Swept Source Optical Coherence Tomography Compared to Ultrasound and Biomicroscopy for Diagnosis of Posterior Vitreous Detachment

被引:12
作者
Wang, Marlene D. [1 ]
Truong, Cecile [1 ]
Mammo, Zaid [1 ]
Hussnain, Syed Amal [1 ]
Chen, Royce W. S. [1 ]
机构
[1] Columbia Univ, Edward S Harkness Eye Inst, Irving Med Ctr, Dept Ophthalmol, New York, NY 10032 USA
关键词
optical coherence tomography; swept source; posterior vitreous detachment; IN-VIVO; VISUALIZATION;
D O I
10.2147/OPTH.S297307
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Biomicroscopy, B-scan ultrasound imaging, and SD-OCT are all modalities used to characterize a posterior vitreous detachment (PVD). Our objective is to assess the precision of the diagnosis of PVD by SS-OCT. Methods: This prospective observational study examines ninety-five eyes of forty-nine patients with biomicroscopy, B-scan ultrasound, and SS-OCT for the presence or absence of a complete PVD. All SS-OCT images were reviewed by two retina specialists (RWSC, ZM). All three diagnostic methods were evaluated for agreement by Cohen's kappa statistic. Results: The inter-rater reliability between retina specialists reading the SS-OCT images was 97.9% (kappa = 0.957). Agreement on PVD status between SS-OCT and biomicroscopy was 85.3% (kappa = 0.711). Agreement between SS-OCT and B-scan ultrasound was 83.2% (kappa = 0.667). Agreement between B-scan ultrasound and biomicroscopy was 87.4% (kappa = 0.743). Conclusion: For the diagnosis of complete PVD, SS-OCT allows for high accuracy and agreement between graders.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 20 条
[1]   REAL-TIME FULL-DEPTH VISUALIZATION OF POSTERIOR OCULAR STRUCTURES Comparison Between Full-Depth Imaging Spectral Domain Optical Coherence Tomography and Swept-Source Optical Coherence Tomography [J].
Barteselli, Giulio ;
Bartsch, Dirk-Uwe ;
Weinreb, Robert N. ;
Camacho, Natalia ;
Nezgoda, Joseph T. ;
Marvasti, Amir H. ;
Freeman, William R. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (06) :1153-1161
[2]   Is Optical Coherence Tomography a Useful Tool to Objectively Detect Actual Posterior Vitreous Adhesion Status? [J].
Bertelmann, Thomas ;
Goos, Christina ;
Sekundo, Walter ;
Schulze, Stephan ;
Mennel, Stefan .
CASE REPORTS IN OPHTHALMOLOGICAL MEDICINE, 2016, 2016
[3]   Swept source optical coherence tomography of the posterior vitreous after pars plana vitrectomy [J].
Chen, Kevin C. ;
Jung, Jesse J. ;
Engelbert, Michael .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (11) :2041-2043
[4]   Accuracy of Spectral-Domain OCT of the Macula for Detection of Complete Posterior Vitreous Detachment [J].
Hwang, Eileen S. ;
Kraker, Jessica A. ;
Griffin, Kim J. ;
Sebag, J. ;
Weinberg, David, V ;
Kim, Judy E. .
OPHTHALMOLOGY RETINA, 2020, 4 (02) :148-153
[5]   Vitreous Changes in High Myopia Observed by Swept-Source Optical Coherence Tomography [J].
Itakura, Hirotaka ;
Kishi, Shoji ;
Li, Danjie ;
Nitta, Keisuke ;
Akiyama, Hideo .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (03) :1447-1452
[6]   Observation of Posterior Precortical Vitreous Pocket Using Swept-Source Optical Coherence Tomography [J].
Itakura, Hirotaka ;
Kishi, Shoji ;
Li, Danjie ;
Akiyama, Hideo .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (05) :3102-3107
[7]  
Johnson Mark W, 2012, Retina, V32 Suppl 2, pS174, DOI 10.1097/IAE.0b013e31825bef62
[8]   Posterior Vitreous Detachment: Evolution and Complications of Its Early Stages [J].
Johnson, Mark W. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (03) :371-382
[9]   Evaluation of a posterior vitreous detachment: a comparison of biomicroscopy, B-scan ultrasonography and optical coherence tomography to surgical findings with chromodissection [J].
Kicova, Nadia ;
Bertelmann, Thomas ;
Irle, Sebastian ;
Sekundo, Walter ;
Mennel, Stefan .
ACTA OPHTHALMOLOGICA, 2012, 90 (04) :E264-E268
[10]  
Kishi Shoji, 2016, Taiwan J Ophthalmol, V6, P58, DOI 10.1016/j.tjo.2015.09.002