A flow injection-ETAAS system for the on-line determination of total and dissolved silica in waters

被引:13
作者
Burguera, M [1 ]
Burguera, JL [1 ]
Carrero, P [1 ]
Rondón, C [1 ]
机构
[1] Univ Los Andes, Fac Sci, IVAIQUIM, Merida 5101A, Venezuela
关键词
silicon; water; flow injection; ETAAS;
D O I
10.1016/S0039-9140(02)00205-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work total (Si-tot) and 'soluble' or reactive (Si-sol) concentrations of silicon in natural and tap waters were sequentially determined by electrothermal atomic absorption spectrometry (ETAAS). First, samples were on-line diluted based on the merging-zone principle in order to allow the determination of Si-tot within the 300-1000 mugSi l(-1) range. After the dilution process, a sub-sample was collected in the capillary of a sampling arm assembly (SAA). Thereafter, samples were subject to a precipitation/dissolution process in order to allow the determination of Si-sol within the 280-850 mugSi l(-1) . Si-sol was precipitated with ammonium chloride and collected on the walls of a knotted coil. The precipitate was dissolved with ammonium molybdate in an acidic medium (HNO3) and a sub-sample was then collected in the SAA. In both cases, 10 mul volumes of the sub-sample were injected into the atomizer with the previous introduction of 20 ng of Eu as chemical modifier (10 mul) by the spectrometer autosampler. The recovery values obtained with natural waters spiked samples were over 46% and the agreement between observed and certified samples values was good. The proportion of Si-sol in comparison with the Si-tot was high (85-95%) in most natural waters. The precision of the method was 2.4-3.5 and 4.5-6.2% (n = 10) for the determination of Si-tot and Si-sol, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1157 / 1166
页数:10
相关论文
共 22 条
[1]  
BAILEY RA, 1978, CHEM ENV, P407
[2]  
BLOK NI, 1955, ANAL CHIMICA CALITAT, P403
[3]   Determination of beryllium in natural and waste waters using on-line flow-injection preconcentration by precipitation/dissolution for electrothermal atomic absorption spectrometry [J].
Burguera, JL ;
Burguera, M ;
Rondón, C ;
Carrero, P ;
Brunetto, MR ;
de Peña, YP .
TALANTA, 2000, 52 (01) :27-37
[4]  
BURGUERA JL, UNPUB
[5]   A TIME-BASED INJECTOR APPLIED TO THE FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF BORON IN PLANT MATERIALS AND SOILS [J].
CARRERO, P ;
BURGUERA, JL ;
BURGUERA, M ;
RIVAS, C .
TALANTA, 1993, 40 (12) :1967-1974
[6]  
CLESCERI LS, 1992, METODOS NORMALIZADOS, P204
[7]   DETERMINATION OF SILICON BY FLAME PHOTOMETRY AND ATOMIC FLUORESCENCE SPECTROSCOPY WITH A SEPARATED NITROUS OXIDE-ACETYLENE FLAME [J].
DAGNALL, RM ;
KIRKBRIG.GF ;
WEST, TS ;
WOOD, R .
ANALYTICA CHIMICA ACTA, 1969, 47 (03) :407-&
[8]   FLOW-INJECTION ONLINE COPRECIPITATION PRECONCENTRATION FOR ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
FANG, ZL ;
DONG, LP .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :439-445
[10]   Spectrophotometric determination of silicate in rain and aerosols by flow analysis [J].
Giacomelli, MC ;
Largiuni, O ;
Piccardi, G .