Relationship between N95 Amplitude of Pattern Electroretinogram and Optical Coherence Tomography Angiography in Open-Angle Glaucoma

被引:5
作者
Lee, Taekjune [1 ]
Seo, Du Ri [1 ]
Kim, Joo Yeon [1 ]
Choi, Wungrak [1 ]
Lee, Sang Yeop [1 ,2 ]
Lee, Jun Mo [3 ]
Seong, Gong Je [1 ]
Kim, Chan Yun [1 ]
Bae, Won Hyoung [1 ]
机构
[1] Yonsei Univ, Inst Vis Res, Dept Ophthalmol, Coll Med, 50-1 Yonsei Ro, Seoul 03722, South Korea
[2] Yonsei Univ, Yongin Severance Hosp, Dept Ophthalmol, Coll Med, 363 Dongbaekjukjeon Daero, Yongin 16995, South Korea
[3] Siloam Eye Hosp, 181 Deungchon Ro, Seoul 07668, South Korea
基金
新加坡国家研究基金会;
关键词
pattern electroretinogram; optical coherence tomography angiography; open-angle glaucoma; N95; amplitude; MACULAR VESSEL DENSITY; OCULAR HYPERTENSION; PERIPAPILLARY; HEALTHY; PERFUSION;
D O I
10.3390/jcm9123854
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The pattern electroretinogram (PERG) is useful to detect retinal ganglion cell (RGC) damage in patients with glaucoma. Optical coherence tomography angiography (OCTA) measures retinal vessel density (VD), which is known to be reduced in glaucoma. There may be correlations between parameters of the PERG and OCTA in open-angle glaucoma (OAG). Methods: In total, 95 eyes of 95 OAG patients and 102 eyes of 102 normal controls were included in this study. N35, P50, and N95 latency along with P50 and N95 amplitude were obtained using the PERG. Retinal VD was measured around the peripapillary and macular area according to the ETDRS grid (concentric circles with diameters of 1, 3, and 6 mm), which is named a center (<= 1 mm), an inner (1-3 mm), an outer (3-6 mm), and a full (<= 6 mm) area. Pearson correlation analysis was done between parameters, and partial correlation analysis was done after adjusting confounding factors. Results: P50 amplitude, N95 amplitude, and VD of most measured areas were significantly lower in the OAG group compared to the normal group. N95 amplitude showed a statistically significant correlation with parameters of optical coherence tomography and visual field, peripapillary outer and full VD, and macular outer and full VD even after adjusting confounding factors. There was no significant correlation between parameters in the normal group. Conclusions: N95 amplitude was associated with structural and functional change including VD reduction in OAG. Microvascular alterations may be associated with dysfunctional changes of RGC recorded by the PERG in OAG.
引用
收藏
页数:13
相关论文
共 38 条
[1]   S-cone, L+M-cone, and pattern, electroretinograms in ocular hypertension and glaucoma [J].
Aldebasi, YH ;
Drasdo, N ;
Morgan, JE ;
North, RV .
VISION RESEARCH, 2004, 44 (24) :2749-2756
[2]   Pattern ERG as an early glaucoma indicator in ocular hypertension: A long-term, prospective study [J].
Bach, Michael ;
Unsoeld, Anke S. ;
Philippin, Heiko ;
Staubach, Flemming ;
Maier, Philip ;
Walter, Hans S. ;
Bomer, Thomas G. ;
Funk, Jens .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (11) :4881-4887
[3]   ISCEV standard for clinical pattern electroretinography (PERG): 2012 update [J].
Bach, Michael ;
Brigell, Mitchell G. ;
Hawlina, Marko ;
Holder, Graham E. ;
Johnson, Mary A. ;
McCulloch, Daphne L. ;
Meigen, Thomas ;
Viswanathan, Suresh .
DOCUMENTA OPHTHALMOLOGICA, 2013, 126 (01) :1-7
[4]   Pattern Electroretinogram in Glaucoma Suspects: New Findings from a Longitudinal Study [J].
Bode, Sebastian F. N. ;
Jehle, Thomas ;
Bach, Michael .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) :4300-4306
[5]   Optic Disc Perfusion in Primary Open Angle and Normal Tension Glaucoma Eyes Using Optical Coherence Tomography-Based Microangiography [J].
Bojikian, Karine D. ;
Chen, Chieh-Li ;
Wen, Joanne C. ;
Zhang, Qinqin ;
Xin, Chen ;
Gupta, Divakar ;
Mudumbai, Raghu C. ;
Johnstone, Murray A. ;
Wang, Ruikang K. ;
Chen, Philip P. .
PLOS ONE, 2016, 11 (05)
[6]   Diagnostic Accuracy of Pattern Electroretinogram Optimized for Glaucoma Detection [J].
Bowd, Chistopher ;
Vizzeri, Gianmarco ;
Tafreshi, Ali ;
Zangwill, Linda M. ;
Sample, Pamela A. ;
Weinreb, Robert N. .
OPHTHALMOLOGY, 2009, 116 (03) :437-443
[7]   Pattern electroretinogram changes in patients with primary open-angle glaucoma in correlation with visual field and optical coherence tomography changes [J].
Elohary, Asmaa M. ;
Elbedewy, Hazem A. ;
Saad, Hisham A. ;
Eid, Tarek M. .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (06) :1362-1369
[8]   Association of Macular and Circumpapillary Microvasculature with Visual Field Sensitivity in Advanced Glaucoma [J].
Ghahari, Elham ;
Bowd, Christopher ;
Zangwill, Linda M. ;
Proudfoot, James ;
Hasenstab, Kyle A. ;
Hou, Huiyuan ;
Penteado, Rafaella C. ;
Manalastas, Patricia Isabel C. ;
Moghimi, Sasan ;
Shoji, Takuhei ;
Christopher, Mark ;
Yarmohammadi, Adeleh ;
Weinreb, Robert N. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 204 :51-61
[9]   Relationship between Macular Vessel Density and Focal Electroretinograms in Early Normal Tension Glaucoma [J].
Honda, Hakuei ;
Anraku, Ayako ;
Ishida, Kyoko ;
Enomoto, Nobuko ;
Tomita, Goji .
CURRENT EYE RESEARCH, 2019, 44 (07) :753-759
[10]   The pattern electroretinogram in glaucoma patients with confirmed visual field deficits [J].
Hood, DC ;
Xu, L ;
Thienprasiddhi, P ;
Greenstein, VC ;
Odel, JG ;
Grippo, TM ;
Liebmann, JM ;
Ritch, R .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) :2411-2418