High prevalence of Legionella in non-passenger merchant vessels

被引:3
作者
Collins, S. L. [1 ]
Stevenson, D. [1 ]
Mentasti, M. [2 ]
Shaw, A. [3 ]
Johnson, A. [4 ]
Crossley, L. [5 ]
Willis, C. [6 ]
机构
[1] Publ Hlth England, Natl Infect Serv, Biosafety Air & Water Microbiol Grp, Porton Down SP4 0JG, England
[2] Publ Hlth England, Resp & Vaccine Preventable Bacteria Reference Uni, London, England
[3] Belfast City Hosp, Belfast Hlth & Social Care Trust, Northern Ireland Publ Hlth Lab, Belfast, Antrim, North Ireland
[4] Publ Hlth England, Natl Infect Serv, Food Water & Environm Microbiol Lab, London, England
[5] Manchester Port Hlth Author, Runcorn, Cheshire, England
[6] Publ Hlth England, Natl Infect Serv, Food Water & Environm Microbiol Lab, Porton Down, England
关键词
Legionella; water-borne infections; water (safe); water (quality); SEQUENCE-BASED SCHEME; LEGIONNAIRES-DISEASE; CRUISE SHIPS; WATER; OUTBREAKS; AEROSOLS; RISK;
D O I
10.1017/S0950268816002715
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
There is a paucity of information on the risk from potable water in non-passenger merchant vessels (NPMVs) particularly with regard to Legionella and other bacteria. This retrospective study examined water samples from 550 NPMVs docked in eight UK ports. A total of 1027 samples from 412 NPMVs were examined for total aerobic colony counts (ACC), coliforms, Escherichia coli and enterococci; 41% of samples yielded ACC above the action level (> 1 x 10(3) c.f.u./ml) and 4.5% contained actionable levels (> 1 c.f.u./100 ml) of faecal indicator bacteria. Eight hundred and three samples from 360 NPMVs were cultured specifically for Legionella and 58% of vessels proved positive for these organisms with 27% of samples showing levels greater than the UK upper action limit of 1 x 10(3) c.f.u./l. Cabin showers (49%) and hospital shower (45%) were frequently positive. A subset of 106 samples was analysed by quantitative polymerase chain reaction for Legionella and identified a further 11 Legionella-positive NPMVs, returning a negative predictive value of 100%. There was no correlation between NPMV age or size and any microbial parameters (P > 0.05). Legionella pneumophila serogroup 1 was isolated from 46% of NPMVs and sequence-based typing of 17 isolates revealed four sequence types (STs) previously associated with human disease. These data raise significant concerns regarding the management of microbial and Legionella risks on board NPMVs and suggest that better guidance and compliance are required to improve control.
引用
收藏
页码:647 / 655
页数:9
相关论文
共 45 条
[11]  
[Anonymous], 1998, 117311998 ISO
[12]   Prevalence study of Legionella spp. contamination in ferries and cruise ships [J].
Azara, A ;
Piana, A ;
Sotgiu, G ;
Dettori, M ;
Deriu, MG ;
Masia, MD ;
Are, BM ;
Muresu, E .
BMC PUBLIC HEALTH, 2006, 6 (1)
[13]  
Bartram J., 2009, Water Safety Plan manual: Step-by-step risk management for drinking water suppliers
[14]  
Bartram Jamie, 2007, P1
[15]   Legionella bacteria in shower aerosols increase the risk of Pontiac fever among older people in retirement homes [J].
Bauer, M. ;
Mathieu, L. ;
Deloge-Abarkan, M. ;
Remen, T. ;
Tossa, P. ;
Hartemann, P. ;
Zmirou-Navier, D. .
JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 2008, 62 (10) :913-920
[16]   Legionnaires' disease outbreak associated with a cruise liner, August 2003:: epidemiological and microbiological findings [J].
Beyrer, K. ;
Lai, S. ;
Dreesman, J. ;
Lee, J. V. ;
Joseph, C. ;
Harrison, T. ;
Surman-Lee, S. ;
Lueck, C. ;
Brodhun, B. ;
Buchholz, U. ;
Windorfer, A. .
EPIDEMIOLOGY AND INFECTION, 2007, 135 (05) :802-810
[17]   AEROSOLS CONTAINING LEGIONELLA-PNEUMOPHILA GENERATED BY SHOWER HEADS AND HOT-WATER FAUCETS [J].
BOLLIN, GE ;
PLOUFFE, JF ;
PARA, MF ;
HACKMAN, B .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1985, 50 (05) :1128-1131
[18]   A small outbreak of Legionnaires' disease in a cargo ship under repair [J].
Caylà, JA ;
Maldonado, R ;
González, J ;
Pellicer, T ;
Ferrer, D ;
Pelaz, C ;
Gracia, J ;
Baladrón, B ;
Plaséncia, A .
EUROPEAN RESPIRATORY JOURNAL, 2001, 17 (06) :1322-1327
[19]   Real-time PCR to supplement gold-standard culture-based detection of Legionella in environmental samples [J].
Collins, S. ;
Jorgensen, F. ;
Willis, C. ;
Walker, J. .
JOURNAL OF APPLIED MICROBIOLOGY, 2015, 119 (04) :1158-1169
[20]  
David S, 2016, GENOME RES