Intraocular lens power formula based on vergence calculation and lens design

被引:26
作者
Naeser, K
机构
[1] Department of Ophthalmology, 9100 Aalborg, Aalborg Sygehus Syd
关键词
D O I
10.1016/S0886-3350(97)80316-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To present a new method of intraocular lens (IOL) power calculation that takes into account the power-dependent variation in lens design. Setting: Department of Ophthalmology, Aalborg, Denmark. Methods: Information on exact IOL design is derived from the manufacturers' cutting cards. These data were built into an IOL calculation formula based on exact ray tracing and vergence calculation. All algorithms are demonstrated. Results: The method is optically correct as all refractive surfaces are characterized with respect to both position and refractive power. In simulation models, the Naeser and the Holladay formulas performed similarly, while the SRK/T formula predicted higher postoperative refractions for low-power IOLs. Conclusion: It is possible to incorporate the exact IOL design into an IOL power calculation formula. Theoretically, the Naeser formula should increase the accuracy of IOL power calculation; however, this has yet to be proved from empirical data. The formula provides an advantage in analysis of postoperative pseudophakia for experimental/scientific purposes because all intraocular distances and powers may be measured or calculated.
引用
收藏
页码:1200 / 1207
页数:8
相关论文
共 19 条
[1]  
ARMITAGE P, 1987, STATISTICAL METHODS, P141
[3]  
Binkhorst RD., 1981, Intraocular Lens Power Calculation Manual. A Guide to the Author's TI 58/59 IOL Power Module, V2nd
[4]   VAULTED POSTERIOR CHAMBER LENSES AND THE POSTERIOR CAPSULE [J].
BOBERGANS, LJ ;
NAESER, K ;
BARGUM, R .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03) :325-328
[5]  
HAIGIS W, 1990, EUR J IMPLANT REFRAC, V2, P191
[6]   A 3-PART SYSTEM FOR REFINING INTRAOCULAR-LENS POWER CALCULATIONS [J].
HOLLADAY, JT ;
PRAGER, TC ;
CHANDLER, TY ;
MUSGROVE, KH ;
LEWIS, JW ;
RUIZ, RS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (01) :17-24
[7]  
NAESER K, 1986, ACTA OPHTHALMOL, V64, P323
[8]   BIOMETRY OF THE POSTERIOR LENS CAPSULE - A NEW METHOD TO PREDICT PSEUDOPHAKIC ANTERIOR-CHAMBER DEPTH [J].
NAESER, K ;
BOBERGANS, J ;
BARGUM, R .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (02) :202-206
[9]  
NAESER K, 1988, ACTA OPHTHALMOL, V66, P433
[10]   CALCULATION OF THE THICKNESS OF AN INTRAOCULAR-LENS [J].
NAESER, K ;
NAESER, EV .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01) :40-42