A desalting approach for MALDI-MS using on-probe hydrophobic self assembled monolayers

被引:77
|
作者
Brockman, AH
Dodd, BS
Orlando, N
机构
[1] UNIV GEORGIA,COMPLEX CARBOHYDRATE RES CTR,ATHENS,GA 30602
[2] UNIV GEORGIA,DEPT BIOCHEM & MOL BIOL,ATHENS,GA 30602
[3] UNIV GEORGIA,DEPT CHEM,ATHENS,GA 30602
关键词
D O I
10.1021/ac970650u
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One of the problems encountered in preparing samples for matrix-assisted laser desorption/ionization (MALDI) analysis is the presence of nonvolatile salts in the sample, This difficulty is often exacerbated by the necessity to prepare the sample in the appropriate sample-to-matrix ratio, This paper reports a probe surface derivatization method that greatly simplifies this sample preparation process, By constructing self-assembled monolayers of octadecyl mercaptan (C18) on the MALDI probe surface, we were able to generate a surface capable of reversibly binding polypeptides via hydrophobic interactions, which in turn, permits the analyte to be easily concentrated and desalted directly on the probe tip.
引用
收藏
页码:4716 / 4720
页数:5
相关论文
共 50 条
  • [1] On-probe digestion of bacterial proteins for MALDI-MS
    Harris, WA
    Reilly, JP
    ANALYTICAL CHEMISTRY, 2002, 74 (17) : 4410 - 4416
  • [2] Non-specific, on-probe cleanup methods for MALDI-MS samples
    Xu, YD
    Bruening, ML
    Watson, JT
    MASS SPECTROMETRY REVIEWS, 2003, 22 (06) : 429 - 440
  • [3] On-probe immunoassay by MALDI MS.
    Liang, XL
    Zheng, KF
    Lubman, DM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 103 - ANYL
  • [4] On-probe solid-phase extraction MALDI-MS using ion-pairing interactions for the cleanup of peptides and proteins
    Warren, ME
    Brockman, AH
    Orlando, R
    ANALYTICAL CHEMISTRY, 1998, 70 (18) : 3757 - 3761
  • [5] MALDI-MS of hydrophobic and hydrophilic peptides.
    Breaux, G
    Green-Church, KB
    Limbach, PA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 218 : U266 - U266
  • [6] One-step on-plate desalting protocol for MALDI-MS; Using hydrophobic polymer micro-contact printing technique
    Lu, H.
    Yang, P.
    MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (10) : S153 - S153
  • [7] Increasing Surface Capacity for On-Probe Affinity Capture MALDI-MS via Gold Particle Attachment to Allyl Amine Plasma Polymers
    Segu, Zaneer M.
    Timmons, Richard B.
    Kinsel, Gary R.
    ANALYTICAL CHEMISTRY, 2011, 83 (07) : 2500 - 2504
  • [8] Performances of protein array platforms prepared by soft lithography and self-assemblying monolayers-approach by using SPR, ellipsometry and MALDI-MS
    Hamaloglu, Kadriye Ozlem
    Celikbicak, Omur
    Salih, Bekir
    Piskin, Erhan
    JOURNAL OF MOLECULAR STRUCTURE, 2019, 1198
  • [9] Complementary analysis of lipids in whole bacteria cells by thermally assisted hydrolysis and methylation-GC and MALDI-MS combined with on-probe sample pretreatment
    Ishida, Yasuyuki
    Kitagawa, Kuniyuki
    Nakayama, Akihito
    Ohtani, Hajime
    JOURNAL OF ANALYTICAL AND APPLIED PYROLYSIS, 2006, 77 (02) : 116 - 120
  • [10] Complementary analysis of lipids in whole bacteria cells by thermally assisted hydrolysis and methylation-GC and MALDI-MS combined with on-probe sample pretreatment
    Ishida, Yasuyuki
    Kitagawa, Kuniyuki
    Nakayama, Akihito
    Ohtani, Hajime
    Journal of Analytical and Applied Pyrolysis, 2006, 77 (02): : 116 - 120