Reliability of echocardiographic measurements of left cardiac structures in healthy children

被引:31
|
作者
Geelhoed, Miranda J. J. [1 ,2 ,3 ]
Snijders, Sonja P. E. [1 ]
Kleyburg-Linkers, Veronica E. [1 ]
Steegers, Eric A. P. [4 ]
van Osch-Gevers, Lennie [3 ]
Jaddoe, Vincent W. V. [1 ,2 ,3 ]
机构
[1] Erasmus MC, Generat R Study Grp, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Epidemiol, NL-3000 CA Rotterdam, Netherlands
[3] Erasmus MC, Dept Pediat, NL-3000 CA Rotterdam, Netherlands
[4] Erasmus MC, Dept Obstet & Gynecol, NL-3000 CA Rotterdam, Netherlands
关键词
Cardiac dimensions; ultrasound; children; intraobserver/interobserver variability; RENAL LENGTH; INTEROBSERVER; VARIABILITY;
D O I
10.1017/S1047951109990862
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Echocardiographic measurements are widely used as outcomes of different studies. The aim of this study was to assess intraobserver and interobserver reliability of echocardiographic measurements in healthy children. Materials and methods: We studied 28 children, with a median age of 7.5 years, and inter-quartile range from 3 to 11 years. Intraobserver and interobserver reliability were assessed by repeated measurements of the diameters of the aortic root, the left atrium, and left ventricular end-diastolic structure. We also measured the ventricular end-diastolic septal thickness and the end-diastolic thickness of the left ventricular posterior wall. We calculated intraclass correlation coefficients, with corresponding 95% confidence intervals, and computed Bland and Altman plots, permitting us to derive limits of agreement plus or minus 2 standard deviations for the mean differences in cardiac measurements. Results: We found high intraobserver and interobserver intraclass correlation coefficient, ranging from 0.91 for ventricular septal thickness, with 9596 confidence intervals from 0.78 to 0.96, to 0.99 for the diameter of the aortic root, 95%, confidence interval from 0.97 to 1.00. Limits of agreement in the Bland and Altman plots ranged from zero millimetres for left ventricular end-diastolic posterior wall thickness to 1.60 millimeters (6.396) for left atrial diameter. Conclusions: Our study demonstrated good repeatability and reproducibility for ultrasonic measurements of left cardiac structures in children, showing that values obtained for measurement of these structures in both clinical and epidemiological research projects can be confidently accepted.
引用
收藏
页码:494 / 500
页数:7
相关论文
共 50 条
  • [21] CARDIAC-FUNCTION IN HEALTHY INFANTS AND CHILDREN - DOPPLER-ECHOCARDIOGRAPHIC EVALUATION
    HANSEUS, K
    BJORKHEM, G
    LUNDSTROM, NR
    PEDIATRIC CARDIOLOGY, 1994, 15 (05) : 211 - 218
  • [22] Comparison of echocardiographic measurements and cardiac biomarkers in healthy dogs eating nontraditional or traditional diets
    Owens, Eric J.
    LeBlanc, Nicole L.
    Freeman, Lisa M.
    Scollan, Katherine F.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2023, 37 (01) : 37 - 46
  • [23] Reliability of echocardiographic measurements of left ventricular systolic function in potential pediatric heart transplant donors
    Chen, Sharon
    Tierney, Elif Seda Selamet
    Khush, Kiran K.
    John Nguyen
    Goldstein, Benjamin A.
    May, Lindsay J.
    Hollander, Seth A.
    Kaufman, Beth D.
    Rosenthal, David N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (01): : 100 - 106
  • [24] Palmar Abduction Measurements: Reliability and Introduction of Normative Data in Healthy Children
    de Kraker, Marjolein
    Selles, Ruud W.
    Molenaar, Ties M.
    Schreuders, Ton A.
    Hovius, Sreven E.
    Stam, Henk J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (09): : 1704 - 1708
  • [25] Reference values for echocardiographic measurements of healthy newborns
    Guzeltas, Alper
    Eroglu, Ayse Guler
    CARDIOLOGY IN THE YOUNG, 2012, 22 (02) : 152 - 157
  • [26] ECHOCARDIOGRAPHIC DETERMINATION OF LEFT-VENTRICULAR MASS IN CARDIAC AMYLOIDOSIS - COMPARISON WITH POSTMORTEM MASS MEASUREMENTS
    ALLERI, MR
    FOLEY, DA
    TAJIK, AJ
    CIRCULATION, 1992, 86 (04) : 447 - 447
  • [27] REPRODUCIBILITY OF ECHOCARDIOGRAPHIC LEFT-VENTRICULAR MEASUREMENTS
    WALLERSON, DC
    DEVEREUX, RB
    HYPERTENSION, 1987, 9 (02) : 6 - 18
  • [28] Limited Relationship Between Echocardiographic Measures and Electrocardiographic Markers of Left Ventricular Size in Healthy Children
    Alexander, Mark E.
    Gongwer, Russell
    Trachtenberg, Felicia L.
    Minich, L. LuAnn
    Triedman, John K.
    Kaltman, Jonathan R.
    Czosek, Richard J.
    Tristani-Firouzi, Martin
    Lapage, Martin J.
    Tsao, Sabrina S.
    Radbill, Andrew E.
    Dilorenzo, Michael P.
    Kovach, Joshua R.
    Stephenson, Elizabeth A.
    Janson, Christopher
    Mao, Chad
    Salerno, Jack C.
    Clark, Bradley C.
    Mahgerefteh, Joseph
    Pilcher, Thomas
    Johnson, Tiffanie R.
    Kim, Jeff J.
    Valdes, Santiago O.
    Cain, Nicole
    Jackson, Lanier
    Saarel, Elizabeth V.
    PEDIATRIC CARDIOLOGY, 2024, 45 (05) : 1159 - 1160
  • [29] Limited Relationship Between Echocardiographic Measures and Electrocardiographic Markers of Left Ventricular Size in Healthy Children
    Mark E. Alexander
    Russell Gongwer
    Felicia L. Trachtenberg
    L. LuAnn Minich
    John K. Triedman
    Jonathan R. Kaltman
    Richard J. Czosek
    Martin Tristani-Firouzi
    Martin J. LaPage
    Sabrina S. Tsao
    Andrew E. Radbill
    Michael P. DiLorenzo
    Joshua R. Kovach
    Elizabeth A. Stephenson
    Christopher Janson
    Chad Mao
    Jack C. Salerno
    Bradley C. Clark
    Joseph Mahgerefteh
    Thomas Pilcher
    Tiffanie R. Johnson
    Jeff J. Kim
    Santiago O. Valdes
    Nicole Cain
    Lanier Jackson
    Elizabeth V. Saarel
    Pediatric Cardiology, 2024, 45 : 1055 - 1063
  • [30] A comparison of the effects of indexation on standard echocardiographic measurements of the left heart in a healthy multi-racial population
    Katrina K. Poppe
    Robert N. Doughty
    Helen J. Walsh
    Christopher M. Triggs
    Gillian A. Whalley
    The International Journal of Cardiovascular Imaging, 2014, 30 : 749 - 758