Ionophore-Based Voltammetric Ion Activity Sensing with Thin Layer Membranes

被引:66
作者
Cuartero, Maria [1 ]
Crespo, Gaston A. [1 ]
Bakker, Eric [1 ]
机构
[1] Univ Geneva, Dept Inorgan & Analyt Chem, Quai Ernest Ansermet 30, CH-1211 Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
COMPLEX-FORMATION CONSTANTS; SELECTIVE ELECTRODES; POLYMERIC MEMBRANES; LIQUID-MEMBRANE; FILMS; COEFFICIENTS; RESPONSES; BLOOD;
D O I
10.1021/acs.analchem.5b03611
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As shown in recent work, thin layer ion-selective multi-ionophore membranes can be interrogated by cyclic voltammetry to detect the ion activity of multiple species simultaneously and selectively. Additional fundamental evidence is put forward on ion discrimination with thin multi-ionophore-based membranes with thicknesses of 200 +/- 25 nm and backside contacted with poly-3-octylthiophene (POT). An anodic potential scan partially oxidizes the POT film (to POT+), thereby initiating the release of hydrophilic cations from the membrane phase to the sample solution at a characteristic potential. Varying concentration of added cation-exhanger demonstrates that it limits the ion transfer charge and not the deposited POT film. Voltammograms with multiple peaks are observed with each associated with the transfer of one type of ion (lithium, potassium, and sodium). Experimental conditions (thickness and composition of the membrane and concentration of the sample) are chosen that allow one to describe the system by a thermodynamic rather than kinetic model. As a consequence, apparent stability constants for sodium, potassium, and lithium (assuming 1:1 stoichiometry) with their respective ionophores are calculated and agree well with the values obtained by the potentiometric sandwich membrane technique. As an analytical application, a membrane containing three ionophores was used to determine lithium, sodium, and potassium in artificial samples at the same location and within a single voltammetric scan. Lithium and potassium were also determined in undiluted human plasma in the therapeutic concentration range.
引用
收藏
页码:1654 / 1660
页数:7
相关论文
共 26 条
[21]   Determination of complex formation constants of 18 neutral alkali and alkaline earth metal ionophores in poly(vinyl chloride) sensing membranes plasticized with bis(2-ethylhexyl)sebacate and o-nitrophenyloctylether [J].
Qin, Y ;
Mi, YM ;
Bakker, E .
ANALYTICA CHIMICA ACTA, 2000, 421 (02) :207-220
[22]   Quantification of the concentration of ionic impurities in polymeric sensing membranes with the segmented sandwich technique [J].
Qin, Y ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2001, 73 (17) :4262-4267
[23]   Conducting polymer polypyrrole supported bilayer lipid membranes [J].
Shao, Y ;
Jin, YD ;
Wang, JL ;
Wang, L ;
Zhao, F ;
Dong, SJ .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (07) :1373-1379
[24]   Thin layer electrochemical extraction of non-redoxactive cations with an anion-exchanging conducting polymer overlaid with a selective membrane [J].
Si, Pengchao ;
Bakker, Eric .
CHEMICAL COMMUNICATIONS, 2009, (35) :5260-5262
[25]   SELECTIVITY COEFFICIENTS FOR ION-SELECTIVE ELECTRODES - RECOMMENDED METHODS FOR REPORTING K-A,B(POT) VALUES - (TECHNICAL REPORT) [J].
UMEZAWA, Y ;
UMEZAWA, K ;
SATO, H .
PURE AND APPLIED CHEMISTRY, 1995, 67 (03) :507-518
[26]   Voltammetric Ion-Selective Electrodes for the Selective Determination of Cations and Anions [J].
Zhang, Jie ;
Harris, Alexander R. ;
Cattrall, Robert W. ;
Bond, Allan M. .
ANALYTICAL CHEMISTRY, 2010, 82 (05) :1624-1633