Multiple dual-mode countercurrent chromatography applied to chiral separations using a (S)-naproxen derivative as chiral selector

被引:63
作者
Rubio, Nuria [1 ,2 ]
Ignatova, Svetlana [3 ]
Minguillon, Cristina [1 ,2 ]
Sutherland, Ian A. [3 ]
机构
[1] PCB, Inst Res Biomed IRB Barcelona, E-08028 Barcelona, Spain
[2] Univ Barcelona, Fac Pharm, Quim Farmaceut Lab, E-08028 Barcelona, Spain
[3] Brunel Univ, BIB, Uxbridge UB8 3PH, Middx, England
关键词
Countercurrent chromatography; Multiple dual-mode; Enantiomer separation; Chiral selector; CENTRIFUGAL PARTITION CHROMATOGRAPHY; ENANTIOMER SEPARATION; CURRENT EXTRACTION;
D O I
10.1016/j.chroma.2009.10.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Countercurrent chromatography (CCC) is a liquid-liquid chromatographic technique without a solid support. Several alternative elution modes can be applied to take advantage of the special nature of the liquid stationary phase. Among these dual-mode (DM) and multiple dual-mode (MDM) consist of switching alternatively between Reversed and Normal Phase operation during the experiment (once for DM and several times for MDM). In this paper, MDM has been applied to the chiral CCC separations of two racemic mixtures, (+/-)-N-(3,4-cis-3-decyl-1,2,3,4-tetrahydrophenanthren-4-yl)-3,5-dinitrobenzamide and N-(3,5-dinitrobenzoyl)-(+/-)-leucine, using (S)-naproxen N,N-diethylamide as chiral selector (CS). Although the behaviour of the two analytes differed, improved resolution factors were successfully obtained. Results are rationalized on the basis of the distinct partition behaviour of the CS/enantiomer complexes in the biphasic system. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:8505 / 8511
页数:7
相关论文
共 20 条
[1]   Dual-mode high-speed counter-current chromatography:: retention, resolution and examples [J].
Agnely, M ;
Thiébaut, D .
JOURNAL OF CHROMATOGRAPHY A, 1997, 790 (1-2) :17-30
[2]  
[Anonymous], SEX ED
[3]  
Berthod A., 2002, COUNTERCURRENT CHROM, V38
[4]   Preparative separation of gambogic acid and its C-2 epimer using recycling high-speed counter-current chromatography [J].
Bin Han, Quan ;
Song, Jing Zheng ;
Qiao, Chun Feng ;
Wong, Lina ;
Xu, Hong Xi .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) :298-301
[5]  
Conway WD., 1990, COUNTERCURRENT CHROM
[6]   Multiple dual-mode centrifugal partition chromatography, a semi-continuous development mode for routine laboratory-scale purifications [J].
Delannay, Eldra ;
Toribio, Alix ;
Boudesocque, Leslie ;
Nuzillard, Jean-Marc ;
Zeches-Hanrot, Monique ;
Dardennes, Emmanuel ;
Le Dour, Gwennael ;
Sapi, Janos ;
Renault, Jean-Hugues .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) :45-51
[7]   Enantiomer separation by counter-current chromatography -: Optimisation and drawbacks in the use of L-proline derivatives as chiral selectors [J].
Delgado, B ;
Pérez, E ;
Santano, MC ;
Minguillón, C .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1092 (01) :36-42
[8]   Vancomycin as a chiral selector in centrifugal partition chromatography [J].
Duret, P ;
Foucault, A ;
Margraff, R .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (02) :295-312
[9]   Enantiomer separation by countercurrent chromatography using cinchona alkaloid derivatives as chiral selectors [J].
Franco, P ;
Blanc, J ;
Oberleitner, WR ;
Maier, NM ;
Lindner, W ;
Minguillón, C .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4175-4183
[10]   Intermittent counter-current extraction as an alternative approach to purification of Chinese herbal medicine [J].
Hewitson, Peter ;
Ignatova, Svetlana ;
Ye, Haoyu ;
Chen, Lijuan ;
Sutherland, Ian .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (19) :4187-4192