机构:
Aston Univ, Life & Hlth Sci, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, EnglandUniv Plymouth, Sch Hlth Profess, Plymouth PL4 8AA, Devon, England
Naroo, Shehzad A.
[2
]
Davies, Leon N.
论文数: 0引用数: 0
h-index: 0
机构:
Aston Univ, Life & Hlth Sci, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, EnglandUniv Plymouth, Sch Hlth Profess, Plymouth PL4 8AA, Devon, England
Davies, Leon N.
[2
]
Shah, Sunil
论文数: 0引用数: 0
h-index: 0
机构:
Aston Univ, Life & Hlth Sci, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, England
Midland Eye, Solihull, W Midlands, EnglandUniv Plymouth, Sch Hlth Profess, Plymouth PL4 8AA, Devon, England
Shah, Sunil
[2
,3
]
论文数: 引用数:
h-index:
机构:
Buckhurst, Hetal
[1
]
Kingsnorth, Alec
论文数: 0引用数: 0
h-index: 0
机构:
Aston Univ, Life & Hlth Sci, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, EnglandUniv Plymouth, Sch Hlth Profess, Plymouth PL4 8AA, Devon, England
Kingsnorth, Alec
[2
]
Drew, Tom
论文数: 0引用数: 0
h-index: 0
机构:
Aston Univ, Life & Hlth Sci, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, EnglandUniv Plymouth, Sch Hlth Profess, Plymouth PL4 8AA, Devon, England
Drew, Tom
[2
]
Wolffsohn, James S.
论文数: 0引用数: 0
h-index: 0
机构:
Aston Univ, Life & Hlth Sci, Ophthalm Res Grp, Birmingham B4 7ET, W Midlands, EnglandUniv Plymouth, Sch Hlth Profess, Plymouth PL4 8AA, Devon, England
PURPOSE: To assess the validity and repeatability of the Aston Halometer. SETTING: University clinic, United Kingdom. DESIGN: Prospective, repeated-measures experimental study. METHODS: The halometer comprises a bright light-emitting-diode (LED) glare source in the center of an iPad4. Letters subtending 0.21 (similar to 0.3 logMAR) were moved centrifugally from the LED in 0.05 degree steps in 8 orientations separated by 45 degrees for each of 4 contrast levels (1000, 500, 100, and 25 Weber contrast units [C-w]) in random order. Bangerter occlusion foils were inserted in front of the right eye to simulate monocular glare conditions in 20 subjects (mean age 27.7 +/- 3.1 years). Subjects were positioned 2 meters from the screen in a dark room with the iPad controlled from an iPhone via Bluetooth operated by the researcher. The C-Quant straylight meter was also used with each of the foils to measure the level of straylight over the retina. Halometry and straylight repeatability was assessed at a second visit. RESULTS: Halo size increased with the different occlusion foils and target contrasts (F = 29.564, P<.001) as expected and in a pattern similar to straylight measures (F = 80.655, P<0.001). Lower contrast letters showed better sensitivity but larger glare-obscured areas, resulting in ceiling effects caused by the screen's field-of-view, with 500 C-w, being the best compromise. Intraobserver and interobserver repeatability of the Aston Halometer was good (500C(w): 0.84 to 0.93 and 0.53 to 0.73) and similar to the straylight meter. CONCLUSION: The halometer provides a sensitive, repeatable way of quantifying a patient-recognized form of disability glare in multiple orientations to add objectivity to subjectively reported discomfort glare. (C) 2015 ASCRS and ESCRS
机构:
Innovat Vis Prod Inc, Cty Of New Castle, DE 19810 USA
Moscow Helmholtz Res Inst Eye Disorders, Moscow 103064, RussiaInnovat Vis Prod Inc, Cty Of New Castle, DE 19810 USA
Babizhayev, Mark A.
;
Minasyan, Hayk
论文数: 0引用数: 0
h-index: 0
机构:
Innovat Vis Prod Inc, Cty Of New Castle, DE 19810 USAInnovat Vis Prod Inc, Cty Of New Castle, DE 19810 USA
Minasyan, Hayk
;
Richer, Stuart P.
论文数: 0引用数: 0
h-index: 0
机构:
DVA Med Ctr, Eye Clin, N Chicago, IL USA
Rosalind Franklin Univ Med & Sci, Dept Family & Prevent Med, N Chicago, IL USAInnovat Vis Prod Inc, Cty Of New Castle, DE 19810 USA
机构:
Innovat Vis Prod Inc, Cty Of New Castle, DE 19810 USA
Moscow Helmholtz Res Inst Eye Disorders, Moscow 103064, RussiaInnovat Vis Prod Inc, Cty Of New Castle, DE 19810 USA
Babizhayev, Mark A.
;
Minasyan, Hayk
论文数: 0引用数: 0
h-index: 0
机构:
Innovat Vis Prod Inc, Cty Of New Castle, DE 19810 USAInnovat Vis Prod Inc, Cty Of New Castle, DE 19810 USA
Minasyan, Hayk
;
Richer, Stuart P.
论文数: 0引用数: 0
h-index: 0
机构:
DVA Med Ctr, Eye Clin, N Chicago, IL USA
Rosalind Franklin Univ Med & Sci, Dept Family & Prevent Med, N Chicago, IL USAInnovat Vis Prod Inc, Cty Of New Castle, DE 19810 USA