Investigating volumetric repainting to mitigate interplay effect on 4D robustly optimized lung cancer plans in pencil beam scanning proton therapy

被引:19
|
作者
Rana, Suresh [1 ,2 ,3 ,4 ]
Rosenfeld, Anatoly B. [4 ]
机构
[1] Oklahoma Proton Ctr, Dept Med Phys, Oklahoma City, OK 73142 USA
[2] Baptist Hlth South Florida, Dept Radiat Oncol, Miami Canc Inst, Miami, FL 33139 USA
[3] Florida Int Univ, Herbert Wertheim Coll Med, Dept Radiat Oncol, Miami, FL 33199 USA
[4] Univ Wollongong, Ctr Med Radiat Phys CMRP, Wollongong, NSW, Australia
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2021年 / 22卷 / 03期
关键词
4D robust optimization; interplay effect; lung cancer; Monte Carlo; pencil beam scanning;
D O I
10.1002/acm2.13183
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The interplay effect between dynamic pencil proton beams and motion of the lung tumor presents a challenge in treating lung cancer patients in pencil beam scanning (PBS) proton therapy. The main purpose of the current study was to investigate the interplay effect on the volumetric repainting lung plans with beam delivery in alternating order ("down" and "up" directions), and explore the number of volumetric repaintings needed to achieve acceptable lung cancer PBS proton plan. Method The current retrospective study included ten lung cancer patients. The total dose prescription to the clinical target volume (CTV) was 70 Gy(RBE) with a fractional dose of 2 Gy(RBE). All treatment plans were robustly optimized on all ten phases in the 4DCT data set. The Monte Carlo algorithm was used for the 4D robust optimization, as well as for the final dose calculation. The interplay effect was evaluated for both the nominal (i.e., without repainting) as well as volumetric repainting plans. The interplay evaluation was carried out for each of the ten different phases as the starting phases. Several dosimetric metrics were included to evaluate the worst-case scenario (WCS) and bandwidth based on the results obtained from treatment delivery starting in ten different breathing phases. Results The number of repaintings needed to meet the criteria 1 (CR1) of target coverage (D-95% >= 98% and D-99% >= 97%) ranged from 2 to 10. The number of repaintings needed to meet the CR1 of maximum dose (Delta D-1% < 1.5%) ranged from 2 to 7. Similarly, the number of repaintings needed to meet CR1 of homogeneity index (Delta HI < 0.03) ranged from 3 to 10. For the target coverage region, the number of repaintings needed to meet CR1 of bandwidth (<100 cGy) ranged from 3 to 10, whereas for the high-dose region, the number of repaintings needed to meet CR1 of bandwidth (<100 cGy) ranged from 1 to 7. Based on the overall plan evaluation criteria proposed in the current study, acceptable plans were achieved for nine patients, whereas one patient had acceptable plan with a minor deviation. Conclusion The number of repaintings required to mitigate the interplay effect in PBS lung cancer (tumor motion < 15 mm) was found to be highly patient dependent. For the volumetric repainting with an alternating order, a patient-specific interplay evaluation strategy must be adopted. Determining the optimal number of repaintings based on the bandwidth and WCS approach could mitigate the interplay effect in PBS lung cancer treatment.
引用
收藏
页码:107 / 118
页数:12
相关论文
共 30 条
  • [1] Mitigation of motion effects in pencil-beam scanning-Impact of repainting on 4D robustly optimized proton treatment plans for hepatocellular carcinoma
    Siregar, Hilda
    Baumer, Christian
    Blanck, Oliver
    Chan, Mark
    Engwall, Erik
    Plaude, Sandija
    Spaan, Bernhard
    Timmermann, Beate
    Wulff, Jorg
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (01): : 63 - 73
  • [2] 4DMRI-based investigation on the interplay effect for pencil beam scanning proton therapy of pancreatic cancer patients
    Dolde, Kai
    Zhang, Ye
    Chaudhri, Naved
    David, Christian
    Kachelriess, Marc
    Lomax, Antony John
    Naumann, Patrick
    Saito, Nami
    Weber, Damien Charles
    Pfaffenberger, Asja
    RADIATION ONCOLOGY, 2019, 14 (1)
  • [3] Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy
    Pfeiler, Tina
    Baeumer, Christian
    Engwall, Erik
    Geismar, Dirk
    Spaan, Bernhard
    Timmermann, Beate
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2018, 28 (02): : 121 - 133
  • [4] Impact of errors in spot size and spot position in robustly optimized pencil beam scanning proton-based stereotactic body radiation therapy (SBRT) lung plans
    Rana, Suresh
    Rosenfeld, Anatoly B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 147 - 154
  • [5] Motion effects in proton treatments of hepatocellular carcinoma-4D robustly optimised pencil beam scanning plans versus double scattering plans
    Pfeiler, Tina
    Khalil, Dalia Ahmad
    Ayadi, Myriam
    Baumer, Christian
    Blanck, Oliver
    Chan, Mark
    Engwall, Erik
    Geismar, Dirk
    Peters, Sarah
    Plaude, Sandija
    Spaan, Bernhard
    Timmermann, Beate
    wulff, Joerg
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23)
  • [6] 4DMRI-based investigation on the interplay effect for pencil beam scanning proton therapy of pancreatic cancer patients
    Kai Dolde
    Ye Zhang
    Naved Chaudhri
    Christian Dávid
    Marc Kachelrieß
    Antony John Lomax
    Patrick Naumann
    Nami Saito
    Damien Charles Weber
    Asja Pfaffenberger
    Radiation Oncology, 14
  • [7] Technical Note: Investigating interplay effects in pencil beam scanning proton therapy with a 4D XCAT phantom within the RayStation treatment planning system
    den Boer, Erik
    Wulff, Joerg
    Maeder, UIf
    Engwall, Erik
    Baeumer, Christian
    Perko, Zoltan
    Timmermann, Beate
    MEDICAL PHYSICS, 2021, 48 (03) : 1448 - 1455
  • [8] A study of the beam-specific interplay effect in proton pencil beam scanning delivery in lung cancer
    Kang, Minglei
    Huang, Sheng
    Solberg, Timothy D.
    Mayer, Rulon
    Thomas, Andy
    Teo, Boon-Keng Kevin
    McDonough, James E.
    Simone, Charles B., II
    Lin, Liyong
    ACTA ONCOLOGICA, 2017, 56 (04) : 531 - 540
  • [9] 4D robust optimization including uncertainties in time structures can reduce the interplay effect in proton pencil beam scanning radiation therapy
    Engwall, Erik
    Fredriksson, Albin
    Glimelius, Lars
    MEDICAL PHYSICS, 2018, 45 (09) : 4020 - 4029
  • [10] Impact of magnetic field regulation in conjunction with the volumetric repainting technique on the spot positions and beam range in pencil beam scanning proton therapy
    Rana, Suresh
    Bennouna, Jaafar
    Gutierrez, Alonso N.
    Rosenfeld, Anatoly B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 124 - 131