Reliability of echocardiographic measurements of left cardiac structures in healthy children

被引:31
|
作者
Geelhoed, Miranda J. J. [1 ,2 ,3 ]
Snijders, Sonja P. E. [1 ]
Kleyburg-Linkers, Veronica E. [1 ]
Steegers, Eric A. P. [4 ]
van Osch-Gevers, Lennie [3 ]
Jaddoe, Vincent W. V. [1 ,2 ,3 ]
机构
[1] Erasmus MC, Generat R Study Grp, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Epidemiol, NL-3000 CA Rotterdam, Netherlands
[3] Erasmus MC, Dept Pediat, NL-3000 CA Rotterdam, Netherlands
[4] Erasmus MC, Dept Obstet & Gynecol, NL-3000 CA Rotterdam, Netherlands
关键词
Cardiac dimensions; ultrasound; children; intraobserver/interobserver variability; RENAL LENGTH; INTEROBSERVER; VARIABILITY;
D O I
10.1017/S1047951109990862
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Echocardiographic measurements are widely used as outcomes of different studies. The aim of this study was to assess intraobserver and interobserver reliability of echocardiographic measurements in healthy children. Materials and methods: We studied 28 children, with a median age of 7.5 years, and inter-quartile range from 3 to 11 years. Intraobserver and interobserver reliability were assessed by repeated measurements of the diameters of the aortic root, the left atrium, and left ventricular end-diastolic structure. We also measured the ventricular end-diastolic septal thickness and the end-diastolic thickness of the left ventricular posterior wall. We calculated intraclass correlation coefficients, with corresponding 95% confidence intervals, and computed Bland and Altman plots, permitting us to derive limits of agreement plus or minus 2 standard deviations for the mean differences in cardiac measurements. Results: We found high intraobserver and interobserver intraclass correlation coefficient, ranging from 0.91 for ventricular septal thickness, with 9596 confidence intervals from 0.78 to 0.96, to 0.99 for the diameter of the aortic root, 95%, confidence interval from 0.97 to 1.00. Limits of agreement in the Bland and Altman plots ranged from zero millimetres for left ventricular end-diastolic posterior wall thickness to 1.60 millimeters (6.396) for left atrial diameter. Conclusions: Our study demonstrated good repeatability and reproducibility for ultrasonic measurements of left cardiac structures in children, showing that values obtained for measurement of these structures in both clinical and epidemiological research projects can be confidently accepted.
引用
收藏
页码:494 / 500
页数:7
相关论文
共 50 条
  • [1] Regression equations for calculation of z scores for echocardiographic measurements of left heart structures in healthy Han Chinese children
    Wang, Shan-Shan
    Hong, Wen-Jing
    Zhang, Yu-Qi
    Chen, Shu-Bao
    Huang, Guo-Ying
    Zhang, Hong-Yan
    Chen, Li-Jun
    Wu, Lan-Ping
    Shen, Rong
    Liu, Yi-Qing
    Zhu, Jun-Xue
    JOURNAL OF CLINICAL ULTRASOUND, 2018, 46 (05) : 328 - 333
  • [2] Echocardiographic measurements of cardiac structures: comparison with pathoanatomy
    Gerger, D.
    Grassberger, M.
    Stoellberger, C.
    Weidinger, F.
    Feichtinger, H.
    WIENER KLINISCHE WOCHENSCHRIFT, 2013, 125 : S57 - S57
  • [3] Reliability of echocardiographic measurements in young, healthy adult males.
    Gates, PE
    George, KP
    Campbell, IG
    FASEB JOURNAL, 2001, 15 (05): : A793 - A793
  • [4] ECHOCARDIOGRAPHIC MEASUREMENTS OF LEFT-VENTRICLE IN NORMAL INFANTS AND CHILDREN
    AKIBA, T
    YOSHIKAWA, M
    OTAKI, S
    KOBAYASHI, Y
    NAKASATO, M
    SUZUKI, H
    SATO, T
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1986, 149 (01): : 31 - 37
  • [5] Regression Equations for Calculation of z Scores for Echocardiographic Measurements of Right Heart Structures in Healthy Han Chinese Children
    Wang, Shan-Shan
    Zhang, Yu-Qi
    Chen, Shu-Bao
    Huang, Guo-Ying
    Zhang, Hong-Yan
    Zhang, Zhi-Fang
    Wu, Lan-Ping
    Hong, Wen-Jing
    Shen, Rong
    Liu, Yi-Qing
    Zhu, Jun-Xue
    JOURNAL OF CLINICAL ULTRASOUND, 2017, 45 (05) : 293 - 303
  • [6] Reliability of mandibular range of motion measurements in healthy children
    de Sonnaville, Willemijn F. C.
    Steenks, Michel H.
    Verkouteren, Daan R. C.
    Zuithoff, Nicolaas P. A.
    Wulffraat, Nico M.
    Rosenberg, Antoine J. W. P.
    Speksnijder, Caroline M.
    JOURNAL OF ORAL REHABILITATION, 2024, 51 (10) : 1973 - 1980
  • [7] Establishing norms for echocardiographic measurements of cardiovascular structures and function in children
    Lipshultz, SE
    Miller, TL
    JOURNAL OF APPLIED PHYSIOLOGY, 2005, 99 (02) : 386 - 388
  • [8] Comparison of two-dimensional echocardiographic measurements of the left atrium in healthy dogs
    Hetyey, C
    Vörös, K
    Reiczigel, J
    ACTA VETERINARIA HUNGARICA, 2005, 53 (01) : 23 - 33
  • [9] Influence of alterations in heart rate on left ventricular echocardiographic measurements in healthy cats
    Sugimoto, Keisuke
    Fujii, Yoko
    Ogura, Yuto
    Sunahara, Hiroshi
    Aoki, Takuma
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2017, 19 (08) : 841 - 845
  • [10] Discrepancies between echocardiographic measurements of left ventricular mass in a healthy adult population
    Deague, JA
    Wilson, CM
    Grigg, LE
    Harrap, SB
    CLINICAL SCIENCE, 1999, 97 (03) : 377 - 383