push-out tests; Metal decking; Circular economy; Shear capacity; Experimental study; BEHAVIOR; PERFORMANCE;
D O I
10.1016/j.istruc.2019.05.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Circular Economy refers to a move from linear business models, in which products are manufactured from raw materials, used and then discarded, to circular business models where products or parts are re-used, remanufactured or recycled. Structural steel is highly compatible with this concept; however, when steel-concrete composite structures are used, recycling becomes difficult and the potential for reuse is lost. In order to make steel-concrete composite structures reusable, bolted connections should replace the commonly used welded headed studs. Furthermore, the reusable parts should be designed to withstand repeated use. This paper presents a desktop study and the corresponding laboratory experiments on demountable shear connectors that facilitate recyclability and even provide the potential for reusing complete structural elements. In the Laboratory of Steel and Composite Structures of the University of Luxembourg 15 push-out tests have been carried out using different bolted connection systems suitable for multiple use. The shear connectors have been evaluated based on their shear strength, stiffness, slip capacity, ductility and ability of demounting. The investigated systems included pre-stressed and epoxy resin injection bolts, solid slabs and solid slabs in combination with profiled steel sheeting. The results showed that the tested demountable shear connections could provide higher shear resistance than conventional shear connections. The critical failure mode was the shear failure of the bolts, which is a brittle failure. There was no visible damage observed on the connected members. The application of epoxy resin in the hole clearance resulted in lower slip capacity. The outcome provides an important basis for the justification of the forthcoming enhancement and validation of numerical models of the demountable shear connections. The failure behaviour, the observed damages and the resulting ability of the elements for re-use are discussed in detail.
引用
收藏
页码:45 / 54
页数:10
相关论文
共 50 条
  • [1] Push-out tests on demountable shear connectors of steel-concrete composite structures
    Kozma, A.
    Odenbreit, C.
    Braun, M., V
    Veljkovic, M.
    Nijgh, M. P.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 549 - 556
  • [2] HIGH TEMPERATURE PUSH-OUT TESTS ON DEMOUNTABLE SHEAR CONNECTORS OF STEEL-CONCRETE COMPOSITE BEAMS
    Mansilla, Roberto
    Espinós, Ana
    Payá-Faforteza, Ignacio
    Odenbreit, Christoph
    Romero, Manuel L.
    ce/papers, 2023, 6 (3-4) : 2074 - 2079
  • [3] Push-out tests of demountable shear connectors for sustainable composite structures
    Kiraly, Krisztian
    Dunai, Laszlo
    Calado, Luis
    Balazs Kocsis, Andras
    STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2024, 17 (04): : 200 - 211
  • [4] Characterization of the elevated temperature behaviour of demountable shear connectors in steel-concrete composite beams through push-out tests
    Mansilla, R.
    Espinos, A.
    Odenbreit, C.
    Paya-Zaforteza, I.
    Romero, M. L.
    STRUCTURES, 2024, 59
  • [5] Push-out tests of demountable headed stud shear connectors in steel-UHPC composite structures
    Wang, Jun-Yan
    Guo, Jun-Yuan
    Jia, Liang-Jiu
    Chen, Shi-Ming
    Dong, Yang
    COMPOSITE STRUCTURES, 2017, 170 : 69 - 79
  • [6] Push-out tests on stud shear connectors with constrained structure of steel-concrete composite beams
    Qia, Jingjing
    Xie, Zuwei
    Cao, Hua
    Huang, Zhi
    Lv, Weirong
    Shi, Weihua
    STRUCTURAL ENGINEERING AND MECHANICS, 2022, 83 (06) : 789 - 798
  • [7] Push-out tests of shear connectors in U-shaped steel-concrete composite girder
    Liu, Yong
    Guo, Lanhui
    Shi, Jun
    Wang, Jingfeng
    STRUCTURES, 2021, 31 : 769 - 780
  • [8] Push-out tests of shear connectors for new fully assembled steel-concrete composite beams
    Hou H.-T.
    Zang Z.-Y.
    Lu Y.-X.
    Liu J.-W.
    Ji K.-F.
    Wang Y.-M.
    Gongcheng Lixue/Engineering Mechanics, 2020, 37 (02): : 201 - 210
  • [9] Push-out tests of straight shear connectors based on steel-concrete adherence
    Diogenes, H. J. F.
    El Debs, A. L. H. C.
    El Debs, M. K.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, RESILIENCE AND SUSTAINABILITY, 2012, : 2960 - 2966
  • [10] Demountable shear connectors – constructional details and push-out tests
    Király, Krisztián
    Dunai, László
    Calado, Luis
    Kocsis, András Balázs
    ce/papers, 2023, 6 (3-4) : 53 - 58