Active Control of Counter-Rotating Open Rotor Interior Noise in a Domier 728 Experimental Aircraft: Optimised Sensor Placement

被引:2
作者
Haase, T. [1 ,2 ]
Unruh, O. [1 ,2 ]
机构
[1] German Aerosp Ctr DLR, Dept Adapt Syst, Lilienthalpl 7, D-38108 Braunschweig, Germany
[2] Tech Univ Carolo Wilhelmina Braunschweig, Inst Adaptron & Funct Integrat, Langer Kamp 6, D-38106 Braunschweig, Germany
关键词
SOUND;
D O I
10.3813/AAA.918952
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
For the next generation of aircraft, new engine and fuselage concepts are investigated because of the increasing demand for fuel efficiency and the CO2/NOx restrictions declared by the European Union. A lightweight design of civil aircraft combined with efficient engines like the counter-rotating open rotor (CROR) is a key technology to reach these ambitious goals. Especially in the lower frequency range, where the CROR blade-passing frequencies (BPF's) are dominating the acoustic response, the transmission loss of lightweight structures is typically poor. Active control techniques was tested on plates and beams to increase the system performance in terms of global vibration or sound power reduction. Yet to the authors' best knowledge, only very little work has been conducted to establish sensor or actuator position optimisation on a complex aircraft structure. The presented paper investigates the potential of a sensor position optimisation on a Dornier 728 experimental aircraft of the German Aerospace center (DLR). This experimental aircraft provides a real fuselage structure and the multi-sinusoidal CROR excitation is induced by a 112-channel loud speaker array. The system model of a fuselage segment is experimentally identified, a sensor optimisation is established and compared to empirically placed sensor configurations. The sensor optimisation includes the simulation of an multiple-input multiple output (MIMO) active feedforward vibration controller and the resulting sound radiating vibration patterns. It is shown in the experiments that the feedforward controller using optimised sensor locations reduces the radiated sound power by 7 dB, whereas the empirically placed sensors achieve only 4.5 dB. Furthermore, the potential of the proposed optimisation method regarding sound power reduction performance and the number of required sensors is shown for a real aircraft structure and a complex acoustic excitation.
引用
收藏
页码:361 / 372
页数:12
相关论文
共 27 条
  • [1] Algermissen S., 2012, P 23 INT C AD STRUCT
  • [2] [Anonymous], 2001, SIGNAL PROCESSING AC
  • [3] [Anonymous], 2007, Sound and Structural Vibration
  • [4] Active vibration control on a quarter-car for cancellation of road noise disturbance
    Belgacem, Walid
    Berry, Alain
    Masson, Patrice
    [J]. JOURNAL OF SOUND AND VIBRATION, 2012, 331 (14) : 3240 - 3254
  • [5] Comparison of structural-acoustic control designs on an active composite panel
    Bingham, B
    Atalla, MJ
    Hagood, NW
    [J]. JOURNAL OF SOUND AND VIBRATION, 2001, 244 (05) : 761 - 778
  • [6] Chipperfield A., 1994, GENETIC ALGORITHM TO
  • [7] A comparative study of methods for optimising sensor and actuator locations in active control applications
    De Fonseca, P
    Sas, P
    Van Brussel, H
    [J]. JOURNAL OF SOUND AND VIBRATION, 1999, 221 (04) : 651 - 679
  • [8] ADVANCED TURBOPROP NOISE PREDICTION BASED ON RECENT THEORETICAL RESULTS
    FARASSAT, F
    PADULA, SL
    DUNN, MH
    [J]. JOURNAL OF SOUND AND VIBRATION, 1987, 119 (01) : 53 - 79
  • [9] Frecker MI, 2003, J INTEL MAT SYST STR, V14, P207, DOI 10.1177/104538903031062
  • [10] CONTROL OF SOUND RADIATION WITH ACTIVE ADAPTIVE STRUCTURES
    FULLER, CR
    ROGERS, CA
    ROBERTSHAW, HH
    [J]. JOURNAL OF SOUND AND VIBRATION, 1992, 157 (01) : 19 - 39