Mass Measurement and Top-Down HPLC/MS Analysis of Intact Monoclonal Antibodies on a Hybrid Linear Quadrupole Ion Trap-Orbitrap Mass Spectrometer

被引:120
|
作者
Bondarenko, Pavel V. [1 ]
Second, Tonya P. [2 ]
Zabrouskov, Vlad [2 ]
Makarov, Alexander A. [3 ]
Zhang, Zhongqi
机构
[1] Amgen Inc, Dept Pharmaceut, Thousand Oaks, CA 91320 USA
[2] Thermo Fisher, San Jose, CA USA
[3] Thermo Fisher, Bremen, Germany
关键词
LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY; IMMUNOGLOBULIN-GAMMA-ANTIBODIES; STRUCTURAL-CHARACTERIZATION; PROTEIN; SITES; PHARMACEUTICS; DEAMIDATION; STABILITY; ISOFORMS; RECEPTOR;
D O I
10.1016/j.jasms.2009.03.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mass and top-down analyses of 150-kDa monoclonal immunoglobulin gamma (IgG) antibodies were performed on an Orbitrap analyzer. Three different sample delivery methods were tested including (1) infusion of an off-line desalted IgG sample using nano-electrospray; (2) on-line desalting followed by a step elution with a high percentage of organic solvent; and (3) reversed-phase HPLC separation and on-line mass and top-down analyses of disulfide isoforms of an IgG2 antibody. The accuracy of mass measurements of intact antibody was within +/-2 Da (15 ppm). The glycoforms of intact IgG antibodies separated by 162 Da were baseline resolved. In-source fragmentation of the intact antibodies produced mainly 115 residue fragments including N-terminal variable domains of heavy and light chains. The sequence coverage (the number of cleavages) was greatly increased after reduction of disulfide bonds and HPLC/MS/MS analysis of light and heavy chains using collision-induced dissociation in the ion trap of the LTQ-Orbitrap. This is an attractive alternative to peptide mapping for characterization and monitoring of post-translational modifications attributed to minimal sample preparation, high speed of the mass/top-down analysis, and relatively minor method-induced sample modifications. (J Am Soc Mass Spectrom 2009, 20, 1415-1424) (C) 2009 Published by Elsevier Inc. on behalf of American Society for Mass Spectrometry
引用
收藏
页码:1415 / 1424
页数:10
相关论文
共 50 条
  • [1] Top-down protein sequencing and MS3 on a hybrid linear quadrupole ion trap-orbitrap mass spectrometer
    Macek, B
    Waanders, LF
    Olsen, JV
    Mann, M
    MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (05) : 949 - 958
  • [2] Implementation of electron-transfer dissociation on a hybrid linear ion trap-orbitrap mass spectrometer
    McAlister, Graeme C.
    Phanstiel, Doug
    Good, David M.
    Berggren, W. Travis
    Coon, Joshua J.
    ANALYTICAL CHEMISTRY, 2007, 79 (10) : 3525 - 3534
  • [3] Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer
    Erickson, Brian K.
    Jedrychowski, Mark P.
    McAlister, Graeme C.
    Everley, Robert A.
    Kunz, Ryan
    Gygi, Steven P.
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1241 - 1249
  • [4] Comprehensive Lipidome Analysis by Shotgun Lipidomics on a Hybrid Quadrupole-Orbitrap-Linear Ion Trap Mass Spectrometer
    Almeida, Reinaldo
    Pauling, Josch Konstantin
    Sokol, Elena
    Hannibal-Bach, Hans Kristian
    Ejsing, Christer S.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2015, 26 (01) : 133 - 148
  • [5] Relative quantification of stable isotope labeled peptides using a linear ion trap-orbitrap hybrid mass spectrometer
    Venable, John D.
    Wohlschlegel, James
    McClatchy, Daniel B.
    Park, Sung Kyu
    Yates, John R., III
    ANALYTICAL CHEMISTRY, 2007, 79 (08) : 3056 - 3064
  • [6] Dual electrospray ion source for electron-transfer dissociation on a hybrid linear ion trap-orbitrap mass spectrometer
    Williams, D. Keith, Jr.
    McAlister, Graeme C.
    Good, David M.
    Coon, Joshua J.
    Muddiman, David C.
    ANALYTICAL CHEMISTRY, 2007, 79 (20) : 7916 - 7919
  • [7] Direct Peel Monitoring of Xenobiotics in Fruit by Direct Analysis in Real Time Coupled to a Linear Quadrupole Ion Trap-Orbitrap Mass Spectrometer
    Farre, Marinella
    Pico, Yolanda
    Barcelo, Damia
    ANALYTICAL CHEMISTRY, 2013, 85 (05) : 2638 - 2644
  • [8] A proteomics grade electron transfer dissociation-enabled hybrid linear ion trap-orbitrap mass spectrometer
    McAlister, Graeme C.
    Berggren, W. Travis
    Griep-Raming, Jens
    Horning, Stevan
    Makarov, Alexander
    Phanstiel, Doug
    Stafford, George
    Swaney, Danielle L.
    Syka, John E. P.
    Zabrouskov, Vlad
    Coon, Joshua J.
    JOURNAL OF PROTEOME RESEARCH, 2008, 7 (08) : 3127 - 3136
  • [9] Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer
    Makarov, A
    Denisov, E
    Kholomeev, A
    Baischun, W
    Lange, O
    Strupat, K
    Horning, S
    ANALYTICAL CHEMISTRY, 2006, 78 (07) : 2113 - 2120
  • [10] Advancing Top-down Analysis of the Human Proteome Using a Benchtop Quadrupole-Orbitrap Mass Spectrometer
    Fornelli, Luca
    Durbin, Kenneth R.
    Fellers, Ryan T.
    Early, Bryan P.
    Greer, Joseph B.
    LeDuc, Richard D.
    Compton, Philip D.
    Kelleher, Neil L.
    JOURNAL OF PROTEOME RESEARCH, 2017, 16 (02) : 609 - 618