Defining Prolonged Dwell Time: When Are Advanced Inferior Vena Cava Filter Retrieval Techniques Necessary? An Analysis in 762 Procedures

被引:38
作者
Desai, Kush R. [1 ]
Laws, James L. [1 ]
Salem, Riad [1 ]
Mouli, Samdeep K. [1 ]
Errea, Martin F. [1 ]
Karp, Jennifer K. [1 ]
Yang, Yihe [1 ]
Ryu, Robert K. [2 ]
Lewandowski, Robert J. [1 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 676 N St Clair St,Suite 800, Chicago, IL 60611 USA
[2] Univ Colorado, Sch Med, Dept Radiol, Aurora, CO USA
关键词
humans; pulmonary embolism; risk factors; vena cava filters; venous thrombosis; GUNTHER-TULIP; ASSISTED REMOVAL; COMPLICATIONS; OUTCOMES; EMBOLIZATION; PERMANENT; FRACTURE; SHEATH; CELECT;
D O I
10.1161/CIRCINTERVENTIONS.116.003957
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Despite growth in placement of retrievable inferior vena cava filters, retrieval rates remain low. Filters with extended implantation times present a challenge to retrieval, where standard techniques often fail. The development of advanced retrieval techniques has positively impacted retrieval of retrievable inferior vena cava filters with prolonged dwell times; however, there is no precise definition of the time point when advanced techniques become necessary. We aim to define prolonged retrievable inferior vena cava filters dwell time by determining the inflection point when the risk of standard retrieval technique failure increases significantly, necessitating advanced retrieval techniques to maintain overall technical success of retrieval. Methods and Results-From January 2009 to April 2015, 762 retrieval procedures were identified from a prospectively acquired database. We assessed patient age/sex, filter dwell time, procedural technical success, the use of advanced techniques, and procedure-related adverse events. Overall retrieval success rate was 98% (n=745). When standard retrieval techniques failed, advanced techniques were used; this was necessary 18% of the time (n=138). Logistic regression identified that dwell time was the only risk factor for failure of standard retrieval technique (odds ratio, 1.08; 95% confidence interval, 1.05-1.10; P<0.001). Spline function regression analysis demonstrated that if dwell time exceeded 7 months, the risk of standard technique failure was 40.9%. Adverse events occurred at a rate of 2% (n=18; 15 minor and 3 major). Conclusions-The necessity of advanced techniques to maintain technical success of retrieval increases with dwell time. Patients with retrievable inferior vena cava filters in place beyond 7 months may benefit from referral to centers with expertise in advanced filter retrieval.
引用
收藏
页数:5
相关论文
共 33 条
[1]  
Administration USFaD, REM RETR INF VEN CAV
[2]   Inferior Vena Cava Filter Retrieval: Effectiveness and Complications of Routine and Advanced Techniques [J].
Al-Hakim, Ramsey ;
Kee, Stephen T. ;
Olinger, Kristen ;
Lee, Edward W. ;
Moriarty, John M. ;
McWilliams, Justin P. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (06) :933-939
[3]   Comparison of Complication Rates Associated with Permanent and Retrievable Inferior Vena Cava Filters: A Review of the MAUDE Database [J].
Andreoli, Jessica M. ;
Lewandowski, Robert J. ;
Vogelzang, Robert L. ;
Ryu, Robert K. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (08) :1181-1185
[4]   Systematic Review of the Use of Retrievable Inferior Vena Cava Filters [J].
Angel, Luis F. ;
Tapson, Victor ;
Galgon, Richard E. ;
Restrepo, Marcos I. ;
Kaufman, John .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (11) :1522-1530
[5]   Technical and Patient-related Characteristics Associated with Challenging Retrieval of Inferior Vena Cava Filters [J].
Avgerinos, E. D. ;
Bath, J. ;
Stevens, J. ;
McDaniel, B. ;
Marone, L. ;
Dillavou, E. ;
Cho, J. S. ;
Makaroun, M. S. ;
Chaer, R. A. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (03) :353-359
[6]   A 16-F Sheath with Endobronchial Forceps Improves Reported Retrieval Success of Long-Dwelling "Closed Cell" Inferior Vena Cava Filter Designs [J].
Chick, Jeffrey Forris Beecham ;
Stavropoulos, S. William ;
Shin, Benjamin J. ;
Shlansky-Goldberg, Richard D. ;
Mondschein, Jeffrey I. ;
Sudheendra, Deepak ;
Nadolski, Gregory J. ;
Watts, Micah M. ;
Trerotola, Scott O. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 27 (07) :1027-1033
[7]   Eight-year follow-up of patients with permanent vena cava filters in the prevention of pulmonary embolism - The PREPIC (Prevention du Risque d'Embolie Pulmonaire par Interruption Cave) randomized study [J].
Decousus, H ;
Barral, FG ;
Buchmuller-Cordier, A ;
Charbonnier, B ;
Girard, P ;
Lamer, C ;
Laporte, A ;
Leizorovicz, A ;
Mismetti, P ;
Parent, F ;
Quenet, S ;
Rivron-Guillot, K ;
Tardy, B .
CIRCULATION, 2005, 112 (03) :416-422
[8]   A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis [J].
Decousus, H ;
Leizorovicz, A ;
Parent, F ;
Page, Y ;
Tardy, B ;
Girard, P ;
Laporte, S ;
Faivre, R ;
Charbonnier, B ;
Barral, FG ;
Huet, Y ;
Simonneau, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (07) :409-415
[9]   Retrieval of Inferior Vena Cava Filters With Prolonged Dwell Time: A Single-Center Experience in 648 Retrieval Procedures [J].
Desai, Kush R. ;
Lewandowski, Robert J. ;
Salem, Riad ;
Mouli, Samdeep K. ;
Karp, Jennifer K. ;
Laws, James L. ;
Ryu, Robert K. .
JAMA INTERNAL MEDICINE, 2015, 175 (09) :1572-1574
[10]   Complications of indwelling retrievable versus permanent inferior vena cava filters [J].
Desai, Tina R. ;
Morcos, Omar C. ;
Lind, Benjamin B. ;
Schindler, Nancy ;
Caprini, Joseph A. ;
Hahn, David ;
Warner, David ;
Gupta, NavYash .
JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2014, 2 (02) :166-172