Investigating volumetric repainting to mitigate interplay effect on 4D robustly optimized lung cancer plans in pencil beam scanning proton therapy

被引:21
作者
Rana, Suresh [1 ,2 ,3 ,4 ]
Rosenfeld, Anatoly B. [4 ]
机构
[1] Oklahoma Proton Ctr, Dept Med Phys, Oklahoma City, OK 73142 USA
[2] Baptist Hlth South Florida, Dept Radiat Oncol, Miami Canc Inst, Miami, FL 33139 USA
[3] Florida Int Univ, Herbert Wertheim Coll Med, Dept Radiat Oncol, Miami, FL 33199 USA
[4] Univ Wollongong, Ctr Med Radiat Phys CMRP, Wollongong, NSW, Australia
关键词
4D robust optimization; interplay effect; lung cancer; Monte Carlo; pencil beam scanning;
D O I
10.1002/acm2.13183
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The interplay effect between dynamic pencil proton beams and motion of the lung tumor presents a challenge in treating lung cancer patients in pencil beam scanning (PBS) proton therapy. The main purpose of the current study was to investigate the interplay effect on the volumetric repainting lung plans with beam delivery in alternating order ("down" and "up" directions), and explore the number of volumetric repaintings needed to achieve acceptable lung cancer PBS proton plan. Method The current retrospective study included ten lung cancer patients. The total dose prescription to the clinical target volume (CTV) was 70 Gy(RBE) with a fractional dose of 2 Gy(RBE). All treatment plans were robustly optimized on all ten phases in the 4DCT data set. The Monte Carlo algorithm was used for the 4D robust optimization, as well as for the final dose calculation. The interplay effect was evaluated for both the nominal (i.e., without repainting) as well as volumetric repainting plans. The interplay evaluation was carried out for each of the ten different phases as the starting phases. Several dosimetric metrics were included to evaluate the worst-case scenario (WCS) and bandwidth based on the results obtained from treatment delivery starting in ten different breathing phases. Results The number of repaintings needed to meet the criteria 1 (CR1) of target coverage (D-95% >= 98% and D-99% >= 97%) ranged from 2 to 10. The number of repaintings needed to meet the CR1 of maximum dose (Delta D-1% < 1.5%) ranged from 2 to 7. Similarly, the number of repaintings needed to meet CR1 of homogeneity index (Delta HI < 0.03) ranged from 3 to 10. For the target coverage region, the number of repaintings needed to meet CR1 of bandwidth (<100 cGy) ranged from 3 to 10, whereas for the high-dose region, the number of repaintings needed to meet CR1 of bandwidth (<100 cGy) ranged from 1 to 7. Based on the overall plan evaluation criteria proposed in the current study, acceptable plans were achieved for nine patients, whereas one patient had acceptable plan with a minor deviation. Conclusion The number of repaintings required to mitigate the interplay effect in PBS lung cancer (tumor motion < 15 mm) was found to be highly patient dependent. For the volumetric repainting with an alternating order, a patient-specific interplay evaluation strategy must be adopted. Determining the optimal number of repaintings based on the bandwidth and WCS approach could mitigate the interplay effect in PBS lung cancer treatment.
引用
收藏
页码:107 / 118
页数:12
相关论文
共 34 条
[1]   Impact of varying planning parameters on proton pencil beam scanning dose distributions in four commercial treatment planning systems [J].
Alshaikhi, Jailan ;
Doolan, Paul J. ;
D'Souza, Derek ;
Holloway, Stacey McGowan ;
Amos, Richard A. ;
Royle, Gary .
MEDICAL PHYSICS, 2019, 46 (03) :1150-1162
[2]   Motion in radiotherapy: particle therapy [J].
Bert, C. ;
Durante, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16) :R113-R114
[3]   Quantification of interplay effects of scanned particle beams and moving targets [J].
Bert, Christoph ;
Groezinger, Sven O. ;
Rietzel, Eike .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (09) :2253-2265
[4]   Consensus Guidelines for Implementing Pencil-Beam Scanning Proton Therapy for Thoracic Malignancies on Behalf of the PTCOG Thoracic and Lymphoma Subcommittee [J].
Chang, Joe Y. ;
Zhang, Xiaodong ;
Knopf, Antje ;
Li, Heng ;
Mori, Shinichiro ;
Dong, Lei ;
Lu, Hsiao-Ming ;
Liu, Wei ;
Badiyan, Shahed N. ;
Both, Stephen ;
Meijers, Arturs ;
Lin, Liyong ;
Flampouri, Stella ;
Li, Zuofeng ;
Umegaki, Kikuo ;
Simone, Charles B., II ;
Zhu, Xiaorong R. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (01) :41-50
[5]   Four-dimensional Plan Optimization for the Treatment of Lung Tumors Using Pencil-beam Scanning Proton Radiotherapy [J].
Cummings, David ;
Tang, Shikui ;
Ichter, William ;
Wang, Peng ;
Sturgeon, Jared D. ;
Lee, Andrew K. ;
Chang, Chang .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2018, 10 (08)
[6]   Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters [J].
Dowdell, S. ;
Grassberger, C. ;
Sharp, G. C. ;
Paganetti, H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (12) :4137-4156
[7]   Effectiveness of different rescanning techniques for scanned proton radiotherapy in lung cancer patients [J].
Engwall, E. ;
Glimelius, L. ;
Hynning, E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (09)
[8]   4D robust optimization including uncertainties in time structures can reduce the interplay effect in proton pencil beam scanning radiation therapy [J].
Engwall, Erik ;
Fredriksson, Albin ;
Glimelius, Lars .
MEDICAL PHYSICS, 2018, 45 (09) :4020-4029
[9]   Motion mitigation for lung cancer patients treated with active scanning proton therapy [J].
Grassberger, Clemens ;
Dowdell, Stephen ;
Sharp, Greg ;
Paganetti, Harald .
MEDICAL PHYSICS, 2015, 42 (05) :2462-2469
[10]   Motion Interplay as a Function of Patient Parameters and Spot Size in Spot Scanning Proton Therapy for Lung Cancer [J].
Grassberger, Clemens ;
Dowdell, Stephen ;
Lomax, Antony ;
Sharp, Greg ;
Shackleford, James ;
Choi, Noah ;
Willers, Henning ;
Paganetti, Harald .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (02) :380-386