Chlorhexidine gluconate transparent dressing does not decrease central line-associated bloodstream infection in critically ill patients: A randomized controlled trial

被引:1
作者
Yu, Kunrong [1 ]
Lu, Meishan [2 ]
Meng, Yanling [3 ]
Zhao, Yanwei [4 ]
Li, Zheng [5 ]
机构
[1] Peking Union Med Coll & Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Pulm & Crit Care Med Ward, Beijing, Peoples R China
[2] Peking Union Med Coll & Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Hlth Care, 1 Shuaifuyuan, Beijing 100730, Peoples R China
[3] Peking Union Med Coll & Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Med ICU, Beijing, Peoples R China
[4] Peking Union Med Coll & Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Nursing, Beijing, Peoples R China
[5] Peking Union Med Coll, Sch Nursing, Beijing, Peoples R China
关键词
central line-associated bloodstream infections; chlorhexidine; critical care; dressing; nursing; CATHETER-RELATED INFECTIONS; INTENSIVE-CARE UNITS; SAFETY NETWORK; PREVENTION; GUIDELINES; PROGRAM; ADULTS; RATES;
D O I
10.1111/ijn.12776
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Background Central line-associated blood stream infections are accompanied by increased mortality and health care costs. The application of different types of dressings in infection control has not been fully investigated to date. Aim To assess the effects of two different dressing types on central line-associated bloodstream infections. Methods A randomized, nonblinded, controlled trial was conducted. Central lines were randomly allocated to intervention (chlorhexidine gluconate transparent dressing, n = 259) and control groups (standard dressing, n = 215). The central line-associated bloodstream infection rate was assessed. Results A statistically nonsignificant difference was noted in the overall central line-associated bloodstream infection rates between the two groups. The frequency of dressing changes in the patients with the chlorhexidine gluconate transparent dressing was significantly lower than that in the patients with a standard dressing. The predominant type of infectious microorganisms isolated from the central line-associated bloodstream infection episodes was Gram-negative bacteria (57.2%). Gram-positive bacteria and fungi were noted at lower percentages (28.5% and 14.3%, respectively). Conclusion The use of a chlorhexidine gluconate transparent dressing does not decrease the central line-associated bloodstream infection rate, although it decreases the frequency of dressing changes so may save nursing time.
引用
收藏
页数:8
相关论文
共 27 条
[1]  
[Anonymous], 2009, J ASS VASCULAR ACCES, DOI DOI 10.2309/JAVA.14-4-5
[2]   Effectiveness of a catheter-associated bloodstream infection bundle in a Thai tertiary care center: A 3-year study [J].
Apisarnthanarak, Anucha ;
Thongphubeth, Kanokporn ;
Yuekyen, Chananart ;
Warren, David K. ;
Fraser, Victoria J. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2010, 38 (06) :449-455
[3]   'Matching Michigan': a 2-year stepped interventional programme to minimise central venous catheter-blood stream infections in intensive care units in England [J].
Bion, Julian ;
Comm, Writing ;
Richardson, Annette ;
Hibbert, Peter ;
Beer, Jeanette ;
Abrusci, Tracy ;
McCutcheon, Martin ;
Cassidy, Jane ;
Eddleston, Jane ;
Gunning, Kevin ;
Bellingan, Geoff ;
Patten, Mark ;
Harrison, David .
BMJ QUALITY & SAFETY, 2013, 22 (02) :110-123
[4]   Central line associated blood stream infection rate after intervention and comparing outcome with national healthcare safety network and international nosocomial infection control consortium data [J].
Bukhari, S. Z. ;
Banjar, A. ;
Baghdadi, S. S. ;
Baltow, B. A. ;
Ashshi, A. M. ;
Hussain, W. M. .
ANNALS OF MEDICAL AND HEALTH SCIENCES RESEARCH, 2014, 4 (05) :682-686
[5]  
Du B., 2001, CHINESE J CLIN, V7, P9, DOI [10.3969/j.issn.1008-1089.2001.07.005, DOI 10.3969/J.ISSN.1008-1089.2001.07.005]
[6]   National Healthcare Safety Network (NHSN) report, data summary for 2012, Device-associated module [J].
Dudeck, Margaret A. ;
Weiner, Lindsey M. ;
Allen-Bridson, Katherine ;
Malpiedi, Paul J. ;
Peterson, Kelly D. ;
Pollock, Daniel A. ;
Sievert, Dawn M. ;
Edwards, Jonathan R. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (12) :1148-1166
[7]   Central Line Bundle Implementation in US Intensive Care Units and Impact on Bloodstream Infections [J].
Furuya, E. Yoko ;
Dick, Andrew ;
Perencevich, Eli N. ;
Pogorzelska, Monika ;
Goldmann, Donald ;
Stone, Patricia W. .
PLOS ONE, 2011, 6 (01)
[8]   CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting [J].
Horan, Teresa C. ;
Andrus, Mary ;
Dudeck, Margaret A. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2008, 36 (05) :309-332
[9]   Clinical evaluation of a chlorhexidine intravascular catheter gel dressing on short-term central venous catheters [J].
Karpanen, Tarja J. ;
Casey, Anna L. ;
Whitehouse, Tony ;
Nightingale, Peter ;
Das, Ira ;
Elliott, Thomas S. J. .
AMERICAN JOURNAL OF INFECTION CONTROL, 2016, 44 (01) :54-60
[10]   The risk of bloodstream infection in adults with different intravascular devices: A systematic review of 200 published prospective studies [J].
Maki, Dennis G. ;
Kluger, Daniel M. ;
Crnich, Christopher J. .
MAYO CLINIC PROCEEDINGS, 2006, 81 (09) :1159-1171