Patient-specific quality assurance method for VMAT treatment delivery

被引:113
作者
Schreibmann, Eduard [1 ]
Dhabaan, Anees [1 ]
Elder, Eric [1 ]
Fox, Tim [1 ]
机构
[1] Emory Univ, Sch Med, Dept Radiat Oncol, Atlanta, GA 30322 USA
关键词
CONE-BEAM CT; A-SI EPIDS; DOSE RECONSTRUCTION; RADIATION-THERAPY; MLC; CALIBRATION; IMRT; VERIFICATION; RAPIDARC; ARC;
D O I
10.1118/1.3213085
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Volumetric modulated arc therapy (VMAT) is a system for intensity-modulated radiotherapy treatment delivery that achieves high dose conformality by optimizing the dose rate, gantry speed, and the leaf positions of the dynamic multileaf collimator (DMLC). The aim of this work is to present a practical approach for patient-specific volumetric reconstruction of the dose delivered of a VMAT treatment using the DMLC and treatment controller log (Dynalog) files. The accuracy of VMAT delivery was analyzed for five prostate patients. For each patient, a clinical treatment was delivered and values recorded in the log files for the gantry angle, dose rate, and leaf positions were converted to a new DICOM-compliant plan using a custom-developed software system. The plan was imported in a treatment planning system and the dose distribution was recreated on the original CT by simply recomputing the dose. Using the standard evaluation tools, it is straightforward to assess if reconstructed dose meets clinical endpoints, as well as to compare side-by-side reconstructed and original plans. The study showed that log files can be directly used for dose reconstruction without resorting to phantom measurements or setups. In all cases, analysis of the leaf positions showed a maximum error of -0.26 mm (mean of 0.15 mm). Gantry angle deviation was less than 1 S and the total MU was within 0.5 from the planned value. Differences between the reconstructed and the intended dose matrices were less than 1.46% for all cases. Measurements using the MATRIXX system in a phantom were used to validate the dosimetric accuracy of the proposed method, with an agreement of at least 96% in all pixels as measured using the gamma index. The methodology provides a volumetric evaluation of the dose reconstructed by VMAT plans which is easily achieved by automated analysis of Dynalog files without additional measurements or phantom setups. This process provides a valuable platform for adaptive therapy in the future. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3213085]
引用
收藏
页码:4530 / 4535
页数:6
相关论文
共 26 条
[1]   Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration [J].
Baker, SJK ;
Budgell, GJ ;
MacKay, RI .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (07) :1377-1392
[2]   Analysis of the measurement precision of an amorphous silicon EPID used for MLC leaf position quality control and the long-term calibration stability of an optically controlled MLC [J].
Budgell, G. J. ;
Clarke, M. F. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (15) :N297-N306
[3]   Improving IMRT quality control efficiency using an amorphous silicon electronic portal imager [J].
Budgell, GJ ;
Zhang, Q ;
Trouncer, RJ ;
Mackay, RI .
MEDICAL PHYSICS, 2005, 32 (11) :3267-3278
[4]   Use of an amorphous silicon EPID for measuring MLC calibration at varying gantry angle [J].
Clarke, M. F. ;
Budgell, G. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (02) :473-485
[5]   A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy [J].
Cozzi, Luca ;
Dinshaw, Ketayun Ardeshir ;
Shrivastava, Shyam Kishore ;
Mahantshetty, Umesh ;
Engineer, Reena ;
Deshpande, Deepak Dattatray ;
Jamema, S. V. ;
Vanetti, Eugenio ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Fogliata, Antonella .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (02) :180-191
[6]   Intensity modulation with photons for benign intracranial tumours: A planning comparison of volumetric single arc, helical arc and fixed gantry techniques [J].
Fogliata, Antonella ;
Clivio, Alessandro ;
Nicolini, Giorgia ;
Vanetti, Eugenio ;
Cozzi, Luca .
RADIOTHERAPY AND ONCOLOGY, 2008, 89 (03) :254-262
[7]   Calibration and quality assurance for rounded leaf-end MLC systems [J].
Graves, MN ;
Thompson, AV ;
Martel, MK ;
McShan, DL ;
Fraass, BA .
MEDICAL PHYSICS, 2001, 28 (11) :2227-2233
[8]   Dosimetric verification of RapidArc treatment delivery [J].
Korreman, Stine ;
Medin, Joakim ;
Kjaer-Kristoffersen, Flemming .
ACTA ONCOLOGICA, 2009, 48 (02) :185-191
[9]   The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy [J].
Lee, Louis ;
Mao, Weihua ;
Xing, Lei .
MEDICAL PHYSICS, 2008, 35 (11) :5019-5029
[10]   Validation of dynamic MLC-controller log files using a two-dimensional diode array [J].
Li, JG ;
Dempsey, JF ;
Ding, L ;
Liu, CR ;
Palta, JR .
MEDICAL PHYSICS, 2003, 30 (05) :799-805