Development and validation of a methodology based on Captiva EMR-lipid clean-up and LC-MS/MS analysis for the simultaneous determination of mycotoxins in human plasma

被引:36
作者
Arce-Lopez, Beatriz [1 ]
Lizarraga, Elena [1 ]
Flores-Flores, Myra [1 ]
Irigoyen, Angel [1 ]
Gonzalez-Penas, Elena [1 ]
机构
[1] Univ Navarra, Fac Pharm & Nutr, Pharmaceut Technol & Chem Dept, Res Grp MITOX, C Irunlarrea 1, Pamplona 31008, Navarra, Spain
关键词
Mycotoxins; Multi-detection; Human plasma; LC-MS/MS; Human biomonitoring; BIOLOGICAL MATRICES; MULTI-MYCOTOXIN; QUANTIFICATION;
D O I
10.1016/j.talanta.2019.120193
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report the methodology for the quantification of 19 mycotoxins in human plasma using high performance liquid chromatography-mass spectrometry (triple quadrupole). The studied mycotoxins were: deepoxy-deoxynivalenol, aflatoxins (B1, B2, G1, G2 and M1), T-2 and HT-2, ochratoxins A and B, zearalenone, sterigmatocystin, nivalenol, deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyldeoxynivalenol, neosolaniol, diacetoxyscirpenol and fusarenon-X. Sample deproteinization and cleanup were performed in one step using Captiva EMR-lipid (3 mL) cartridges and acetonitrile (with 1% formic acid). The extraction step was simple and fast. Validation was based on the evaluation of limits of detection (LOD) and quantification, linearity, precision, recovery, matrix effect, and stability. LOD values ranged from 0.04 ng/mL for aflatoxin B1 to 2.7 ng/mL for HT-2, except for nivalenol, which was 9.1 ng/mL. Recovery was obtained in intermediate precision conditions and at three concentration levels. Mean values ranged from 68.8% for sterigmatocystin to 97.6% for diacetoxyscirpenol (RDS <= 15% for all the mycotoxins). Matrix effects (assessed at three concentration levels and in intermediate conditions) were not significant for most of the mycotoxins and were between 75.4% for sterigmatocystin and 109.3% for ochratoxin B (RDS <= 15% for all the mycotoxins). This methodology will be useful in human bio-monitoring studies of mycotoxins for its reliability.
引用
收藏
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 2018, Bioanalytical method validation guidance for industry, V44
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], 2002, MONOGRAPHS EVALUATIO
[4]  
[Anonymous], [No title captured]
[5]  
[Anonymous], 2015, EFSA SUPP PUBL
[6]   Development of a Rapid LC-MS/MS Method for the Determination of Emerging Fusarium mycotoxins Enniatins and Beauvericin in Human Biological Fluids [J].
Belen Serrano, Ana ;
Capriotti, Anna Laura ;
Cavaliere, Chiara ;
Piovesana, Susy ;
Samperi, Roberto ;
Ventura, Salvatore ;
Lagana, Aldo .
TOXINS, 2015, 7 (09) :3554-3571
[7]   Quantitative determination of carcinogenic mycotoxins in human and animal biological matrices and animal-derived foods using multi-mycotoxin and analyte-specific high performance liquid chromatography-tandem mass spectrometric methods [J].
Cao, Xiaoqin ;
Li, Xiaofei ;
Li, Jian ;
Niu, Yunhui ;
Shi, Lu ;
Fang, Zhenfeng ;
Zhang, Tao ;
Ding, Hong .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1073 :191-200
[8]   Multiclass mycotoxin analysis in food, environmental and biological matrices with chromatography/mass spectrometry [J].
Capriotti, Anna Laura ;
Caruso, Giuseppe ;
Cavaliere, Chiara ;
Foglia, Patrizia ;
Samperi, Roberto ;
Lagana, Aldo .
MASS SPECTROMETRY REVIEWS, 2012, 31 (04) :466-503
[9]   Studies on the Presence of Mycotoxins in Biological Samples: An Overview [J].
Escriva, Laura ;
Font, Guillermina ;
Manyes, Lara ;
Berrada, Houda .
TOXINS, 2017, 9 (08)
[10]  
European Medicines Agency, 2012, GUIDELINE BIOANALYTI