Textile Electrodes: Influence of Knitting Construction and Pressure on the Contact Impedance

被引:38
作者
Euler, Luisa [1 ,2 ]
Guo, Li [1 ]
Persson, Nils-Krister [1 ,2 ]
机构
[1] Univ Boras, Dept Text Technol, Polymer E Text, SE-50190 Boras, Sweden
[2] Univ Boras, Smart Text Technol Lab, Smart Text, SE-50190 Boras, Sweden
关键词
impedance spectroscopy; textile electrodes; electrode construction; pressure influence; electrical stimulation; biomedical signal monitoring; ELECTRICAL NERVE-STIMULATION; ELECTROTHERAPY;
D O I
10.3390/s21051578
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Textile electrodes, also called textrodes, for biosignal monitoring as well as electrostimulation are central for the emerging research field of smart textiles. However, so far, only the general suitability of textrodes for those areas was investigated, while the influencing parameters on the contact impedance related to the electrode construction and external factors remain rather unknown. Therefore, in this work, six different knitted electrodes, applied both wet and dry, were compared regarding the influence of specific knitting construction parameters on the three-electrode contact impedance measured on a human forearm. Additionally, the influence of applying pressure was investigated in a two-electrode setup using a water-based agar dummy. Further, simulation of an equivalent circuit was used for quantitative evaluation. Indications were found that the preferred electrode construction to achieve the lowest contact impedance includes a square shaped electrode, knitted with a high yarn density and, in the case of dry electrodes, an uneven surface topography consisting of loops, while in wet condition a smooth surface is favorable. Wet electrodes are showing a greatly reduced contact impedance and are therefore to be preferred over dry ones; however, opportunities are seen for improving the electrode performance of dry electrodes by applying pressure to the system, thereby avoiding disadvantages of wet electrodes with fluid administration, drying-out of the electrolyte, and discomfort arising from a "wet feeling".
引用
收藏
页码:1 / 23
页数:21
相关论文
共 50 条
[1]   Utility of silver-coated fabrics as electrodes in electrotherapy applications [J].
Ali, Azam ;
Baheti, Vijay ;
Militky, Jiri ;
Khan, Zaman .
JOURNAL OF APPLIED POLYMER SCIENCE, 2018, 135 (23)
[2]   Investigating the performance of dry textile electrodes for wearable end-uses [J].
An, Xiang ;
Tangsirinaruenart, Orathai ;
Stylios, George K. .
JOURNAL OF THE TEXTILE INSTITUTE, 2019, 110 (01) :151-158
[3]   A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking [J].
An, Xiang ;
Stylios, George K. .
MATERIALS, 2018, 11 (10)
[4]   Comparison of two different techniques of electrotherapy on myofascial pain [J].
Ardiç, F ;
Sarhus, M ;
Topuz, O .
JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2002, 16 (01) :11-16
[5]   Textile Electrocardiogram (ECG) Electrodes for Wearable Health Monitoring [J].
Arquilla, Katya ;
Webb, Andrea K. ;
Anderson, Allison P. .
SENSORS, 2020, 20 (04)
[6]  
Awan F, 2019, INT SYMP ELECTR ELEC, P59, DOI [10.1109/ISEE2.2019.8920937, 10.1109/isee2.2019.8920937]
[7]   Characterization of textile electrodes and conductors using standardized measurement setups [J].
Beckmann, L. ;
Neuhaus, C. ;
Medrano, G. ;
Jungbecker, N. ;
Walter, M. ;
Gries, T. ;
Leonhardt, S. .
PHYSIOLOGICAL MEASUREMENT, 2010, 31 (02) :233-247
[8]   Electrical performance of PEDOT: PSS-based textile electrodes for wearable ECG monitoring: a comparative study [J].
Castrillon, Reinel ;
Perez, Jairo J. ;
Andrade-Caicedo, Henry .
BIOMEDICAL ENGINEERING ONLINE, 2018, 17
[9]   Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording [J].
Chen, Yun-Hsuan ;
Op de Beeck, Maaike ;
Vanderheyden, Luc ;
Carrette, Evelien ;
Mihajlovic, Vojkan ;
Vanstreels, Kris ;
Grundlehner, Bernard ;
Gadeyne, Stefanie ;
Boon, Paul ;
Van Hoof, Chris .
SENSORS, 2014, 14 (12) :23758-23780
[10]   Heart Monitoring Garments Using Textile Electrodes for Healthcare Applications [J].
Cho, Hyun-Seung ;
Koo, Su-Min ;
Lee, Joohyeon ;
Cho, Hakyung ;
Kang, Da-Hye ;
Song, Ha-Young ;
Lee, Jeong-Whan ;
Lee, Kang-Hwi ;
Lee, Young-Jae .
JOURNAL OF MEDICAL SYSTEMS, 2011, 35 (02) :189-201