ARTIFICIAL INTELLIGENCE-POWERED MEASUREMENT OF LEFT VENTRICULAR EJECTION FRACTION USING A HANDHELD ULTRASOUND DEVICE

被引:26
作者
Filipiak-Strzecka, Dominika [1 ]
Kasprzak, Jaroslaw D. [1 ]
Wejner-Mik, Paulina [1 ]
Szymczyk, Ewa [1 ]
Wdowiak-Okrojek, Katarzyna [1 ]
Lipiec, Piotr [1 ]
机构
[1] Med Univ Lodz, Bieganski Hosp, Dept Cardiol, Kniaziewicza 1-5, PL-91347 Lodz, Poland
关键词
Key Words; Handheld ultrasound devices; Left ventricular ejection fraction; Automated echocardiographic assessment; CHRONIC HEART-FAILURE; SIZE IMAGING DEVICE; POCKET ECHOCARDIOGRAPH; EUROPEAN ASSOCIATION; CLINICAL UTILITY; RECOMMENDATIONS; DEFIBRILLATOR; VALIDATION; INFARCTION; DIAGNOSIS;
D O I
10.1016/j.ultrasmedbio.2020.12.003
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
aim of this study was to assess the accuracy of an algorithm for automated measurement of left ventricular ejection fraction (LVEF) available on handheld ultrasound devices (HUDs). One hundred twelve patients admitted to the cardiology department underwent assessment performed with an HUD. In each case, the four-chamber apical view was obtained, and LVEF was calculated with LVivo software. Subsequently, during the examination performed with the use of the stationary echocardiograph, the 3-D measurement of LVEF was recorded. The average LVEFs measured with LVivo and the 3-D reference method were 46 ? 14% and 48 ? 14%, respectively. The correlation between the measurements obtained with the HUD and 3-D evaluation was high (r = 0.92, 95% confidence interval: 0.87-0.95, p < 0.0001). The mean difference between the LVEF obtained with LVivo and the 3-D LVEF was not significant (mean difference: -0.61%, 95% confidence interval: -1.89 to 0.68, p = 0.31). The LVivo software despite its limitations is capable of the accurate LVEF measurement when the acquired views are of at least good imaging quality. (E-mail: dominika.filipiak@gmail.com) ? 2020 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1120 / 1125
页数:6
相关论文
共 32 条
[1]  
Bienstock S, FULLY AUTOMATED ECHO
[2]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[3]   A novel two-dimensional echocardinarraphic image analysis system using artificial intelligence-learned pattern recognition for rapid automated ejection fraction [J].
Cannesson, Maxime ;
Tanabe, Masaki ;
Suffoletto, Matthew S. ;
McNamara, Dennis M. ;
Madan, Shobhit ;
Lacomis, Joan M. ;
Gorcsan, John, III .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (02) :217-226
[4]   The use of handheld ultrasound devices: a position statement of the European Association of Cardiovascular Imaging (2018 update) [J].
Cardim, Nuno ;
Dalen, Havard ;
Voigt, Jens-Uwe ;
Ionescu, Adrian ;
Price, Susanna ;
Neskovic, Atexsandar N. ;
Edvardsen, Thor ;
Gatderisi, Maurizio ;
Sicari, Rosa ;
Donal, Erwan ;
Stefanidis, Atexandros ;
Delgado, Victoria ;
Zamorano, Jose ;
Popescu, Bogdan A. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 (03) :245-252
[5]  
Colclough A, 2017, HERZ, V42, P255, DOI 10.1007/s00059-016-4531-4
[6]   The Pocket Echocardiograph: Validation and Feasibility [J].
Culp, Benjamin C. ;
Mock, Jonathan D. ;
Chiles, Christopher D. ;
Culp, William C., Jr. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (07) :759-764
[7]  
DeCara J M, 2003, Eur J Echocardiogr, V4, P141, DOI 10.1053/euje.2002.0617
[8]   Use of hand-carried ultrasound devices to augment the accuracy of medical student bedside cardiac diagnoses [J].
DeCara, JM ;
Kirkpatrick, JN ;
Spencer, KT ;
Ward, RP ;
Kasza, K ;
Furlong, K ;
Lang, RM .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (03) :257-263
[9]   The pocket echocardiograph: a useful new tool? [J].
Egan, Margaret ;
Ionescu, A. .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2008, 9 (06) :721-725
[10]   Pocket-size echocardiograph - a valuable tool for non-experts or just a portable device for echocardiographers? [J].
Filipiak-Strzecka, D. ;
John, B. ;
Kasprzak, J. D. ;
Michalski, B. ;
Lipiec, P. .
ADVANCES IN MEDICAL SCIENCES, 2013, 58 (01) :67-72