Retrospective Continuous-Time Blood Glucose Estimation in Free Living Conditions with a Non-Invasive Multisensor Device

被引:10
作者
Acciaroli, Giada [1 ]
Zanon, Mattia [2 ]
Facchinetti, Andrea [1 ]
Caduff, Andreas [2 ]
Sparacino, Giovanni [1 ]
机构
[1] Univ Padua, Dept Informat Engn, I-35131 Padua, Italy
[2] Biovotion AG, CH-8008 Zurich, Switzerland
关键词
diabetes; continuous glucose monitoring; non-invasive; multisensor; SYSTEM;
D O I
10.3390/s19173677
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Even if still at an early stage of development, non-invasive continuous glucose monitoring (NI-CGM) sensors represent a promising technology for optimizing diabetes therapy. Recent studies showed that the Multisensor provides useful information about glucose dynamics with a mean absolute relative difference (MARD) of 35.4% in a fully prospective setting. Here we propose a method that, exploiting the same Multisensor measurements, but in a retrospective setting, achieves a much better accuracy. Data acquired by the Multisensor during a long-term study are retrospectively processed following a two-step procedure. First, the raw data are transformed to a blood glucose (BG) estimate by a multiple linear regression model. Then, an enhancing module is applied in cascade to the regression model to improve the accuracy of the glucose estimation by retrofitting available BG references through a time-varying linear model. MARD between the retrospectively reconstructed BG time-series and reference values is 20%. Here, 94% of values fall in zone A or B of the Clarke Error Grid. The proposed algorithm achieved a level of accuracy that could make this device a potential complementary tool for diabetes management and also for guiding prediabetic or nondiabetic users through life-style changes.
引用
收藏
页数:12
相关论文
共 29 条
[1]   Multiparameter techniques for non-invasive measurement of blood glucose [J].
Amaral, Carlos F. ;
Brischwein, Martin ;
Wolf, Bernhard .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (01) :12-16
[2]  
[Anonymous], 2013, 151972013 ISO
[3]   Noninvasive glucose sensing [J].
Arnold, MA ;
Small, GW .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5429-5439
[4]  
Barrios L., 2018, P 12 EAI INT C PERV
[5]   Evaluating the accuracy of heart rate sensors based on photoplethysmography for in-the-wild analysis [J].
Barrios, Liliana ;
Oldrati, Pietro ;
Santini, Silvia ;
Lutterotti, Andreas .
PROCEEDINGS OF THE 13TH EAI INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING TECHNOLOGIES FOR HEALTHCARE (PERVASIVEHEALTH 2019), 2019, :251-261
[6]   The Wearing Comfort and Acceptability of Ambulatory Physical Activity Monitoring Devices in Soldiers [J].
Beeler, Nadja ;
Roos, Lilian ;
Delves, Simon K. ;
Veenstra, Bertil J. ;
Friedl, Karl ;
Buller, Mark J. ;
Wyss, Thomas .
IISE TRANSACTIONS ON OCCUPATIONAL ERGONOMICS & HUMAN FACTORS, 2018, 6 (01) :1-10
[7]   In vivo evaluation of a chip based near infrared sensor for continuous glucose monitoring [J].
Ben Mohammadi, Lhoucine ;
Klotzbuecher, Thomas ;
Sigloch, Susanne ;
Welzel, Knut ;
Goeddel, Michael ;
Pieber, Thomas R. ;
Schaupp, Lukas .
BIOSENSORS & BIOELECTRONICS, 2014, 53 :99-104
[8]   Non-invasive glucose monitoring in patients with diabetes: A novel system based on impedance spectroscopy [J].
Caduff, A. ;
Dewarrat, F. ;
Talary, M. ;
Stalder, G. ;
Heinemann, L. ;
Feldman, Yu. .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (05) :598-604
[9]  
Caduff Andreas, 2018, J Diabetes Sci Technol, V12, P562, DOI 10.1177/1932296817750932
[10]  
Caduff Andreas, 2015, J Diabetes Sci Technol, V9, P865, DOI 10.1177/1932296815579459